Mechanical Properties and Microstructure of Zinc Oxide
... Zinc oxide varistors are strongly nonlinear resistors that have been used to regulate transient voltage surges of unwanted magnitude for high voltage and power-related applications, such as surge arresters in power transmission and distribution for the protection of electronic devices. The ZnO varis ...
... Zinc oxide varistors are strongly nonlinear resistors that have been used to regulate transient voltage surges of unwanted magnitude for high voltage and power-related applications, such as surge arresters in power transmission and distribution for the protection of electronic devices. The ZnO varis ...
Measuring cellular structure at submicrometer scale with light
... thus, the phase shift depends strongly on . Therefore, approach zero rapidly as increases. Thus, the scattering by ...
... thus, the phase shift depends strongly on . Therefore, approach zero rapidly as increases. Thus, the scattering by ...
Effective Charge Transfer Distances in Cyanide
... The proportionality factor on the right-hand side of eq 7 depends only on the field strength F and the angle χ, both experimental parameters, and on the angle ζA between ∆µ b and m b , which can be measured, so this ratio of experimental data provides an independent approach for obtaining |∆µ|. The ...
... The proportionality factor on the right-hand side of eq 7 depends only on the field strength F and the angle χ, both experimental parameters, and on the angle ζA between ∆µ b and m b , which can be measured, so this ratio of experimental data provides an independent approach for obtaining |∆µ|. The ...
Spectral Domain Optical Coherence Tomography
... technologies have not allowed for accurate maps of optic nerve head topography. Even with the ultra-high resolution titanium-sapphire lasers, slower acquisition speeds necessitate realignment of A-scans, which do not allow for evaluation of the true optic nerve head topography.14 With the ultra-high ...
... technologies have not allowed for accurate maps of optic nerve head topography. Even with the ultra-high resolution titanium-sapphire lasers, slower acquisition speeds necessitate realignment of A-scans, which do not allow for evaluation of the true optic nerve head topography.14 With the ultra-high ...
Untitled
... Fourier transform spectroscopy, with its ability to optimize spectral coverage, optical throughput and resolution has found broad and increasing application in astronomy, earth and planetary sciences, laboratory spectroscopy, industry and medicine. FTS covers recent developments in instrument design ...
... Fourier transform spectroscopy, with its ability to optimize spectral coverage, optical throughput and resolution has found broad and increasing application in astronomy, earth and planetary sciences, laboratory spectroscopy, industry and medicine. FTS covers recent developments in instrument design ...
Introduction to Adaptive Optics and Deformable
... Understanding Wavefronts | Adaptive Optical Elements and Systems | Key Parameters| Applications In optical systems misalignment of components, imperfections in elements, or aberrations can internally reduce performance, while heat and atmosphere can Deformable Mirrors externally reduce performance. ...
... Understanding Wavefronts | Adaptive Optical Elements and Systems | Key Parameters| Applications In optical systems misalignment of components, imperfections in elements, or aberrations can internally reduce performance, while heat and atmosphere can Deformable Mirrors externally reduce performance. ...
Measurement and data processing and analysis
... significant figures of the measurement. There are two significant figures, for example, in 62 cm3 and five in 100.00 g. The zeros are significant here as they signify that the uncertainty range is (±) 0.01 g. The number of significant figures may not always be clear. If a time measurement is 1000 s, ...
... significant figures of the measurement. There are two significant figures, for example, in 62 cm3 and five in 100.00 g. The zeros are significant here as they signify that the uncertainty range is (±) 0.01 g. The number of significant figures may not always be clear. If a time measurement is 1000 s, ...
DENTAL RADIOGRAPHIC TECHNIQUES FOR THE HORSE
... The mouth is opened fully with a speculum or bite block. The plate/sensor is placed on the side of the horse’s head, with the center of the plate over the rostral end of the facial crest. The clinical crowns of the mandibular cheek teeth are imaged by directing the central beam 10-30 degrees to the ...
... The mouth is opened fully with a speculum or bite block. The plate/sensor is placed on the side of the horse’s head, with the center of the plate over the rostral end of the facial crest. The clinical crowns of the mandibular cheek teeth are imaged by directing the central beam 10-30 degrees to the ...
Experimental method for reliably establishing the refractive index of
... C. raja, a buprestid beetle, has an iridescent green colour over the whole of its body except for a red stripe on each elytral wing (Fig. 1). It displays the normal iridescence associated with conventional multilayers; its peak reflected colour reduces in wavelength as the angle of incidence increas ...
... C. raja, a buprestid beetle, has an iridescent green colour over the whole of its body except for a red stripe on each elytral wing (Fig. 1). It displays the normal iridescence associated with conventional multilayers; its peak reflected colour reduces in wavelength as the angle of incidence increas ...
The Atomic, Molecular and Optical Science
... then spreads over the entire molecule via separate processes depending on the internuclear separation at the time of ionization. Measuring charge state and kinetic energy distributions of the fragment ions as a function of NIR–X-ray delay allows for a detailed analysis of charge redistribution betwe ...
... then spreads over the entire molecule via separate processes depending on the internuclear separation at the time of ionization. Measuring charge state and kinetic energy distributions of the fragment ions as a function of NIR–X-ray delay allows for a detailed analysis of charge redistribution betwe ...
Get PDF - OSA Publishing
... distribution of RI of a semi-transparent object, in our case a pollen grain, provided by backprojecting OPL values collected with digital holographic microscopy (DHM) on a series of projections of the preparation taken at various incidence angles. The accuracy of the RI determination was better than ...
... distribution of RI of a semi-transparent object, in our case a pollen grain, provided by backprojecting OPL values collected with digital holographic microscopy (DHM) on a series of projections of the preparation taken at various incidence angles. The accuracy of the RI determination was better than ...