... Power: 230 Vac 50/60 Hz, 24 Vac or 24 Vdc. Fusing: The controller has no replaceable fuses; protection is provided by means of a self-resetting thermally protected transformer. The 24 V ac or dc version has a solid state multifuse. Indicators: LED indicators for receive and transmit network current ...
... Power: 230 Vac 50/60 Hz, 24 Vac or 24 Vdc. Fusing: The controller has no replaceable fuses; protection is provided by means of a self-resetting thermally protected transformer. The 24 V ac or dc version has a solid state multifuse. Indicators: LED indicators for receive and transmit network current ...
BA324D - FAST Automation srl
... provided which may be used to link the return 4/20mA conductor and the cable screen. Calibration and programming of the instrument is performed via four push-buttons protected from damage and tampering behind a sealed cover. For applications requiring frequent adjustment, the indicator can be suppli ...
... provided which may be used to link the return 4/20mA conductor and the cable screen. Calibration and programming of the instrument is performed via four push-buttons protected from damage and tampering behind a sealed cover. For applications requiring frequent adjustment, the indicator can be suppli ...
UM-45MV 50mV DC Full Scale 4 1/2 DIGIT with 0.56” LEDs
... The UM-45MV is an economical, high resolution DC voltage measuring meter with three header selectable full scale ranges of 50mV, 100mV and 200mV. A five position Span Adjust header facilitates scaling in engineering units. The meter is particularly suited for measuring DC current using 50mV standard ...
... The UM-45MV is an economical, high resolution DC voltage measuring meter with three header selectable full scale ranges of 50mV, 100mV and 200mV. A five position Span Adjust header facilitates scaling in engineering units. The meter is particularly suited for measuring DC current using 50mV standard ...
UM-45MV - Texmate, Inc
... The UM-45MV is an economical, high resolution DC voltage measuring meter with three header selectable full scale ranges of 50mV, 100mV and 200mV. A five position Span Adjust header facilitates scaling in engineering units. The meter is particularly suited for measuring DC current using 50mV standard ...
... The UM-45MV is an economical, high resolution DC voltage measuring meter with three header selectable full scale ranges of 50mV, 100mV and 200mV. A five position Span Adjust header facilitates scaling in engineering units. The meter is particularly suited for measuring DC current using 50mV standard ...
(a) Single-Ended AC Voltage Gain
... The equations (1-14) and (1-15) provide the relationships that can be used to measure Ad and Ac in op-amp circuits. 1. To measure Ad: Set Vi1 = -Vi2 = Vs = 0.5 V, we obtain Vd = 1 V, Vc = 0 V and Vo = Ad Thus, setting the input voltages Vi1 = -Vi2 = 0.5 V results in an output voltage numerically equ ...
... The equations (1-14) and (1-15) provide the relationships that can be used to measure Ad and Ac in op-amp circuits. 1. To measure Ad: Set Vi1 = -Vi2 = Vs = 0.5 V, we obtain Vd = 1 V, Vc = 0 V and Vo = Ad Thus, setting the input voltages Vi1 = -Vi2 = 0.5 V results in an output voltage numerically equ ...
MAX11108 Tiny, 2.1mm x 1.6mm, 3Msps, Low-Power, Serial 12-Bit ADC EVALUATION KIT AVAILABLE
... The MAX11108 is a tiny (2.1mm x 1.6mm), 12-bit, compact, high-speed, low-power, successive approximation analog-to-digital converter (ADC). This high-performance ADC includes a high-dynamic range sample-and-hold and a high-speed serial interface. This ADC accepts a full-scale input from 0V to the ...
... The MAX11108 is a tiny (2.1mm x 1.6mm), 12-bit, compact, high-speed, low-power, successive approximation analog-to-digital converter (ADC). This high-performance ADC includes a high-dynamic range sample-and-hold and a high-speed serial interface. This ADC accepts a full-scale input from 0V to the ...
OR100E/OR300E Handy Oscillographic Recorder (standard model) (harmonic analysis model)
... ● The auto-dialing function can be used to automatically transfer captured data to your fax for high-quality output (as a graphical image). This reduces the need for periodic visits to the measurement site and allows you to respond quicker if a problem is detected. ● If you call your recorder over a ...
... ● The auto-dialing function can be used to automatically transfer captured data to your fax for high-quality output (as a graphical image). This reduces the need for periodic visits to the measurement site and allows you to respond quicker if a problem is detected. ● If you call your recorder over a ...
5.2.2 Digital to Analogue Converters Word Document | GCE
... 1 input signals, by having a voltage gain that reflects this place value. In other words, if the input receiving the least significant bit (lsb) has a voltage gain of G, then the input connected to the next bit must have a gain of 2G, the next input a gain of 4G, and so on. In DAC circuits based on ...
... 1 input signals, by having a voltage gain that reflects this place value. In other words, if the input receiving the least significant bit (lsb) has a voltage gain of G, then the input connected to the next bit must have a gain of 2G, the next input a gain of 4G, and so on. In DAC circuits based on ...
