
Technical Standard – TS 130
... such that voltage variations are maintained within prescribed limits. The generating system’s reactive power output must be controlled within an agreed range. A generating system would typically be expected to be capable of continuously supplying or absorbing reactive power to achieve a power factor ...
... such that voltage variations are maintained within prescribed limits. The generating system’s reactive power output must be controlled within an agreed range. A generating system would typically be expected to be capable of continuously supplying or absorbing reactive power to achieve a power factor ...
ADS7843 数据资料 dataSheet 下载
... the on-resistance of the Y drivers does make a small difference. Under the situation outlined so far, it would not be possible to achieve a 0V input or a full-scale input regardless of where the pointing device is on the touch screen because some voltage is lost across the internal switches. In addi ...
... the on-resistance of the Y drivers does make a small difference. Under the situation outlined so far, it would not be possible to achieve a 0V input or a full-scale input regardless of where the pointing device is on the touch screen because some voltage is lost across the internal switches. In addi ...
MAX4370 Current-Regulating Hot-Swap Controller with DualSpeed/BiLevel Fault Protection General Description
... During start-up, the slow comparator is disabled and current limiting is provided two different ways: 1) Slow ramping of the current to the load by controlling the external MOSFET gate voltage. 2) Limiting the current to the load by regulating the voltage across the external current-sense resistor. ...
... During start-up, the slow comparator is disabled and current limiting is provided two different ways: 1) Slow ramping of the current to the load by controlling the external MOSFET gate voltage. 2) Limiting the current to the load by regulating the voltage across the external current-sense resistor. ...
GaN for LDMOS Users
... temperature of 200°C. All 12 devices showed maximum degradation <0.25dB after 500 hours. Gate current was negative for all of these devices during the test. For these devices to be used past the 1dB compression point, there are 3 criteria that need to be considered: Junction temperature, gate curren ...
... temperature of 200°C. All 12 devices showed maximum degradation <0.25dB after 500 hours. Gate current was negative for all of these devices during the test. For these devices to be used past the 1dB compression point, there are 3 criteria that need to be considered: Junction temperature, gate curren ...
TMP17 数据手册DataSheet 下载
... the correct grade for any given application can easily be chosen for the overall level of accuracy required. They are the calibration accuracy at +25ⴗC and the error over temperature from –40ⴗC to +105ⴗC. These specifications correspond to the actual error the user would see if the current output of ...
... the correct grade for any given application can easily be chosen for the overall level of accuracy required. They are the calibration accuracy at +25ⴗC and the error over temperature from –40ⴗC to +105ⴗC. These specifications correspond to the actual error the user would see if the current output of ...
Word
... secondary connectors. Longer stud lengths may be required for user-supplied secondary connectors. Larger thread size or length, or both, may be required if materials other than copper are used. Stud thread sizes are in inches only 6 of 10 • April 2016 • Supersedes August 2012 (G201-20-1) ©2016 Eaton ...
... secondary connectors. Longer stud lengths may be required for user-supplied secondary connectors. Larger thread size or length, or both, may be required if materials other than copper are used. Stud thread sizes are in inches only 6 of 10 • April 2016 • Supersedes August 2012 (G201-20-1) ©2016 Eaton ...
Hierarchical Control and an Overview of the Control and
... dynamics in the microgrid, which mostly lacks a significant amount of rotating inertia, the primary controller should be fast, i.e., in time scales of milliseconds. Also, for reliability reasons, communication is often avoided in the primary control, similar with the conventional grid control. Hence ...
... dynamics in the microgrid, which mostly lacks a significant amount of rotating inertia, the primary controller should be fast, i.e., in time scales of milliseconds. Also, for reliability reasons, communication is often avoided in the primary control, similar with the conventional grid control. Hence ...
MAX1566/MAX1567 Six-Channel, High-Efficiency, Digital Camera Power Supplies General Description
... Six-Channel, High-Efficiency, Digital Camera Power Supplies (VPVSU = VPV = VPVM = VPVSD = VINDL2 = 3.6V, TA = 0°C to +85°C, unless otherwise noted.) ...
... Six-Channel, High-Efficiency, Digital Camera Power Supplies (VPVSU = VPV = VPVM = VPVSD = VINDL2 = 3.6V, TA = 0°C to +85°C, unless otherwise noted.) ...
PD166013T1J Data Sheet INTELLIGENT POWER DEVICE
... Short circuit protection Shutdown by over current detection and over load detection Over temperature protection Shutdown with auto-restart on cooling Built-in diagnostic function Proportional load current sensing Defined fault signal in case of abnormal load condition Loss of ground ...
... Short circuit protection Shutdown by over current detection and over load detection Over temperature protection Shutdown with auto-restart on cooling Built-in diagnostic function Proportional load current sensing Defined fault signal in case of abnormal load condition Loss of ground ...
Laboratory and Field Test of Movable Conduction-Cooled
... are paralleled through current-sharing inductance which limits the circulating current caused by inconsistence of instantaneous voltage. Each inductor is 15 mH with resistance of less than 30 mΩ. There is also a filter circuit at the ac side of each converter. The single phase filter capacitance is ...
