• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
1.2kV Class Super Energy Efficient Harmonic Mitigating Transformer
1.2kV Class Super Energy Efficient Harmonic Mitigating Transformer

... Conservation Standards DOE 10 CFR Part 431; (before DOE referred to as TP1) and/or CSA C802.2 as referenced in the Canadian Energy Efficiency Regulations (SOR/94-651). Total transformer losses are reduced by 30% from these levels when measured under a linear load (K1) profile. There is no energy eff ...
Resident Physics Lectures
Resident Physics Lectures

... – length or wire – other devices sharing branch circuit ...
KGA – AC Interference
KGA – AC Interference

... that can occur in brief amount of time (normally in milliseconds, typically .1 second) ...
01 - Transformer
01 - Transformer

...  Step up transformer, it will decrease the current to keep the power into the device equal to the power out of it.  In modern power system, electrical power is generated at voltage of 12kV to 25kV. Transformer will step up the voltage to between 110kV to 1000kV for transmission over long distance ...
Induced AC creates problems for pipelines in utility corridors
Induced AC creates problems for pipelines in utility corridors

... resulting from lightning strikes and phase faults. When a long-term induced AC voltage exists on a pipeline, it can be dangerous and potentially life-threatening for operations personnel to touch the pipeline or appurtenances. In addition, pipe corrosion also can result from AC discharge. To address ...
SECTION 260573 - ELECTRICAL SYSTEMS ANALYSIS
SECTION 260573 - ELECTRICAL SYSTEMS ANALYSIS

... devices, and include all feeders and ground circuits. Prepare coordination curves to determine the required settings of protective devices to ensure selective coordination. The curves shall graphically illustrate on log paper that adequate time separation exists between series devices. The specific ...
Line to Ground Voltage Monitoring on Ungrounded
Line to Ground Voltage Monitoring on Ungrounded

... B. Ground Fault Indicating Circuits for Ungrounded Systems Despite the advantages of grounding through impedance, many installations remain ungrounded. This is primarily because of economic reasons. In these instances, the circuit depicted in Figure 8 has been commonly used. During a phase A to grou ...
If a voltage loaded at auxiliary relay for the operation of trip circuit
If a voltage loaded at auxiliary relay for the operation of trip circuit

... personnel this protection is ensured, in the case of a fault, by either rapid automatic disconnection of the power supply or by limitation of the resulting touch and step voltages to acceptable levels. Ideally, the generating station and substation should be in close proximity to each other. And to ...
Connection to the LV utility distribution network
Connection to the LV utility distribution network

... Low-voltage consumers are, by definition, those consumers whose loads can be satisfactorily supplied from the low-voltage system in their locality. The voltage of the local LV network may be 120/208 V or 240/415 V, i.e. the lower or upper extremes of the most common 3-phase levels in general use, or ...
Transformer Basics
Transformer Basics

... Very fast rise can cause line insulation to fail – “backflashes” - rise in the 500-2000KV per u-second range and 10-20 u-sec tail (cfo of line - positive polarity waves) – Direct strokes to phase wires (cfo due to negative polarity waves) slightly slower rise and longer tail than backflash BIL: Basi ...
PS1: Overcurrent Protection of a Substation Power Transformer
PS1: Overcurrent Protection of a Substation Power Transformer

... Lab.  The overcurrent protection will act as a backup protection.  When the current through the power transformer exceeds the overcurrent relay set point during a certain time, the transformer is disconnected from the power ...
Power Grid Sensitivity Analysis of Geomagnetically
Power Grid Sensitivity Analysis of Geomagnetically

... where G is an n by n symmetric matrix similar in form to the power system bus admittance matrix, except 1) it is a real matrix with just conductance values, 2) the conductance values are determined by the parallel combination of the three individual phase resistances, 3) G is augmented to include th ...
CP Physics Name Magnetism HW #5 Why is electrical energy
CP Physics Name Magnetism HW #5 Why is electrical energy

... 1) Why is electrical energy transmitted at high voltages and low current? ...
the Medium Voltage Controllable Fuse Brochure
the Medium Voltage Controllable Fuse Brochure

... Comparing the installation costs of the MVCF to a conventional MV Circuit Breaker will clarify the huge difference in site-work, logistics of equipment removal and replacement, liability of sub-contractors, overall man-hours and total downtime. The installed cost of the MVCF can be as little as 20% ...
EZ2500 EZe test instruct rev5_EZ2500 EZe test instruct.qxd
EZ2500 EZe test instruct rev5_EZ2500 EZe test instruct.qxd

