
A Robust Solution for 100-Amp Hot Swap of 12
... cap charging current is limited below a pre-determined level. There are of course variants of each type. Traditional constant-current controllers are beneficial in that they offer very predictable and repeatable current limiting, regardless of variations in input voltage or load capacitance, or the ...
... cap charging current is limited below a pre-determined level. There are of course variants of each type. Traditional constant-current controllers are beneficial in that they offer very predictable and repeatable current limiting, regardless of variations in input voltage or load capacitance, or the ...
section 265000 - lighting
... approved study, prior to energization of electrical equipment including but not limited to switchgears, switchboards, panelboards, and motor control centers. ...
... approved study, prior to energization of electrical equipment including but not limited to switchgears, switchboards, panelboards, and motor control centers. ...
MP1720 - Monolithic Power System
... and gets the input differential voltage, which would be combined with the DC bias voltage to generate the complementary voltage. The complementary voltage is compared with the sawtooth waveform. The output of the comparators (U2, U3) would trip when the input magnitude of the sawtooth exceeds the co ...
... and gets the input differential voltage, which would be combined with the DC bias voltage to generate the complementary voltage. The complementary voltage is compared with the sawtooth waveform. The output of the comparators (U2, U3) would trip when the input magnitude of the sawtooth exceeds the co ...
Electrical Safety Policy
... employee works on or near them, unless deenergizing will introduce additional or increased hazards or is not feasible due to equipment design or operational limitations (See below for examples). Live parts that operate at less than 50 volts to ground need not be deenergized if there will be no incre ...
... employee works on or near them, unless deenergizing will introduce additional or increased hazards or is not feasible due to equipment design or operational limitations (See below for examples). Live parts that operate at less than 50 volts to ground need not be deenergized if there will be no incre ...
New 4.5 kV IGBT and diode chip set for HVDC
... reactive-current control due to the turn-on and turn-off capability of the IGBT as well as superior performance in case of AC-grid faults. For high voltage applications a large number of semiconductors needed to be connected in series and simultaneous switching with high accuracy. Therefore a simple ...
... reactive-current control due to the turn-on and turn-off capability of the IGBT as well as superior performance in case of AC-grid faults. For high voltage applications a large number of semiconductors needed to be connected in series and simultaneous switching with high accuracy. Therefore a simple ...
Mitigator Loop Coil - Triplett Test Equipment
... customer. The strength of the Loop Coil’s signal WILL NOT lead the craftsperson to the equipment creating the harmonic currents. (If direct access to the customer’s load(s) is obtainable, it may be possible to measure increased harmonic output in the vicinity of the equipment.) In our example, the r ...
... customer. The strength of the Loop Coil’s signal WILL NOT lead the craftsperson to the equipment creating the harmonic currents. (If direct access to the customer’s load(s) is obtainable, it may be possible to measure increased harmonic output in the vicinity of the equipment.) In our example, the r ...
Surge Protection
... •• Mersen developed the first surge protection device to pass UL 1449 3rd edition safety requirements. •• All Mersen SPDs feature our Thermally Protected MOV (TPMOV®) technology, a fail safe surge protection solution without the need for additional upstream protection. •• The Surge-Trap® product lin ...
... •• Mersen developed the first surge protection device to pass UL 1449 3rd edition safety requirements. •• All Mersen SPDs feature our Thermally Protected MOV (TPMOV®) technology, a fail safe surge protection solution without the need for additional upstream protection. •• The Surge-Trap® product lin ...
High Power Flyback Controller with Primary
... Open Frame SMPS for Industrial, Printer, White Goods, LCD Monitors Energy Efficient AC-DC Supplies for Nominal Power 10-W to 65-W, (with up to 200% transient peak power) ...
... Open Frame SMPS for Industrial, Printer, White Goods, LCD Monitors Energy Efficient AC-DC Supplies for Nominal Power 10-W to 65-W, (with up to 200% transient peak power) ...
Institutionen för systemteknik Biasing for high linearity base-station pre-driver Department of Electrical Engineering
... Chapter 3- Background to The RF Power Amplifiers: an overview in RF power amplifier fundamentals is studied. Define the nonlinearity and metrics to measure the linearity of RF power amplifiers. Subsequently short summery of linearization techniques in RFPA is investigated. Some device technologies a ...
... Chapter 3- Background to The RF Power Amplifiers: an overview in RF power amplifier fundamentals is studied. Define the nonlinearity and metrics to measure the linearity of RF power amplifiers. Subsequently short summery of linearization techniques in RFPA is investigated. Some device technologies a ...
1. Mechanical Joining Processes
... • The greater the amperage flowing through the resistance (air gap)--the greater the heat. • The electrode also has resistance. • Excessive amperage for the diameter of the electrode over heats the electrode. • Insufficient amperage for the diameter of electrode makes electrode hard to start. ...
... • The greater the amperage flowing through the resistance (air gap)--the greater the heat. • The electrode also has resistance. • Excessive amperage for the diameter of the electrode over heats the electrode. • Insufficient amperage for the diameter of electrode makes electrode hard to start. ...
