• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Radiation dose reduction in computed tomography
Radiation dose reduction in computed tomography

... Quantifying CT radiation dose & associated risk Radiation dose in CT can be quantified in a variety of ways. Scanner radiation output, organ dose and effective dose are several of the more common dose metrics. The scanner radiation output is currently represented by the volume CT dose index (CTDIvol ...
Page 1 - Madeley High School
Page 1 - Madeley High School

... Madeley High School Radiation and the Universe D questions ...
Innova X-ray Dose Efficiency: Objective Evidence
Innova X-ray Dose Efficiency: Objective Evidence

... complications of decreased heart function, and decreased quality of life. Pediatric interventions are an important case of stochastic risk, since the likelihood of cancer expression may increase with lifetime following exposure, and the young are generally considered more sensitive to radiation expo ...
Applied Physics Radiation Oncology
Applied Physics Radiation Oncology

... Treatment planning includes visualization, localization, field selection and placement, and verification. Visualization is the determination of the location and extent of the tumor, particularly with respect to anatomical landmarks. This process uses every reasonable method of examination, including ...
19 2D and 3D Planning in Brachytherapy
19 2D and 3D Planning in Brachytherapy

... valid for the dose calculation and evaluation. A common procedure, at least in the past for gynaecological and other intracavitary applications, was based on two or more X-ray films, which are mainly used for the 3D reconstruction of the used catheters or applicators. For the intracavitary brachyther ...
01 - Use of a dDVH decomposition technique to evaluate
01 - Use of a dDVH decomposition technique to evaluate

... multimodality medical image registration and treatment application to provide superior accuracy and reproducibility. The recent advent of frameless techniques for the registration of medical images and their accuracy assesment foster the use of multimodal information in radiotherapy and radiosurgery ...
Patient Dose in common CT examinations-2003
Patient Dose in common CT examinations-2003

... data from a wide scale survey. Therefore, it is of great interest whether there are dose quantities whose values are easy to obtain, which can correctly reflect the patient dose and allow assessment of the risk associated with the CT examination. The most widely used CT Dose Quantity is the computed ...
ICRP PUBLICATION 121: Radiological Protection in Paediatric
ICRP PUBLICATION 121: Radiological Protection in Paediatric

... purpose. Reducing doses to reduce detriment to the patient is sensible but, for example, reducing computed tomography doses such that the image no longer gives the necessary diagnostic information, or therapeutic doses such that the procedure is not sufficiently efficacious, is contrary to good medical ...
PDF - Thieme Connect
PDF - Thieme Connect

... values or diagnostic reference levels did not exist. For the first time, the International Commission on Radiological Protection (ICRP) recommended the application of dose reference levels in 1996 [3]. A year later, EURATOM (European Atomic Energy Community), which likewise addresses the requirement ...
The Effects of Organ-based Tube Current Modulation on Radiation
The Effects of Organ-based Tube Current Modulation on Radiation

... The purpose of this thesis was to quantify dose and noise performance of organ-dosebased tube current modulation (ODM) through experimental studies with an anthropomorphic phantom and simulations with a voxelized phantom library. Tube current modulation is a dose reduction technique that modulates r ...
A Monte Carlo dose simulation of chest and hip joint tomosynthesis
A Monte Carlo dose simulation of chest and hip joint tomosynthesis

... possible to produce tomosynthesis images at about the same time as a conventional chest exam. This could possibly give a reduction in the amount of CT scans, which could result in lowering both cost and radiation dose (4). The effective dose from a chest tomosynthesis examination in a study at the U ...
A Monte Carlo based three-dimensional dose reconstruction
A Monte Carlo based three-dimensional dose reconstruction

... Our 3-D pretreatment dose verification should allow an independent verification of IMRT delivery by using measured portal images in combination with an independent dose calculation algorithm based on a Monte Carlo dose engine. Such a model would replace the need for performing film or ionization cha ...
Instruments for Radiation Detection and Measurement
Instruments for Radiation Detection and Measurement

... radiopharmaceutical results in poor-quality images due to the high background from the surrounding tissues and the blood, and gives unnecessary radiation dose to the patient ...
Dose and image quality for a cone-beam C-arm
Dose and image quality for a cone-beam C-arm

... various dose levels and tube voltages and an associated measurement method. Unlike conventional CT, the beam length covers the entire phantom, hence, the concept of computed tomography dose index 共CTDI兲 is not the metric of choice, and one can revert to conventional dosimetry methods by directly mea ...
Contents
Contents

... In this thesis the focus will be on another area of use for the EPID, namely that of dosimetric verification of treatment fields. The idea is to calibrate the detector to give pixel values proportional to dose, so that a portal dose image (PDI) is obtained. To calibrate the EPID for dosimetry requir ...
An Introduction to Fluoroscopy Safety
An Introduction to Fluoroscopy Safety

... No observable effects should occur in most patients. 2-5 Gy Range Doses in this range may result in mild transient erythema appearing within 24 hours and fading by 48 hours. There may also be temporary epilation from exposed skin beginning in about 3 weeks with regrowth in 8 to 12 weeks. Recommended ...
Understanding Radiation Units - Radiation Protection of Patients
Understanding Radiation Units - Radiation Protection of Patients