... are paralleled through current-sharing inductance which limits the circulating current caused by inconsistence of instantaneous voltage. Each inductor is 15 mH with resistance of less than 30 mΩ. There is also a filter circuit at the ac side of each converter. The single phase filter capacitance is ...
Using Electrostatic Discharge Test Method for Full
... tunneling or both. At high voltages, the applied electric field could reach to a sufficient strength to cause an onset of multiple impact ionizations. This results an avalanche of dielectric breakdown across the insulator [8]. These three conduction mechanisms would cause the overall electrical prop ...
... tunneling or both. At high voltages, the applied electric field could reach to a sufficient strength to cause an onset of multiple impact ionizations. This results an avalanche of dielectric breakdown across the insulator [8]. These three conduction mechanisms would cause the overall electrical prop ...
OPA843 Wideband, Low Distortion, Medium Gain, Voltage-Feedback OPERATIONAL AMPLIFIER DESCRIPTION
... The OPA843’s combination of speed and dynamic range is useful in a wide variety of application circuits, as long as simple guidelines common to all high-speed amplifiers are observed. For example, good power-supply decoupling, as shown in Figure 1, is essential to achieve the lowest possible harmoni ...
... The OPA843’s combination of speed and dynamic range is useful in a wide variety of application circuits, as long as simple guidelines common to all high-speed amplifiers are observed. For example, good power-supply decoupling, as shown in Figure 1, is essential to achieve the lowest possible harmoni ...
Research on the electrostatic induction feeding ECM The
... The electrostatic induction feeding method is used for micro-electrochemical machining (micro-ECM) to improve the machining accuracy. Principle of electrostatic induction feeding ECM The electrostatic induction feeding method is shown in Fig. 1. The power supply is coupled with the tool electrode by ...
... The electrostatic induction feeding method is used for micro-electrochemical machining (micro-ECM) to improve the machining accuracy. Principle of electrostatic induction feeding ECM The electrostatic induction feeding method is shown in Fig. 1. The power supply is coupled with the tool electrode by ...
MAX6629–MAX6632 12-Bit + Sign Digital Temperature Sensors with Serial Interface General Description
... The high resolution of the MAX6629–MAX6632 makes them especially useful in thermal control loops, HVAC systems, or in any system where quick anticipation of temperature trends is useful. The MAX6629–MAX6632 can produce temperature data in excess of +150°C, although they are specified for a maximum o ...
... The high resolution of the MAX6629–MAX6632 makes them especially useful in thermal control loops, HVAC systems, or in any system where quick anticipation of temperature trends is useful. The MAX6629–MAX6632 can produce temperature data in excess of +150°C, although they are specified for a maximum o ...
AC Sources - Operating 3.8.1 3.8 ELECTRICAL POWER SYSTEMS
... When modified start procedures are not used, the time, voltage, and frequency tolerances of SR 3.8.1.7 must be met. --------------------------------------------------------------------31 days Verify each EDG starts from standby conditions and achieves steady state voltage ≥ 6555 V and ≤ 7260 V, and ...
... When modified start procedures are not used, the time, voltage, and frequency tolerances of SR 3.8.1.7 must be met. --------------------------------------------------------------------31 days Verify each EDG starts from standby conditions and achieves steady state voltage ≥ 6555 V and ≤ 7260 V, and ...
Annexure 2 (Differences with Answer Key on LDCE for
... Wrong Answer: Correct answer C: (Package type used for large area and Central Air-condition System used in very large area ) Package air-conditioning can be considered as the bigger versions of the room airconditioner and are used for air-conditioning loads beyond the capacity range of the room air- ...
... Wrong Answer: Correct answer C: (Package type used for large area and Central Air-condition System used in very large area ) Package air-conditioning can be considered as the bigger versions of the room airconditioner and are used for air-conditioning loads beyond the capacity range of the room air- ...
LM3875 Gainclone - Building Instructions
... The first thing we do before connecting any speakers to the amp is measuring the DC offset. This can be done directly at the binding posts with no load connected. If the potentiometer is installed, the offset will vary depending on volume setting. This particular amp (right channel) measures 32mV of ...
... The first thing we do before connecting any speakers to the amp is measuring the DC offset. This can be done directly at the binding posts with no load connected. If the potentiometer is installed, the offset will vary depending on volume setting. This particular amp (right channel) measures 32mV of ...
"Is My UPS Distribution System Coordinated?
... 11. UPS internal fuse/circuit breaker configurations vary, and the specifics must be confirmed with each manufacturer. Also, the manufacturer should confirm the Alternate Source fault magnitude does not exceed the UPS Alternate Source rating capabilities. 12. When the UPS internal fuses are the sing ...
... 11. UPS internal fuse/circuit breaker configurations vary, and the specifics must be confirmed with each manufacturer. Also, the manufacturer should confirm the Alternate Source fault magnitude does not exceed the UPS Alternate Source rating capabilities. 12. When the UPS internal fuses are the sing ...