• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Understanding Schmitt Triggers
Understanding Schmitt Triggers

... Most CMOS, BiCMOS and TTL devices require fairly fast edges on the high and low transitions on their inputs. If the edges are too slow they can cause excessive current, oscillation and even damage the device. Slow edges are sometimes hard to avoid at power up or when using push button or manual type ...
ADS1201 数据资料 dataSheet 下载
ADS1201 数据资料 dataSheet 下载

... signal at X4 equals the comparator reference voltage, the output of the comparator switches from negative to positive or positive to negative, depending on its original state. When the output value of the comparator switches from a HIGH to LOW or vise versa, the 1-bit DAC responds on the next clock ...
ECE 2660 Module 5 La..
ECE 2660 Module 5 La..

... This lab is a continuation of Part A using the same circuit. We will emulate an impulse input and look at the resulting estimate of the impulse response. Then we will look at the response of the circuit to a rectangular pulse and compare it with the theoretical result when the captured input is conv ...
Protronic 500/550 Versatile controller with powerful PLC
Protronic 500/550 Versatile controller with powerful PLC

... Voltage at one input ± 10 V Voltage between input and ground ± 50 V ...
Lab 16 - ece.unm.edu
Lab 16 - ece.unm.edu

... CD configurations. The amplifier characteristics of the JFET CS and CD circuits can also be compared to the BJT CE and CC circuits respectively. The main advantage JFET amplifiers have over BJT amplifiers is the high input impedance of JFET circuits. This high input impedance is controlled by the bi ...
AD7485 数据手册DataSheet下载
AD7485 数据手册DataSheet下载

... being clocked out on SDO. A falling edge on TFS brings SDO out of three-state and the data starts to get clocked out on the next rising edge of SCO. Serial Mode Input. A logic low on this pin selects Serial Mode 1 and a logic high selects Serial Mode 2. See the Serial Interface section for further d ...
Power Electronics Laboratory-1 Introduction To
Power Electronics Laboratory-1 Introduction To

... 2. Total result plotted on the screen is limited to 6000 points. In this laboratory, all circuit has been designed to run with demo version. However, high resolution result is not possible. If the simulation result being plotted is more than 6000 points, a warning will be displayed. ...
USB-6008/6009 User Guide and Specifications
USB-6008/6009 User Guide and Specifications

... The following section contains important safety information that you must follow when installing and using the USB-6008/6009. Do not operate the USB-6008/6009 in a manner not specified in this document. Misuse of the device can result in a hazard. You can compromise the safety protection built into ...
Exp3-OpAmpFreqRespon.. - MSU Engineering
Exp3-OpAmpFreqRespon.. - MSU Engineering

... first-order systems, the sinusoidal response depends on both the DC gain, K, and the time constant,. Both, K and  are functions of system parameters. The objective of this experiment is to investigate the effect of system parameters on system response to a sinusoidal input. We will experiment with ...
Analog to Digital Conversion - AHEPL
Analog to Digital Conversion - AHEPL

... in a low level after the data from ADC have ...
AD8005
AD8005

... to create an extra delay in the feedback path. This reduces circuit stability, and can cause unwanted ringing and oscillation. A given value of capacitance causes much less ringing when the amplifier is used with a higher noise gain. The capacitive load drive of the AD8005 can be increased by adding ...
BA304G 2-wire 4/20mA 4 digit indicator
BA304G 2-wire 4/20mA 4 digit indicator

... signal. A root extractor and an adjustable sixteen segment lineariser enable the indicator to display flow and variables such as tank level in linear engineering units. For weighing applications a tare function is included. A large 34mm high 4 digit display provides maximum contrast and has a very w ...
BA324G 2-wire 4/20mA 5 digit indicator
BA324G 2-wire 4/20mA 5 digit indicator

... A root extractor and an adjustable sixteen segment lineariser enable the indicator to display flow and variables such as tank level in linear engineering units. For weighing applications a tare function is included. A large 29mm high 5 digit display and 31 segment bargraph provided maximum contrast ...
80K-40 High Voltage Probe
80K-40 High Voltage Probe

... * The input impedance of Autoranging Fluke handheld digital multimeters varies as a function of range. The only range that deviates significantly from 10 MΩ is the 3V (Models 21, 23, 25, 27, 70, 73, 75, 77) or 4V (Models 10, 11, 12, 29, 79, 83, 85, 86, 87, 88) range where the impedance is 11.11 MΩ. ...
Técnicas de Leitura - Etec Trajano Camargo
Técnicas de Leitura - Etec Trajano Camargo

... Interneting connections will be fast enough to download streaming audio and files, swap digital photos, and hold teleconferences. It will also use the existing spectrum space more efficiently and increase the speeds with which basic data can be transmitted over wireless devices. TEXTO 3 Lamps can be ...
417_1.PDF
417_1.PDF

... baseline. The data is then compensated for droop with a digital IIR filter algorithm that cancels the transformer low frequency pole and establishes a new low frequency pole of 1 rad/sec. To cancel the transformer pole, it is necessary to calculate the droop time constant. This is accomplished by pr ...
16 Channel High Voltage Board
16 Channel High Voltage Board

