• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Power Quality Improvement in 3P4W System Using Unified Power
Power Quality Improvement in 3P4W System Using Unified Power

... system, with their third harmonics component almost as large as the fundamental. The increasing use of non-linear loads, accompanied by an increase in associated problems concerns both electrical utilities and utility customer alike. ...
III. DCS Based Power Distribution System
III. DCS Based Power Distribution System

... Electric energy enters the university with 11KV transmission line from the substation which is stepped down to 400 V by using 300KVA transformer. In this system, the three-phase, 4-wires transformer is used for power distribution to all departments in university campus. This transformer is distribut ...
ECOTAP VPD The new compact class for distribution transformers
ECOTAP VPD The new compact class for distribution transformers

... equipment is supplied with a higher voltage than needed, the equipment consumes more energy than needed. Using a voltage regulation distribution transformer with ECOTAP VPD in the industrial distribution grid allows equipment to be supplied with a voltage actively optimized for it. This reduces ener ...
Building a CIM Network Model
Building a CIM Network Model

... VH = Vnominal-high VL = Vnominal-low ...
Transformers, Per Unit Calculations
Transformers, Per Unit Calculations

... Note: Connection introduces a 30 degree phase shift! Common for transmission/distribution step-down since there is a neutral on the low voltage side. Even if a = 1 there is a sqrt(3) step-up ratio ...
Transformer
Transformer

... • The circuit on the primary side of the transformer is electrically isolated from the circuit on the secondary side of the circuit. • Isolation transformers usually have the same secondary voltage as the primary. • They are mainly used to isolate a piece of equipment from the AC mains for safety re ...
Document
Document

... This time each pixel on the picture consists of only ground or only aerial voltages. The ground mode information corresponds to RED while the aerial mode information corresponds to GREEN. In both cases remaining two color channels are 0 for all pixels. ...
Tue., Mar. 22 notes - UA Atmospheric Sciences
Tue., Mar. 22 notes - UA Atmospheric Sciences

... Some of the earliest estimates of return stroke peak currents come from measurements of the residual magnetism in nephelitic basalt (whatever that is) near trees that were struck by lightning (within centimeters of the tree perhaps). The data were published by Pockels in 1897 & 1898 (the publication ...
Here
Here

... 1] discusses protection applications of the in in-line line transformers where a transmission line of power system terminates on a transformer and a single protection zone includes both the line as well as the transformer. A high quality power transformer properly designed and supplied with suitable ...
Advances in Natural and Applied Sciences
Advances in Natural and Applied Sciences

... between two or more coils with the same frequency and same size. Most electric power networks are designed and implemented in three phases. Because the transmission and distribution of electrical energy in the form of three-phase economically more advantageous and has a higher efficiency, Some netwo ...
2012 45 Winter Wiring Matters
2012 45 Winter Wiring Matters

... to the PME earthing terminal are accessible, people may be subjected to a voltage difference appearing between these parts and true Earth. Where PME electrical supplies are used outdoors or to supply external buildings, it may be pertinent for the electrical installations of these areas to form part ...
Power System Harmonics
Power System Harmonics

... ANSI/IEEE C57.110-1986 (IEEE Recommended Practice for Establishing Transformer Capacity When Supplying Nonsinusoidal Load Currents) states that a transformer subject to nonsinusoidal load current having more than 5% total harmonics distortion needs to be derated. However, when current THD is below ...
A Trek 180_Hobart Spec Sheet
A Trek 180_Hobart Spec Sheet

... Removable power/recharging cord with plug Owner’s Manual with parts lists, installation, operation, maintenance and MIG welding guidelines ...
Document
Document

... dishwashers, washing machines etc. The wire has a quite low melting point. As current flows through the wire it heats up. If too large a current flows it melts, thus breaking the circuit Use appropriate fuse size/rating ...
Modular Power Distribution
Modular Power Distribution