... • Effective dose takes into account the organ specific radio-sensitivity to develop cancer and hereditary effects from radiation ...
SOMATOM Definition AS
SOMATOM Definition AS

... Every CT examination poses individual and specific requirements to achieve the optimum clinical outcome. These vary from institution to institution, from user to user, from patient to patient, The challenge is to find and apply the ideal settings for every individual examination, but at the same tim ...
IMRT verification by three-dimensional dose reconstruction
IMRT verification by three-dimensional dose reconstruction

... amorphous silicon flat-panel13,14 systems. Pretreatment verification of 2-D intensity-modulated beam portals has also been demonstrated for both camera-based15,16 and liquid ionization chamber-based systems.17,18 In vivo dosimetric measurements were demonstrated using a camera-based EPID by Kirby et ...
Diagnostic Reference Levels in Medical Imaging
Diagnostic Reference Levels in Medical Imaging

... In setting diagnostic reference levels, regional, national and local authorized bodies and professional groups should be cognizant of these considerations. Additional Advice on Diagnostic Reference Levels from ICRP Committee 3 Objective of a Diagnostic Reference Level (12) The objective of a diagnos ...
Study on the Computed Tomography Dose Index volume
Study on the Computed Tomography Dose Index volume

... System); consists of 16 detector cells in the Z direction. Each of the detector cells are 1.25 mm and the detector configurations available were 4 x 1.25 mm, 4 x 2.5 mm, 4 x 3.75 mm, 4 x 5.0 mm, 1 x 1.25 mm, and 2 x 0.63 mm. All dose measurement used a pencil beam ion chamber (VICTOREEN CT Probes, M ...
9 Three-Dimensional Treatment Planning and Conformal Therapy
9 Three-Dimensional Treatment Planning and Conformal Therapy

... The CT scan must be performed with the patient in the treatment position, as determined in the preplanning step. The CT topograms should be generated first and reviewed prior to acquiring the planning scan to insure that patient alignment is correct; adjustments are made if needed. Radiopaque marker ...
AP Revision Guide Ch 18
AP Revision Guide Ch 18

... Every atom contains a nucleus which is composed of protons and neutrons. Because neutrons and protons are similar in many respects they are collectively termed nucleons. The nucleon number (also called the mass number) A of an isotope is the number of protons and neutrons in each nucleus of the isot ...
Radiation Dose and Safety: Informatics Standards and Tools
Radiation Dose and Safety: Informatics Standards and Tools

... of absorbed dose is the gray (Gy), equal to 1 joule of energy deposited in 1 kilogram of medium. A common measurement is air kerma (kinetic energy released in a small volume of air), made using an ionization chamber and electrometer to measure the incident energy, usually in mGy units. Other dose va ...
Does the use of additional X-ray beam filtration during cine
Does the use of additional X-ray beam filtration during cine

... to reduce staff dose [23]. Modern X-ray systems can be programmed to employ Xray beam filters in acquisition as well as in fluoroscopy, and this has become common practice, reducing patient dose in cardiac interventions [15, 27] and neurological interventions [25]. However, the literature demonstrat ...
< 1 2 3 4 5 6 7 ... 10 >

Sievert

The sievert (symbol: Sv) is a derived unit of ionizing radiation dose in the International System of Units (SI). It is a measure of the health effect of low levels of ionizing radiation on the human body.Quantities that are measured in sieverts are intended to represent the stochastic health risk, which for radiation dose assessment is defined as the probability of cancer induction and genetic damage.The sievert is used for radiation dose quantities such as equivalent dose, effective dose, and committed dose. It is used both to represent the risk of the effect of external radiation from sources outside the body, and the effect of internal irradiation due to inhaled or ingested radioactive substances.Conventionally the sievert is not used for high dose rates of radiation which produce deterministic effects, which is the severity of acute tissue damage which is certain to happen. These effects are compared to the physical quantity absorbed dose measured by the unit gray (Gy).To enable consideration of stochastic health risk, calculations are performed to convert the physical quantity absorbed dose into equivalent and effective doses, the details of which depend on the radiation type and biological context. For applications in radiation protection and dosimetry assessment the International Commission on Radiological Protection (ICRP) and International Commission on Radiation Units and Measurements (ICRU) have published recommendations and data which are used to calculate these.The sievert is of fundamental importance in dosimetry and radiation protection, and is named after Rolf Maximilian Sievert, a Swedish medical physicist renowned for work on radiation dosage measurement and research into the biological effects of radiation. One sievert carries with it a 5.5% chance of eventually developing cancer.One sievert equals 100 rem. The rem is an older, non-SI unit of measurement.To enable a comprehensive view of the sievert this article deals with the definition of the sievert as an SI unit, summarises the recommendations of the ICRU and ICRP on how the sievert is calculated, includes a guide to the effects of ionizing radiation as measured in sieverts, and gives examples of approximate figures of dose uptake in certain situations.