• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
MT-055 TUTORIAL  Chopper Stabilized (Auto-Zero) Precision Op Amps
MT-055 TUTORIAL Chopper Stabilized (Auto-Zero) Precision Op Amps

... (switches in "S" position), the nulling amplifier, A2, monitors the input offset voltage of A1 and drives its output to zero by applying a suitable correcting voltage at A1's null pin. Note, however, that A2 also has an input offset voltage, so it must correct its own error before attempting to null ...
Bioelectric Amplifiers
Bioelectric Amplifiers

... clearly dc or change very slowly (0.05 Hz) Exceptional for EX.: ECG signal should be AC coupled despite of the component as low as 0.05 Hz to overcome electrode offset potential from electrode-skin connection The high-frequency response is the frequency at which the gain drops 3dB below its midfre ...
HYPERLYNX A PWB DESIGN TOOL
HYPERLYNX A PWB DESIGN TOOL

... A signal trace should ideally run over an unbroken plane layer so that the current return is in the image of the trace A slot in the plane under a signal trace will result in significant radiation from the trace ...
EECS 210 Lab Manual
EECS 210 Lab Manual

... The sine and square waves can be set from 0.1 mHz to 15 MHz. The triangular and sawtooth waves can be set from 0.1 mHz to 100 KHz. 3. To Set the Amplitude: ...
Print Layout 1 - Smart Tweezers
Print Layout 1 - Smart Tweezers

... For automatic measurement use AUTO setting (default). Use fixed test frequency for specific measurements, such as very small or very large capacitance (less than 50pf or more than 100uF) or inductance. ...
AC Servo Driver - tamagawa seiki co.,ltd.
AC Servo Driver - tamagawa seiki co.,ltd.

... P2H:Correspondence from 17bit to 23bit of resolvers,incremental,abso, ...
AN023: Low Cost Digital Panel Meter Designs
AN023: Low Cost Digital Panel Meter Designs

... The limitations of the on-chip reference should also be recognized, however. With the ICL7107, the internal heating which results from the LED drivers can cause some degradation in performance. Due to its high thermal resistance, plastic parts are poorer in this respect than ceramic. The user is cau ...
ES636 True RMS-to-DC Converters  Features
ES636 True RMS-to-DC Converters Features

... is chosen, the additional error at 30Hz will be 1%. If the DC error can be rejected, a capacitor should be connected in series with the input, as would typically be the case in single-supply operation. The input and output signal ranges are a function of the supply voltages. Refer to the electrical ...
AD706
AD706

... in five performance grades. The AD706J is rated over the commercial temperature range of 0°C to +70°C. The AD706A is rated for the extended industrial temperature range of –40°C to +85°C. The AD706 is offered in two varieties of an 8-lead package: plastic mini-DIP and surface-mount (SOIC). ...
Tektronix Curve Tracers - University of Saskatchewan
Tektronix Curve Tracers - University of Saskatchewan

... vertical axis. The vertical position control is located underneath this knob. In the top right corner is the horizontal volts/div knob. Again, as with the vertical knob, it can display the collector or base volts along the horizontal axis. The horizontal position control is located underneath this k ...
Section B6: Rectification Using Semiconductor Diodes
Section B6: Rectification Using Semiconductor Diodes

... Practically, we live in an ac world. However, many times a dc signal is required and we have to have a way to convert between ac and dc. This requires restricting the original ac signal that may alternate between positive and negative values to one that has values only on one side of the zero refere ...
HMC346AMS8GE (v01.0117) - Preliminary Data
HMC346AMS8GE (v01.0117) - Preliminary Data

... operating from DC - 8 GHz. It features an on-chip reference attenuator for use with an external op-amp to provide simple single voltage attenuation control, 0 to -5V. The device is ideal in designs where an analog DC control signal must control RF signal levels over a 30 dB amplitude range. Applicat ...
DC1783A - Linear Technology
DC1783A - Linear Technology

... capacitor (C17). The circuit in Figure 3 can be implemented on the DC1783A by putting JP1 and JP5 in the AC position, moving R32 and R36 to the R31 and R38 positions and adding a 1k resistor at the R9 location. At this point it will be necessary to drive both AIN+ and AIN–. One of these RC pairs can ...
HV Capacitor Location Study, doc
HV Capacitor Location Study, doc

... Pulse generator (1 V peak, 2 ns rise time, 3 mu-sec, yellow trace, 2 V scale) -> HV cable (wire 16, open end) Wire #6 plugged into LST tube #13, channel B Observe pickup on phi strip above this wire (blue trace, 5 mV scale) The picture shows the worst case scenario. Every other combination was way b ...
Fundamentals of Signature Analysis
Fundamentals of Signature Analysis

... basic components responds differently to the instrument’s test signal. Recognizing these four basic unique signatures on the instrument display is one of the keys to successful ASA troubleshooting. When components are connected together to form a circuit, the signature at each circuit node is a comp ...
hand-held digital synchro meter high accuracy 5 digit dsm-5
hand-held digital synchro meter high accuracy 5 digit dsm-5