... mm 266 kVA Modular Power Distribution Unit design, a tenfold increase in efficiency yields greater density, reduced floor space, and much lower heat impact on today’s power-hungry data center. Use of higher distribution voltage also brings smaller diameter cord-sets, further reducing first costs. ...
Primary Coil or Primary Winding
Primary Coil or Primary Winding

... 1. There are 400 turns of wire in an ironcore coil. If this coil is to be used as the primary of a transformer, how many turns must be wound on the coil to form the secondary winding of the transformer to have a secondary voltage of one volt if the primary voltage is five volts? 2. A 12 volts transf ...
International Electrical Engineering Journal (IEEJ) Vol. 6 (2015) No.2, pp. 1749-1755
International Electrical Engineering Journal (IEEJ) Vol. 6 (2015) No.2, pp. 1749-1755

... http://www.ieejournal.com/ motor drive system which doesn't need power factor correction capacitor. Also, we cannot depend on this capacitor to filter out those harmonics. This is one of the reasons that the research is being done in the area of APF and less pollutant drives. Loads, such as, diode b ...
IOSR Journal of Electrical and Electronics Engineering (IOSRJEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSRJEEE)

... security [2]. A power system consists of components such as generators, lines, transformers, loads, switches and compensators. However, a widely dispersed power sources and loads are the general configuration of modern power systems [3]. Electric power systems can be divided into two sub-systems, na ...
X-Ray Generators
X-Ray Generators

...  Supplies high voltage for x-ray tube  Step-up transformer  primary from autotransformer  secondary to rectifier circuit  mA monitored at center grounded point of secondary ...
Category 3 Parallel Operating
Category 3 Parallel Operating

... (Project side) of the power transformer, but may instead be connected on the secondary (Utility side). VT’s are required on the secondary of the power transformer if a 59N is required for an ungrounded secondary connection. IEEE std 1547 requirements for voltage and frequency must be met at the PCC. ...
Series Compensation on Medium Voltage Radial Systems
Series Compensation on Medium Voltage Radial Systems

... high voltage transmission systems is well known and its purpose is to increase the capacity of transmission lines, improving the stability in transient and steady states as well as the power flow control through electronic devices that allow varying the capacitive reactance according operational req ...
IEEE Memphis Protection-Basics
IEEE Memphis Protection-Basics

... – Security: Don’t trip when you shouldn’t – Dependability: Trip when you should ...
F42012733
F42012733

... at transmission and distribution level has increased considerably in recent years due to the development in the semiconductor device technology. The equipment needs clean power in order to function properly. At the same time, the switching operation of these devices generates current harmonics resul ...
Philosophy of Topology and Components Selection for
Philosophy of Topology and Components Selection for

... because the inductor itself is not cheap. There will be hard switching of rectifier diodes which will increase energy losses and EMI, and, as a result, increase cost. In this case resonant topologies with ZCS are preferable. The next very important point is what power magnetic components we need to ...
2012
2012

... transformers? Explain. b) Two 1-phase transformers with equal turns have impedances of (0.5+j3) ohm and (0.6+j10) ohm with respect to the secondary. If they are operated in parallel, determine how they share a total load of 100kW at p.f 0.8 lagging. 4. a) Write a note on third harmonics in phase vol ...
< 1 ... 39 40 41 42 43 44 45 46 47 ... 79 >

Single-wire earth return



Single wire earth return (SWER) or single wire ground return is a single-wire transmission line which supplies single-phase electrical power from an electrical grid to remote areas at low cost. Its distinguishing feature is that the earth (or sometimes a body of water) is used as the return path for the current, to avoid the need for a second wire (or neutral wire) to act as a return path. Single-wire earth return is principally used for rural electrification, but also finds use for larger isolated loads such as water pumps. It is also used for high-voltage DC over submarine power cables. Electric single-phase railway traction, such as light rail uses a very similar system. It uses resistors to earth to reduce hazards from rail voltages, but the primary return currents are through the rails.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report