• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
W. Rieutort-Louis, L. Huang, Y. Hu, J. Sanz Robinson, S. Wagner, J. C. Sturm, and N. Verma, "A Complete Fully Thin-film PV Harvesting and Power-management System on Plastic with On-sheet Battery Management and Wireles Power Delivery to Off-sheet Loads", IEEE Photovoltaic Spec. Conf. (PVSC), Paper 68, Tampa, Fl (JUN 2013).
W. Rieutort-Louis, L. Huang, Y. Hu, J. Sanz Robinson, S. Wagner, J. C. Sturm, and N. Verma, "A Complete Fully Thin-film PV Harvesting and Power-management System on Plastic with On-sheet Battery Management and Wireles Power Delivery to Off-sheet Loads", IEEE Photovoltaic Spec. Conf. (PVSC), Paper 68, Tampa, Fl (JUN 2013).

... resistive loads, Vbattery droops due to the voltage drop across the blocking diode required to sustain IPm gt . A critical condition can be identified where, for a given solar module voltage (Vsolar ), Vbattery has drooped to the point that the charging current (IBatt ) drops to zero (at which point ...
AS32300306
AS32300306

... Fig.1 Power quality problems If exceeds few cycles, motors, robots, servo-drives and machine tools cannot provide control. Both the reliability and quality of supply are equally important. For example, a consumer that is connected to the same bus that supplies a large motor load may have to face a s ...
i.MX 6SoloLite Power Consumption Measurement
i.MX 6SoloLite Power Consumption Measurement

... 4. Reducing Power Consumption . . . . . . . . . . . . . . . . . . 9 5. Use Cases Configuration and Usage Guidelines . . . . 10 ...
Basic Characteristics Data
Basic Characteristics Data

CURRENT HARMONICS GENERATED BY LAMPS: A COMPARISON IN Claudio Cicala
CURRENT HARMONICS GENERATED BY LAMPS: A COMPARISON IN Claudio Cicala

... The European Norms concerning Electromagnetic Compatibility (EMC) focus on the quality of power supply systems and equipment. In particular, the norms prescribe the limits for harmonic current emissions for equipment with an input current up to and including 16 A in specified test conditions [1] and ...
DRM-24V480W1PN (October 2016, Rev. 00)
DRM-24V480W1PN (October 2016, Rev. 00)

... To guarantee sufficient convection cooling, please refer to the following instructions to ensure sufficient clearance around the device. Vertical Mounting: 40mm (1.57 inch) above and 20mm (0.79 inch) below the device as well as a lateral distance of 5mm (0.2 inch) to other units. In case the adjacen ...
Ultracapacitor Based Ride Through System for Anand Vivek Ravi Vinod John
Ultracapacitor Based Ride Through System for Anand Vivek Ravi Vinod John

RF3196 QUAD-BAND GSM850/GSM900/DCS/PCS POWER AMP MODULE Features
RF3196 QUAD-BAND GSM850/GSM900/DCS/PCS POWER AMP MODULE Features

... In the RF3196, is a VBATT tracking circuit that reduces the level of VRAMP as the battery voltage decreases. The limiter is integrated into the CMOS controller and requires no additional input from the user. In the circuit, a feedback loop is implemented that compares VBATT to VCC and produces a cor ...
- IJSRSET
- IJSRSET

... converter-based D-SSSC which can protect and analysis of different simulation based designs. sensitive loads from all supply-side disturbances V. VOLTAGE SAG AND SWELL CAUSED BY other than outages. It is connected in series with a FAULT IN TRANSMISSION LINE distribution feeder and is also capable of ...
Power Flow Control of a Doubly Fed induction Generator (DFIG)
Power Flow Control of a Doubly Fed induction Generator (DFIG)

Synchronous vs. Aynchronous Buck Regulators - Digi
Synchronous vs. Aynchronous Buck Regulators - Digi

ENERCY AND POWER
ENERCY AND POWER

... and R, as you will leam. Energy is the ability to do work, and power is the rate at which energy is used. Current carries electrical energy through a circuit. As the free electrons pass through the resistanceof the circuit, they give up their energy when they collide with atoms in the resistive mate ...
Using a Supercapacitor to Power Wireless Nodes from a 3V Button
Using a Supercapacitor to Power Wireless Nodes from a 3V Button

... • They can be charged at low currents from a low power source • Have low enough ESR to deliver the load power required, even for GSM transmission (~8W), • And high enough C to deliver that power for the duration needed: sufficient energy storage • A supercapacitor looks like a low power load to the ...
Voltage Stability Analysis of Radial Distribution Networks with
Voltage Stability Analysis of Radial Distribution Networks with

Power Over Ethernet, PoE
Power Over Ethernet, PoE

... it doesn’t include the extra sensing and intelligence to determine if the Power Device (called the PD) can accept power over the LAN cable. As such it’s important that the user verifies that the PD is suitable. See the POE-EPE-5818af product below for an injector which includes the full 802.3af ...
Power Transducer User`s Guide
Power Transducer User`s Guide

... Power demand controllers—Control devices designed to minimize and level average demand by maintaining it below some preselected level. This is normally accomplished by shedding and restoring discretionary loads. There are many basic principles of operation of power demand controllers. Power factor—T ...
Embedded Solutions Through Targeted Power Conditioning
Embedded Solutions Through Targeted Power Conditioning

... – Reconnection of power when supply and motor back EMF are in phase, or upon decay of back EMF at or below a predetermined level. – REQUIRES POWER CONDITIONER TO KEEP WAVESYNC POWERED DURING MOMENTARY INTERRUPTION (such as DPI). ...
Pentium® 4 - CS Technion
Pentium® 4 - CS Technion

... providing more transistors, but the improvement in power reduction and speed is much lower than in the past Due to power consumption and power density constrains, we are limited in the amount of logic that can be devoted to improve single thread performance We can use the transistors to add more “lo ...
O A RIGINAL RTICLE
O A RIGINAL RTICLE

... voltage waveform and any deviation from these predesigned magnitude and frequency can cause power quality problems and resultantly failure of equipment on the customer side (Dugan et al. 2003). Among the power quality disturbances, voltage sag and harmonic distortion are the most important disturban ...
PDF
PDF

... relatively easy hence fluctuations can be minimized and also there is increase tracing accuracy. The function of a boost converter is to regulate the output voltage from the PV array at different operating conditions. Figure 11 shows the topology of a DC-DC boost converter, as a combination of power ...
Industrial Static Var Compensator (SVC)
Industrial Static Var Compensator (SVC)

Industrial Static Var Compensator (SVC)
Industrial Static Var Compensator (SVC)

... or relocatable. While outdoor equipment is usually built as fixed structures, indoor equipment is often located within a container that is easily relocatable. It is possible to use a modular design of the SVC. This makes transportation, installation and commissioning at the site fast and easy. ...
objective - Technicalsymposium
objective - Technicalsymposium

Application of Voltage- and Current
Application of Voltage- and Current

Method for conditioning a power supply for starting a jet engine
Method for conditioning a power supply for starting a jet engine

... ments of the speci?c implementation. During the start cycle, ...
< 1 ... 81 82 83 84 85 86 87 88 89 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report