... The heart of the DSM-5 is a 16 bit synchro to digital converter. The reference input (R1-R2) and synchro stator (S1-S2-S3) signals are combined creating a synthesized reference signal that is in-phase with the stator signals. The synchro stator signals are converted to sine and cosine voltages via a ...
LIOB‑100/101/102/103
LIOB‑100/101/102/103

... temperature sensors (e.g. Pt1000, NTC10K, NTC1K8, Ni1000) fixed internal translation tables are provided. For all other temperature sensors, translation tables can be defined in the configuration tool and used on the device. The average sampling period p of analog inputs depends on the number of act ...
Hybrid Recorder, Pen Type SR
Hybrid Recorder, Pen Type SR

... MUL (arithmetic 1), DIV (arithmetic 2), High-Peak (max value), Low-Peak (min value), Average, Power (exponent), Formula, BrokenLine (broken line approximation) 100 to 240 Vac, 50/60 Hz 40 VA max . Set contents maintained by nonvolatile RAM. Clock data maintained by lithium battery. (Data saved for m ...
AD706 Dual Picoampere Input Current Bipolar Op Amp
AD706 Dual Picoampere Input Current Bipolar Op Amp

... in five performance grades. The AD706J is rated over the commercial temperature range of 0°C to +70°C. The AD706A is rated for the extended industrial temperature range of –40°C to +85°C. The AD706 is offered in two varieties of an 8-lead package: plastic mini-DIP and surface-mount (SOIC). ...
The Need for High Resolution, Wide Dynamic Range Current
The Need for High Resolution, Wide Dynamic Range Current

... error at the displayed volts/division). Given the measurements with the "standard" probe in the example above (operating current 200% too high and sleep current over 10X too high compared to the micro’s specs), an engineer could spend several very frustrating weeks trying to solve a power consumpti ...
Input Bias Current Compensation
Input Bias Current Compensation

... This current flows through the source resistance (Rs) of the signal source driving the amplifier input. If that signal source has a high-impedance, the small current from the amplifier’s input causes an additional voltage drop (VIoff = Ib x Rs). That small voltage drop also appears at the amplifier’ ...
VOLTAGE LEVEL TRANSLATION (SL) - Family
VOLTAGE LEVEL TRANSLATION (SL) - Family

... The 3-dB point of the clamp is ≈600 MHz. However, this measurement is an analog type of measurement. For digital applications the signal should not degrade up to the fifth harmonic of the digital signal. As a rule of thumb, the frequency bandwidth should be at least five times the maximum digital cl ...
Delta Modulation For Voice Transmission
Delta Modulation For Voice Transmission

... 4) Digital inputs and outputs are similar to and compatible with standard CMOS logic circuits using the same supply voltage. The illustrated 10K pullup resistors are necessary only with mechanical switches, and are not necessary when driving these pins with CMOS. Unused digital inputs should be tied ...
AD676 - Analog Devices
AD676 - Analog Devices

... array eliminates variation in the linearity of the device due to temperature-induced mismatches of resistor values. Since a capacitor array is used to perform the data conversions, the sample/hold function is included without the need for additional external circuitry. ...
Model 855 Specification 1.4 - Berkeley Nucleonics Corporation
Model 855 Specification 1.4 - Berkeley Nucleonics Corporation

< 1 ... 49 50 51 52 53 54 55 56 57 ... 97 >

Oscilloscope



An oscilloscope, previously called an oscillograph, and informally known as a scope, CRO (for cathode-ray oscilloscope), or DSO (for the more modern digital storage oscilloscope), is a type of electronic test instrument that allows observation of constantly varying signal voltages, usually as a two-dimensional plot of one or more signals as a function of time. Other signals (such as sound or vibration) can be converted to voltages and displayed.Oscilloscopes are used to observe the change of an electrical signal over time, such that voltage and time describe a shape which is continuously graphed against a calibrated scale. The observed waveform can be analyzed for such properties as amplitude, frequency, rise time, time interval, distortion and others. Modern digital instruments may calculate and display these properties directly. Originally, calculation of these values required manually measuring the waveform against the scales built into the screen of the instrument.The oscilloscope can be adjusted so that repetitive signals can be observed as a continuous shape on the screen. A storage oscilloscope allows single events to be captured by the instrument and displayed for a relatively long time, allowing observation of events too fast to be directly perceptible.Oscilloscopes are used in the sciences, medicine, engineering, and telecommunications industry. General-purpose instruments are used for maintenance of electronic equipment and laboratory work. Special-purpose oscilloscopes may be used for such purposes as analyzing an automotive ignition system or to display the waveform of the heartbeat as an electrocardiogram.Before the advent of digital electronics, oscilloscopes used cathode ray tubes (CRTs) as their display element (hence were commonly referred to as CROs) and linear amplifiers for signal processing. Storage oscilloscopes used special storage CRTs to maintain a steady display of a single brief signal. CROs were later largely superseded by digital storage oscilloscopes (DSOs) with thin panel displays, fast analog-to-digital converters and digital signal processors. DSOs without integrated displays (sometimes known as digitisers) are available at lower cost and use a general-purpose digital computer to process and display waveforms.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report