P5.6.2.1 - LD Didactic
... transit time can be determined on the oscilloscope in absolute terms. The light velocity is then calculated as the quotient of the distance and the transit time. ...
... transit time can be determined on the oscilloscope in absolute terms. The light velocity is then calculated as the quotient of the distance and the transit time. ...
CIRCUIT DESCRIPTION - Vintage Radio Info
... through capacitor C39 and the SCA filter, to audio amplifier transistor Q8. The SCA filter, which consists of coil L6 and capacitors C4O a n d C41, removes the 67 kc SCA signal. These signals are not used for stereo reception. The complete stereo multiplex signal consists of the (L+R) main channel, ...
... through capacitor C39 and the SCA filter, to audio amplifier transistor Q8. The SCA filter, which consists of coil L6 and capacitors C4O a n d C41, removes the 67 kc SCA signal. These signals are not used for stereo reception. The complete stereo multiplex signal consists of the (L+R) main channel, ...
$doc.title
... Most power system designers are aware that the impedance of their power input source should be small compared to the input impedance of their switch-‐mode DC-‐DC converter to ensure its stable operation. ...
... Most power system designers are aware that the impedance of their power input source should be small compared to the input impedance of their switch-‐mode DC-‐DC converter to ensure its stable operation. ...
CircuitI_exp101411499585
... For phasor analysis or single frequency analysis we enter 1 in the Total Pts and the same frequency in Start Freq and End Freq as shown in Fig. 1.2 After the circuit is drawn, the specifications for the AC Sweep analysis are given, and the circuit is saved, we are ready to simulate it. 3. Simulate t ...
... For phasor analysis or single frequency analysis we enter 1 in the Total Pts and the same frequency in Start Freq and End Freq as shown in Fig. 1.2 After the circuit is drawn, the specifications for the AC Sweep analysis are given, and the circuit is saved, we are ready to simulate it. 3. Simulate t ...
Zetex - ZXFV4583 Sync separator with variable filter datasheet
... The vertical sync output VSYNC is derived from the Field pulse group. Where there are short equalization pulses in the standard systems, these short pulses are ignored. Essentially, a pulse width discriminator circuit senses the first of the Field pulses, as they are wider than those of the rest of ...
... The vertical sync output VSYNC is derived from the Field pulse group. Where there are short equalization pulses in the standard systems, these short pulses are ignored. Essentially, a pulse width discriminator circuit senses the first of the Field pulses, as they are wider than those of the rest of ...
N2893A 100 MHz Current Probe
... The N2893A is a wide-band, DC to 100 MHz, active current probe. The probe features low noise and low circuit insertion loss. It also features the AutoProbe interface which makes current measurements as simple as those made with active voltage probes. The N2893A has two operating regions that provide ...
... The N2893A is a wide-band, DC to 100 MHz, active current probe. The probe features low noise and low circuit insertion loss. It also features the AutoProbe interface which makes current measurements as simple as those made with active voltage probes. The N2893A has two operating regions that provide ...
Sinusoidal oscillator
... What should be the value of the forward transmission (basic amplifier’s gain) a in order to ensure the oscillation? What happens with the output signal vO if a decreases under this value? What if a increases over this value? As you can see from the scheme in Fig. 1, the circuit doesn’t have an i ...
... What should be the value of the forward transmission (basic amplifier’s gain) a in order to ensure the oscillation? What happens with the output signal vO if a decreases under this value? What if a increases over this value? As you can see from the scheme in Fig. 1, the circuit doesn’t have an i ...
Electromagnetic Interference and Digital Circuits: An
... pulse wave with high frequency sinsoid wave, into the clock network of the testing circuit to observe the output effects. The complete experimental setup is shown in Fig. 3. The 20 dB coupler is used to measure the power that is delivered into the circuit and the reflected power. A bias T is usually ...
... pulse wave with high frequency sinsoid wave, into the clock network of the testing circuit to observe the output effects. The complete experimental setup is shown in Fig. 3. The 20 dB coupler is used to measure the power that is delivered into the circuit and the reflected power. A bias T is usually ...
Introduction - Simple Media Networks, Inc
... buffers. Pin headers J2 and J4 are used to select between differential and single-ended input. This is accomplished by either shorting the barrel of the RCA connector to the – input of the buffer for differential operation, or shorting the barrel of the RCA connector and – input of the buffer to gro ...
... buffers. Pin headers J2 and J4 are used to select between differential and single-ended input. This is accomplished by either shorting the barrel of the RCA connector to the – input of the buffer for differential operation, or shorting the barrel of the RCA connector and – input of the buffer to gro ...
ADS822 数据资料 dataSheet 下载
... See Figure 2 for the typical circuit for an AC-coupled analog input configuration of the ADS822 and ADS825 while all components are powered from a single +5V supply. ...
