• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Digital holography of total internal reflection
Digital holography of total internal reflection

Modeling, Simulation and Application of the Probe Beam Deflection
Modeling, Simulation and Application of the Probe Beam Deflection

Full text - Ward Ober Lab
Full text - Ward Ober Lab

Here is the Original File
Here is the Original File

INTRODUCTION          ...
INTRODUCTION ...

THERMAL ANALYSIS
THERMAL ANALYSIS

TR555 - Princeton Instruments
TR555 - Princeton Instruments

Chapter 11 * Chemical Reactions
Chapter 11 * Chemical Reactions

Collision-induced Raman scattering by rare-gas atoms: The
Collision-induced Raman scattering by rare-gas atoms: The

2012 HSC Senior Science Sample Answers
2012 HSC Senior Science Sample Answers

This space should be left blank, except for the name of the first author.
This space should be left blank, except for the name of the first author.

... ranges are illustrated in Fig.2b. The front optics optically delivers the ECE radiation onto a pair of independent heterodyne detector arrays. The lenses in the front optics, made of high density polyethylene (HDPE), provide flexible zooming and focusing like a camera lens [7]. Note that the radial ...
What can we learn from hydrodynamic analysis at RHIC?
What can we learn from hydrodynamic analysis at RHIC?

... Ideal, Chem. Eq. Hadronic Fluid After the famous Landau’s paper (1953), ideal and chemical equilibrium hadronic hydrodynamics has been exploited for a long time. However, the model may not be used when chemical freezeout happens earlier than thermal freezeout since it accidentally reproduces ...
Measurements - Effingham County Schools
Measurements - Effingham County Schools

Confocal microscopy with a volume holographic filter
Confocal microscopy with a volume holographic filter

Mechanical monitoring of the degradation of hydrogels
Mechanical monitoring of the degradation of hydrogels

Fiberoptic Sample Holder (FOSH): Characteristics and Uses APPLICATION NOTE 1056-201
Fiberoptic Sample Holder (FOSH): Characteristics and Uses APPLICATION NOTE 1056-201

of the Physical and Technical Faculty
of the Physical and Technical Faculty

... The course "Laboratory Practicum on Optical Devices" is destined to the study of the optical techniques, devices and its applications, most important effects and laws. The course consists of laboratory works and seminars. The seminars are primarily intended to familiarize with the studied optical ph ...
Image reconstruction in diffuse optical tomography based on
Image reconstruction in diffuse optical tomography based on

... can be modeled in the forward problem, its sensitivity to the measured boundary data is limited to superficial regions and more importantly, due to uniqueness of the inverse problem it cannot be determined using frequency domain data. Image reconstruction through the use of higher ordered models is ...
[pdf]
[pdf]

~ )   Pergamon
~ ) Pergamon

Near-field amplitude and phase recovery using phase
Near-field amplitude and phase recovery using phase

An-Introduction-to-Spectrometric
An-Introduction-to-Spectrometric

Absorption and fluorescence spectra of poly
Absorption and fluorescence spectra of poly

... linearity to OD =3) mated to a Perkin-Elmer 7500 microcomputer. Fluorescence spectra were taken on a Spex Fluorolog 212 spectrofluorimeter with a 450 W ...
Resolution scaling in STED microscopy
Resolution scaling in STED microscopy

supporting material
supporting material

< 1 ... 21 22 23 24 25 26 27 28 29 ... 57 >

Chemical imaging

Chemical imaging (as quantitative – chemical mapping) is the analytical capability to create a visual image of components distribution from simultaneous measurement of spectra and spatial, time information.The main idea - for chemical imaging, the analyst may choose to take as many data spectrum measured at a particular chemical component in spatial location at time; this is useful for chemical identification and quantification. Alternatively, selecting an image plane at a particular data spectrum (PCA - multivariable data of wavelength, spatial location at time) can map the spatial distribution of sample components, provided that their spectral signatures are different at the selected data spectrum.Software for chemical imaging is most specific and distinguished from chemical methods such as chemometrics. Hyperspectral imaging is most often applied to either solid or gel samples, and has applications in chemistry, biology, medicine, pharmacy (see also for example: food science, biotechnology, agriculture and industry. NIR, IR and Raman chemical imaging is also referred to as hyperspectral, spectroscopic, spectral or multispectral imaging (also see microspectroscopy). However, other ultra-sensitive and selective imaging techniques are also in use that involve either UV-visible or fluorescence microspectroscopy. Many imaging techniques can be used to analyze samples of all sizes, from the single molecule to the cellular level in biology and medicine, and to images of planetary systems in astronomy, but different instrumentation is employed for making observations on such widely different systems.Imaging instrumentation has three components: a radiation source to illuminate the sample, a spectrally selective element, and usually a detector array (the camera) to collect the images. When many stacked spectral channels (wavelengths) are collected for different locations of the microspectrometer focus on a line or planar array in the focal plane, the data is called hyperspectral; fewer wavelength data sets are called multispectral. The data format is called a hypercube. The data set may be visualized as a data cube, a three-dimensional block of data spanning two spatial dimensions (x and y), with a series of wavelengths (lambda) making up the third (spectral) axis. The hypercube can be visually and mathematically treated as a series of spectrally resolved images (each image plane corresponding to the image at one wavelength) or a series of spatially resolved spectra. Many materials, both manufactured and naturally occurring, derive their functionality from the spatial distribution of sample components. For example, extended release pharmaceutical formulations can be achieved by using a coating that acts as a barrier layer. The release of active ingredient is controlled by the presence of this barrier, and imperfections in the coating, such as discontinuities, may result in altered performance. In the semi-conductor industry, irregularities or contaminants in silicon wafers or printed micro-circuits can lead to failure of these components. The functionality of biological systems is also dependent upon chemical gradients – a single cell, tissue, and even whole organs function because of the very specific arrangement of components. It has been shown that even small changes in chemical composition and distribution may be an early indicator of disease. Any material that depends on chemical gradients for functionality may be amenable to study by an analytical technique that couples spatial and chemical characterization. To efficiently and effectively design and manufacture such materials, the ‘what’ and the ‘where’ must both be measured. The demand for this type of analysis is increasing as manufactured materials become more complex. Chemical imaging techniques is critical to understanding modern manufactured products and in some cases is a non-destructive technique so that samples are preserved for further testing.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report