• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Overcurrent Protection of a Substation Power Transformer
Overcurrent Protection of a Substation Power Transformer

... (Note: These settings have already been done by the Lab technician) ...
DA100J Series - Murata Power Solutions
DA100J Series - Murata Power Solutions

... i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously ...
- PAT tel doo
- PAT tel doo

... In the standard configurations SPD type 2 / class II are used to protect the remote radio heads against surge voltage. SPD type 2 are capable of handling 40 kA (8/20 For lightning protection SPD type 1 + 2 / class I + II with coordinated spark gab technology are optional available. The current disch ...
Camray™ LED Battery Series
Camray™ LED Battery Series

... c. Units for normal lighting: connect the wire input marked “normal lighting” to the AC line. Identify the wires by color as above. Cap the unused wire with a wire connector. d. DC-remote units: connect the wire input "6-12 VDC" to the DC remote wires. The building emergency circuit must provide 6-v ...
Power Applications
Power Applications

... Dry-type transformers are used to minimize fire hazard and other environmental contamination on surroundings and people, like in large office buildings, hospitals, shopping centers and warehouses, sea going vessels, oil and gas production facilities and other sites where a fire has potential for cat ...
CHAPTER-8 SWITCHYARD EQUIPMENT- HV Bus Bars
CHAPTER-8 SWITCHYARD EQUIPMENT- HV Bus Bars

... case of rigid bus type. Similarly the form of structures also plays an important part and the choice is usually between using a few heavy structures or a large number of smaller structures. While finalizing the design, size and single line diagram of structures, safety clearance requirements should ...
IA = Ica - Engineering.com
IA = Ica - Engineering.com

... •For simplicity, assume currents associated with high-side non-faulted leg are unchanged by the fault •Assume curent associated with high side faulted leg increase in magnitude and rotate toward the lagging direction (fault current is limited by primarily inductive impedances) •In changing the vecto ...
ELG4125: Symmetrical Faults
ELG4125: Symmetrical Faults

... period is called the sub-transient current and is denoted by I”. This current is caused by the damper windings of synchronous machines. The time constant of the sub-transient current is denoted by T” and it can be determined from the slope. This current may be 10 times the steady-state fault current ...
File
File

... Electrical Machines LSEGG216A 9080V ...
Ground Connections
Ground Connections

... ARTECHE Capacitive Couplers for medium voltage power lines used for the transmission of PLC-BPL signals are made up of a silicone module that houses the capacitive part and that provides the necessary electrical insulation, and a polyurethane plastic element which houses the tuning ...
Power for Suspended Scaffolds
Power for Suspended Scaffolds

... operation of a hoist at low voltage by creating it. These transformers are also useful in situations such as parking garages, where there may be 277 volt available, which must be lowered to the proper range needed for a scaffold hoist. In this case, a 15% buck booster would lower the voltage to abou ...
When power interruptions happen.
When power interruptions happen.

... Bad order equipment: Equipment that mis-operated or caused an interruption resulting from equipment being damaged or deteriorated. Breaker lockout (lockout): The operation that occurs when a circuit breaker is unable to clear a fault. When a breaker locks out, it typically results in a sustained int ...
Aalborg Universitet
Aalborg Universitet

... LV-sides of the isolated DC-DC converters can be connected together to a common DC-link as shown in Fig. 7. This scheme allows easier balancing of the power flow between the different phases in MV-side. In addition, interleaving the isolated DCDC converters may help to reduce the ripple in the DC-li ...
Dry-Type Cast Resin, Medium Voltage
Dry-Type Cast Resin, Medium Voltage

... tolerances to eliminate burrs and improve performance. Design configuration is to be step-lap, fully mitered construction for optimum energy efficiency and low noise level. Cores are to be carefully assembled and rigidly held secure with structural steel clamps to minimize gaps. Core is to be protec ...
primary side - Portal UniMAP
primary side - Portal UniMAP

... escape the core and pass through only one of the transformer windings are leakage fluxes. These escaped fluxes produce a self inductance in the primary and secondary coils, and the effects of this inductance must be accounted for. ...
ENERGY CONVERSION ONE
ENERGY CONVERSION ONE

... • Almost all major generation & Distribution Systems in the world are three phase ac systems • Three phase transformers play an important role in these systems • Transformer for 3 phase cct.s is either: (a) constructed from 3 single phase transformers, or (b) another approach is to employ a common c ...
415v distribution for green data centers
415v distribution for green data centers

... Copyright © 2012 Mirus International Inc. 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6. All Rights Reserved. ...
Transformer Excitation Current Test
Transformer Excitation Current Test

... – Use the highest whole number test kV that the test set can operate at, up to the maximum voltage ...
Volts, Amps and Ohms – Measuring Electricity
Volts, Amps and Ohms – Measuring Electricity

... Let's say that you have a power plant that can produce 1 million watts of power. One way to transmit that power would be to send 1 million amps at 1 volt. Another way to transmit it would be to send 1 amp at 1 million volts. Sending 1 amp requires only a thin wire, and not much of the power is lost ...
Chapter 11 Balanced Three-Phase Circuits
Chapter 11 Balanced Three-Phase Circuits

... Three-Phase Circuits Measuring Average Power in ThreePhase Circuits ...
Introduction
Introduction

... are used for three phases. The LV terminals are represented with small letters. Generally a, b & c are used for three phases.  The neutral terminal are represented after line terminals. The capital letter N is used to represent the HV side neutral terminal & small letter n is used for representing ...
999501- How To Eliminate Engine Noises-Radio
999501- How To Eliminate Engine Noises-Radio

... (vehicles battery) (-) negative terminal or battery post. Auto makers do this because is effectively reduces the wire run through the electrical system in half. The auto maker generally only has to run (+) positive voltage wires to components while the (-) negative ground wires can simply be screwed ...
Solution
Solution

... VG 13.2k ...
2012S
2012S

... 6. a) What is the purpose of using deep-bar cage rotors? Explain the construction and working of a deep-bar cage motor. b) The power input to a 3 phase, 6-pole, 440V, 50 Hz induction motor is 80 kW. The rotor e.m.f is observed to make 100 complete revolutions per minute. Calculate i) slip ii) rotor ...
Aalborg Universitet Three-Phase Unbalanced Load Flow Tool for Distribution Networks
Aalborg Universitet Three-Phase Unbalanced Load Flow Tool for Distribution Networks

... among the phases, even though power flow is balanced along a distribution line. For this reason, unbalanced threephase load flow solution will require accurate modeling of distribution lines for the steady-state voltage analysis. Additionally, in reality, loads and distributed generators are usually ...
< 1 ... 42 43 44 45 46 47 48 49 50 ... 79 >

Single-wire earth return



Single wire earth return (SWER) or single wire ground return is a single-wire transmission line which supplies single-phase electrical power from an electrical grid to remote areas at low cost. Its distinguishing feature is that the earth (or sometimes a body of water) is used as the return path for the current, to avoid the need for a second wire (or neutral wire) to act as a return path. Single-wire earth return is principally used for rural electrification, but also finds use for larger isolated loads such as water pumps. It is also used for high-voltage DC over submarine power cables. Electric single-phase railway traction, such as light rail uses a very similar system. It uses resistors to earth to reduce hazards from rail voltages, but the primary return currents are through the rails.