... voltage scale to 200mVDC with the time base at 50us/division. 3. Turn on the cursor data function dt and the dV on the oscilloscope. 4. Make sure the piezo material is not connected to the high voltage connector assembly. Turn on the high voltage power supply from the power strip. Adjust the voltage ...
Document
Document

... During the laboratory practicals, students will be paired off with a partner with whom they perform the experiment and collect the data. In order to make optimal use of your time in the laboratory, please read the manual and familiarise yourself with the experiment before the laboratory practical. T ...
Lecture 14 - The A to D converter
Lecture 14 - The A to D converter

... only needs to write to ADCTL for the CPU to read results from the register. There are 8 A/D channels but only 4 results from one of the two groups of 4 can be stored at any one time.  Could ...
DEI1166 OCTAL GND/OPEN INPUT, PARALLEL OUTPUT
DEI1166 OCTAL GND/OPEN INPUT, PARALLEL OUTPUT

... Figure 5 depicts the resistance value that when applied between the input and ground, causes the comparator to switch. Lower effective R_Din values can be achieved by adding an external diode isolated pull-up resistor to Vdd (or higher) supply. ...
Operational Amplifiers - Georgia Institute of Technology
Operational Amplifiers - Georgia Institute of Technology

... • These characteristics can be summarized with two ‘golden rules’: 1 - The output attempts to do whatever is necessary to make the voltage difference between the inputs equal to zero (when used in a closed-loop design). 2 - The inputs draw no current. ...
PCI 16-Bit, 1 MHz Multifunction Boards
PCI 16-Bit, 1 MHz Multifunction Boards

... to an analog input sequence. The maximum update rate in this mode is non-­ deterministic and entirely dependent on the PC ­processor speed, the operating ­system, and ­programming environment. In the synchronous output modes, the outputs can be updated directly from memory in the PC, or as the direc ...
DC to 2.0 GHz Multiplier ADL5391
DC to 2.0 GHz Multiplier ADL5391

... general mathematical function that has been field proven to provide an exceptional degree of versatility in function synthesis. VW = α × (VX × VY)/ 1 V + VZ The most significant advance in the ADL5391 is the use of a new multiplier core architecture, which differs markedly from the conventional form ...
DMS-40PC Series - Murata Power Solutions
DMS-40PC Series - Murata Power Solutions

... to ensure technical accuracy, and all of the following circuits have been prototyped and tested to ensure functionality. Please keep in mind, however, that real-world applications are seldom as straightforward as the approaches presented here. All inputs applied to DMS-40PC meters must be steady, dc ...
MAX5166 32-Channel Sample/Hold Amplifier with Four Multiplexed Inputs General Description
MAX5166 32-Channel Sample/Hold Amplifier with Four Multiplexed Inputs General Description

... inputs and independent TTL/CMOS-compatible hold enables for each octal set. Additional 3-bit TTL/CMOScompatible address logic selects the 1-to-8 multiplexer channel. The MAX5166 is available with an output impedance of 50Ω, 500Ω, or 1kΩ, allowing output filtering. The MAX5166 operates with +10V and ...
< 1 ... 46 47 48 49 50 51 52 53 54 ... 97 >

Oscilloscope



An oscilloscope, previously called an oscillograph, and informally known as a scope, CRO (for cathode-ray oscilloscope), or DSO (for the more modern digital storage oscilloscope), is a type of electronic test instrument that allows observation of constantly varying signal voltages, usually as a two-dimensional plot of one or more signals as a function of time. Other signals (such as sound or vibration) can be converted to voltages and displayed.Oscilloscopes are used to observe the change of an electrical signal over time, such that voltage and time describe a shape which is continuously graphed against a calibrated scale. The observed waveform can be analyzed for such properties as amplitude, frequency, rise time, time interval, distortion and others. Modern digital instruments may calculate and display these properties directly. Originally, calculation of these values required manually measuring the waveform against the scales built into the screen of the instrument.The oscilloscope can be adjusted so that repetitive signals can be observed as a continuous shape on the screen. A storage oscilloscope allows single events to be captured by the instrument and displayed for a relatively long time, allowing observation of events too fast to be directly perceptible.Oscilloscopes are used in the sciences, medicine, engineering, and telecommunications industry. General-purpose instruments are used for maintenance of electronic equipment and laboratory work. Special-purpose oscilloscopes may be used for such purposes as analyzing an automotive ignition system or to display the waveform of the heartbeat as an electrocardiogram.Before the advent of digital electronics, oscilloscopes used cathode ray tubes (CRTs) as their display element (hence were commonly referred to as CROs) and linear amplifiers for signal processing. Storage oscilloscopes used special storage CRTs to maintain a steady display of a single brief signal. CROs were later largely superseded by digital storage oscilloscopes (DSOs) with thin panel displays, fast analog-to-digital converters and digital signal processors. DSOs without integrated displays (sometimes known as digitisers) are available at lower cost and use a general-purpose digital computer to process and display waveforms.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report