... If the E-ZeTest EZ2500 does not power-up, or no messages appear on the LCD, this does not necessarily mean the circuit under test is dead. The phase supply may still be live, but the earth and neutral lines could both be open circuit. Always investigate such conditions with suitable care. Warning Al ...
Design Calculation of Voltage Transformer 66kV Line In 230/66
Design Calculation of Voltage Transformer 66kV Line In 230/66

... oltage transformers is a type of instrument transformer. Which is used in conjunction with measuring instruments, protective relays and control circuits. Instrument transformers are designed to transform voltage or current from the high values in the transmission and distribution systems to low valu ...
A Method to Enhance Ground
A Method to Enhance Ground

... line-to-ground (DLG), and three-phase short-circuit (3SC). Among these types of faults, the SLG occurs most often while the 3SC is commonly deemed the most severe one with largest magnitude of fault current, significantly influencing the decision on the equipments and protective relays setting for p ...
X-Ray Generators
X-Ray Generators

... Filament Transformer Changes AC voltage to smaller voltage required by filament (8-12 volts typical) ...
By— Er Rajinder Kumar Govt polytechnic college Amritsar
By— Er Rajinder Kumar Govt polytechnic college Amritsar

... insulator becomes difficult. Because in higher voltage, the thickness of the insulator become more and a quite thick single piece porcelain insulator can not manufactured practically. In this case we use multiple part pin insulator, where a number of properly designed porcelain shells are fixed toge ...
Surge Protective Devices TransTrack Series:
Surge Protective Devices TransTrack Series:

... TransTrack units come standard with Form “C” dry contacts. The relay contacts are rated 110V DC/125V AC with maximum switching power of 30W DC/62.5VA AC. Use butt splices within the panelboard to connect the Form “C” leads to the user’s monitoring circuits. Alternatively, install a junction box betw ...
New algorithms to improve the sensitivity of differential protection of
New algorithms to improve the sensitivity of differential protection of

... The suggested method is based on the tap changer position monitoring which gives a signal to the digital relay. The position of the tap changer can be detected and communicated to the protection by different ways: - detection with binary input signals to the protection relay. The stepping can be dif ...
Pre lab and Lab 4 for elec 3105 Transformer [no Amplifiers]
Pre lab and Lab 4 for elec 3105 Transformer [no Amplifiers]

... should be noted that (5) is an approximation which is only valid if L1  a 2 RL . In other words, for impedance transformation to work it is vital that the magnitude of the reactance associated with the transformer primary winding be much larger than the transformed load resistance. Under this con ...
Accademia della Luce - educazione alle tecniche della luce
Accademia della Luce - educazione alle tecniche della luce

... the introduction of dangerous electrical potentials caused by failures in other equipments connected to the system. With regard to the latter, it is important to remember that an "improper" earthing system, with the consequent creation of extraneous earth, can be generated by the screenings of the s ...
Turn Ratio
Turn Ratio

... Choosing the Correct Turns Ratio Test In order to determine which type of turns ratio test is most appropriate for a particular transformer, a number of issues should be considered. The table below shows each test with a description, the related specifications and a summary of the benefit provided ...
PowerMax B Series 1170TL B450 / 1400TL B540 / 1500TL B578
PowerMax B Series 1170TL B450 / 1400TL B540 / 1500TL B578

... as standard. The following applications are included at no extra cost: INGECON® SUN Manager, INGECON® SUN Monitor and its Smartphone version Web Monitor, available on the App Store. These applications are used for monitoring and recording the inverter’s internal operating variables through the Inter ...
< 1 ... 40 41 42 43 44 45 46 47 48 ... 79 >

Single-wire earth return



Single wire earth return (SWER) or single wire ground return is a single-wire transmission line which supplies single-phase electrical power from an electrical grid to remote areas at low cost. Its distinguishing feature is that the earth (or sometimes a body of water) is used as the return path for the current, to avoid the need for a second wire (or neutral wire) to act as a return path. Single-wire earth return is principally used for rural electrification, but also finds use for larger isolated loads such as water pumps. It is also used for high-voltage DC over submarine power cables. Electric single-phase railway traction, such as light rail uses a very similar system. It uses resistors to earth to reduce hazards from rail voltages, but the primary return currents are through the rails.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report