• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Category 2 Parallel Operating Agreement
Category 2 Parallel Operating Agreement

RF Amplifier Output Voltage, Current, Power
RF Amplifier Output Voltage, Current, Power

... o For load impedances lower than the amplifier output impedance the amplifier is protected by the current limit. Regardless of how small the load is, the output current will not exceed a value near the specified minimum current rating. Again applying ohm’s law: Wattsnet  Ampsmin rating2  load and ...
Design and construction of a polygon
Design and construction of a polygon

... common coupling (PCC) and consequently resulting in undesired supply voltage conditions for costumers in the vicinity. The value of current harmonic components which are injected into the grid by nonlinear loads such as DTCIMD’s should be confined within the standard limitations. The most prominent ...
Modular Power Strip
Modular Power Strip

... allows for the connecting of international devices without needing a separate adapter (assuming the device supports the supplied voltage). We can also include specialized plugs like a USB charging block. Given that more and more mobile devices (cell phone, mp3 players, etc.) are charged through USB ...
Load Surge Management
Load Surge Management

Utility Static Var Compensator (SVC)
Utility Static Var Compensator (SVC)

... transfer capability of a transmission line. Reduction of harmonics Non-linear loads generate harmonic currents. The harmonic currents load the network and lead to voltage distortions. Distorted voltage may cause malfunctions in sensitive computerised devices and other process control equipment. The ...
Agilent AN 372-1 Power Supply Testing
Agilent AN 372-1 Power Supply Testing

... and a high degree of manual control for bench use. In contrast, power supply testing in production environments primarily focus on overall function based on the specifications determined during the products design phase. Automation is often essential due to large volume testing, which requires high ...
Full paper template_PEMD
Full paper template_PEMD

Reversible Current Power Supply for Fast-Field
Reversible Current Power Supply for Fast-Field

... a field of high flux density (BD) is applied, preferably, during a short period of time. Relaxometers are usually composed by a magnet, where the sample is put, an acquisition system, that is, most of the times a Radio-Frequency system, that sends periodic pulses, and the power supply, that should b ...
Research Article Matrix Converter Based Unified Power Quality
Research Article Matrix Converter Based Unified Power Quality

... the matrix converter output terminals to the load side through series transformer and the input side of matrix converter is connected to the supply side with step up transformer. So a matrix converter injects the compensation voltage on the load-side, so it is possible to mitigate the voltage sag/sw ...
Aalborg Universitet Connected Modes
Aalborg Universitet Connected Modes

... grid) or islanded (isolated from the utility grid) modes [1]. DGs often consist of a prime mover connected through an interface converter (e.g. an inverter in the case of dc-to-ac conversion) to the power distribution system (microgrid or utility grid). The main role of this inverter is to control v ...
Inside the Power Supply
Inside the Power Supply

... are ZERO. • The average voltage (dc) across a winding (neglecting winding resistance) is ALWAYS ZERO. This is one of the most useful facts in our bag of tools. ...
HARMONICS - Understanding the Facts
HARMONICS - Understanding the Facts

... system) then the harmonic currents will result in lower harmonic voltages than if the source impedance were high (such as found with some types of isolation transformers). Like any power quality investigation, the search can begin at the equipment effected by the problem or at the point-of-common-co ...
Performance Improvement in a DFIG - based Wind Farm
Performance Improvement in a DFIG - based Wind Farm

... The DFIG technology helps in extracting maximum energy from the wind even for low wind speeds by optimizing the turbine speed, and also minimizes mechanical stresses on the turbine during gusts of wind. One more advantage of the DFIG technology the power electronic converters are able to generate or ...
A New Harmonic Detection Method for Shunt Active
A New Harmonic Detection Method for Shunt Active

... According to (4), AC terms of d-q components are caused by harmonic components of load current. Thus, injection these currents with using another source, we can prevent harmonic current flowing in system power source. To achieve this purpose, ( currents should be transformed to a-b-c components Park ...
Kostakis-etal-EST2017-Fast-acting-protection-as-a-key-enabler
Kostakis-etal-EST2017-Fast-acting-protection-as-a-key-enabler

AN-376 Logic-System Design Techniques Reduce Switching
AN-376 Logic-System Design Techniques Reduce Switching

1C.4.1—Harmonic Distortion
1C.4.1—Harmonic Distortion

... Harmonic distortion is commonly produced by customer equipment injecting electrical noise into the power system. This will degrade PacifiCorp’s service to other customers. Maintaining electrical noise within tolerable limits will allow PacifiCorp to provide quality electrical service to all its cust ...
TESTING READINESS REVIEW T I R
TESTING READINESS REVIEW T I R

... minutes represents a by Ball) window Heaters are not necessary Accelerometer contact for Ourground projecttesting. will sample each Representative loads will be axis of the accelerometer used simulation twice for to simulate the GeoPhone, because commercial GeoPhones are too large, heavy, and expens ...
Improve Operating Efficiency and Reduce Installed Cost
Improve Operating Efficiency and Reduce Installed Cost

Aalborg Universitet Ma, Ke; Liserre, Marco ; Blaabjerg, Frede
Aalborg Universitet Ma, Ke; Liserre, Marco ; Blaabjerg, Frede

Tektronix PS280 User Manual
Tektronix PS280 User Manual

... The PS280 or PS283 DC Power Supply features a constant voltage/constant current automatic crossover. This feature permits continuous operation in the transition from constant-voltage mode to constant-current mode as the load changes. The intersection of the constant-current and constant-voltage mode ...
Aalborg Universitet Applied to Parallel UPS Systems
Aalborg Universitet Applied to Parallel UPS Systems

FMCA Article: “Keep your Motorhome`s Electrical System Safe...”
FMCA Article: “Keep your Motorhome`s Electrical System Safe...”

... circuit. It includes protection against miswired pedestals plus low-voltage (less than 104 volts) and high-voltage (more than 132 volts) protection. It also monitors AC frequency and will shut down power to the motorhome should it be out of tolerance. A handy remote display panel features an LED mon ...
Investigation of a Power Factor Correction Fed
Investigation of a Power Factor Correction Fed

< 1 ... 85 86 87 88 89 90 91 92 93 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report