SEM-ZERO - Zapi Inc
... For the optimum chopper performance, the cables to the battery should be run side by side and be as short as possible. 3.2 CONTACTORS A Line Contactor, designed for Continuous Operation should be installed. This contactor should be fitted with a coil corresponding to the battery voltage. The current ...
... For the optimum chopper performance, the cables to the battery should be run side by side and be as short as possible. 3.2 CONTACTORS A Line Contactor, designed for Continuous Operation should be installed. This contactor should be fitted with a coil corresponding to the battery voltage. The current ...
μ PA2379T1P Data Sheet
... The diode connected between the gate and source of the transistor serves as a protector against ESD. When this device actually used, an additional protection circuit is externally required if a voltage exceeding the rated voltage may be applied to this device. ...
... The diode connected between the gate and source of the transistor serves as a protector against ESD. When this device actually used, an additional protection circuit is externally required if a voltage exceeding the rated voltage may be applied to this device. ...
Evaluates: MAX17094 MAX17094 Evaluation Kit General Description Features
... logic. Each buffer outputs the voltage on the GOFF pin (set through JU1) when its respective input is logic-low. Each buffer (Y2–Y6) outputs the voltage-on GON1 (set through JU3) when its respective input is logic-high. Similarly, Y7 and Y8 output the voltage on GON2 (set through JU4). The seven swi ...
... logic. Each buffer outputs the voltage on the GOFF pin (set through JU1) when its respective input is logic-low. Each buffer (Y2–Y6) outputs the voltage-on GON1 (set through JU3) when its respective input is logic-high. Similarly, Y7 and Y8 output the voltage on GON2 (set through JU4). The seven swi ...
Zahn, M., L. Antis, and J. Mescua, Computation Methods for One Dimensional Bipolar Charge Injection IEEE Transactions on Industry Applications IA-24, No. 3, pp. 411-421, May-June 1988
... A bsfruct-Kerr electro-optic field-mapping measurements have shown strong space charge effects in high-voltage stressed dielectrics, where the magnitude and sign of injected charge depends on electrode material. With appropriate choice of electrode material combinations atid voltage polarity it is p ...
... A bsfruct-Kerr electro-optic field-mapping measurements have shown strong space charge effects in high-voltage stressed dielectrics, where the magnitude and sign of injected charge depends on electrode material. With appropriate choice of electrode material combinations atid voltage polarity it is p ...
Electrical Safety in the Workplace
... removal, or addition of electrical or mechanical components Examples include: Replacing a duplex outlet, light switch, fluorescent fixture ballast, fuses, circuit breakers Drilling or punching holes in a live panelboard Pulling conductors into a live panelboard ...
... removal, or addition of electrical or mechanical components Examples include: Replacing a duplex outlet, light switch, fluorescent fixture ballast, fuses, circuit breakers Drilling or punching holes in a live panelboard Pulling conductors into a live panelboard ...
MAX16025–MAX16030 Dual-/Triple-/Quad-Voltage, Capacitor- Adjustable, Sequencing/Supervisory Circuits General Description
... small TQFN package. These devices offer enormous design flexibility as they allow fixed and adjustable thresholds to be selected through logic inputs and provide sequence timing through small external capacitors. These versatile devices are ideal for use in a wide variety of multivoltage application ...
... small TQFN package. These devices offer enormous design flexibility as they allow fixed and adjustable thresholds to be selected through logic inputs and provide sequence timing through small external capacitors. These versatile devices are ideal for use in a wide variety of multivoltage application ...
Installation Manual
... To install circuit breakers, first remove two screws securing faceplate to front of unit (see Figure 6a). Remove faceplate to gain access to circuit breaker positions. Push circuit breaker into one of six positions. Circuit breaker is fully seated when faceplate sits flat against front of chassis. S ...
... To install circuit breakers, first remove two screws securing faceplate to front of unit (see Figure 6a). Remove faceplate to gain access to circuit breaker positions. Push circuit breaker into one of six positions. Circuit breaker is fully seated when faceplate sits flat against front of chassis. S ...
AN-600 Understanding Latch-Up in Advanced CMOS Logic AN- 600
... may result. Again, any means to prevent any of these conditions from being satisfied will protect the circuit from exhibiting sustained latch-up. The prevention of biasing the bipolars into the active region and the limiting of the current which may be supplied by the network are the two factors whi ...
... may result. Again, any means to prevent any of these conditions from being satisfied will protect the circuit from exhibiting sustained latch-up. The prevention of biasing the bipolars into the active region and the limiting of the current which may be supplied by the network are the two factors whi ...
Not Used - Michigan State University
... Primary cable shall be three, minimum size no. 2 AWG, 1/C, 15KV, shielded cable. Cable construction shall be uncoated soft or annealed copper, strand shield, ethylene propylene rubber insulation (133% insulation level), semiconducting insulation shield with 26-#14 copper wires wound over shield, and ...
... Primary cable shall be three, minimum size no. 2 AWG, 1/C, 15KV, shielded cable. Cable construction shall be uncoated soft or annealed copper, strand shield, ethylene propylene rubber insulation (133% insulation level), semiconducting insulation shield with 26-#14 copper wires wound over shield, and ...