... See Figure 2 for the typical circuit for an AC-coupled analog input configuration of the ADS822 and ADS825 while all components are powered from a single +5V supply. ...
DLSeries Accessories
... •For measuring signals floating from ground in a high-speed digital circuit •Input capacity : 2.5 pF •For high speed differential measurement such as LVDS •System measurements up to 1.5 GHz BW with DL9200 ...
... •For measuring signals floating from ground in a high-speed digital circuit •Input capacity : 2.5 pF •For high speed differential measurement such as LVDS •System measurements up to 1.5 GHz BW with DL9200 ...
A High Swing Range, High Bandwidth CMOS PGA and ADC for IF
... value(RV) is selected using the select signal s<63:0>. Also at the type II, the variable resistor value(RV) is selected using the select signal s<63:0>. The variable resistor value(RV) is consisted of the resistance of the transistor and resistor. The weak point of the conventional PGA is that when ...
... value(RV) is selected using the select signal s<63:0>. Also at the type II, the variable resistor value(RV) is selected using the select signal s<63:0>. The variable resistor value(RV) is consisted of the resistance of the transistor and resistor. The weak point of the conventional PGA is that when ...
FEATURES PIN CONFIGURATION
... See Typical Performance Curves for operation between 85°C and 125°C ...
... See Typical Performance Curves for operation between 85°C and 125°C ...
Lab4_ES3_2007 - Electrical and Computer Engineering
... (2) The 100μF capacitor between the output of the amplifier and the speaker also looks like an open circuit as f0. This effectively disconnects the speaker from the amplifier for low frequency signals. Both of these phenomena are known as “high-pass filters.” That is, the part of the circuit consis ...
... (2) The 100μF capacitor between the output of the amplifier and the speaker also looks like an open circuit as f0. This effectively disconnects the speaker from the amplifier for low frequency signals. Both of these phenomena are known as “high-pass filters.” That is, the part of the circuit consis ...
syed azeem ahmed
... sampling rates a little in the previous section and we'll elaborate more on it later, but for now, let's concentrate on quantization of the signal level. As we've already seen, a PCM-based digital audio system has a finite number of levels that can be used to specifiy the signal level for a particul ...
... sampling rates a little in the previous section and we'll elaborate more on it later, but for now, let's concentrate on quantization of the signal level. As we've already seen, a PCM-based digital audio system has a finite number of levels that can be used to specifiy the signal level for a particul ...
Analog Shield Reference Manual
... Unlike the native analog input of the Arduino, the Analog Shield provides a 16 bit ADC, (as opposed to 10bits provided by the Arduino UNO and the ChipKIT UNO32) offering greater precision (about 25dB) than the Arduino or chipKIT. Additionally, the ADC works as a bipolar input, meaning that sense sig ...
... Unlike the native analog input of the Arduino, the Analog Shield provides a 16 bit ADC, (as opposed to 10bits provided by the Arduino UNO and the ChipKIT UNO32) offering greater precision (about 25dB) than the Arduino or chipKIT. Additionally, the ADC works as a bipolar input, meaning that sense sig ...
Oscilloscope
An oscilloscope, previously called an oscillograph, and informally known as a scope, CRO (for cathode-ray oscilloscope), or DSO (for the more modern digital storage oscilloscope), is a type of electronic test instrument that allows observation of constantly varying signal voltages, usually as a two-dimensional plot of one or more signals as a function of time. Other signals (such as sound or vibration) can be converted to voltages and displayed.Oscilloscopes are used to observe the change of an electrical signal over time, such that voltage and time describe a shape which is continuously graphed against a calibrated scale. The observed waveform can be analyzed for such properties as amplitude, frequency, rise time, time interval, distortion and others. Modern digital instruments may calculate and display these properties directly. Originally, calculation of these values required manually measuring the waveform against the scales built into the screen of the instrument.The oscilloscope can be adjusted so that repetitive signals can be observed as a continuous shape on the screen. A storage oscilloscope allows single events to be captured by the instrument and displayed for a relatively long time, allowing observation of events too fast to be directly perceptible.Oscilloscopes are used in the sciences, medicine, engineering, and telecommunications industry. General-purpose instruments are used for maintenance of electronic equipment and laboratory work. Special-purpose oscilloscopes may be used for such purposes as analyzing an automotive ignition system or to display the waveform of the heartbeat as an electrocardiogram.Before the advent of digital electronics, oscilloscopes used cathode ray tubes (CRTs) as their display element (hence were commonly referred to as CROs) and linear amplifiers for signal processing. Storage oscilloscopes used special storage CRTs to maintain a steady display of a single brief signal. CROs were later largely superseded by digital storage oscilloscopes (DSOs) with thin panel displays, fast analog-to-digital converters and digital signal processors. DSOs without integrated displays (sometimes known as digitisers) are available at lower cost and use a general-purpose digital computer to process and display waveforms.