MAX9987/MAX9988 +14dBm to +20dBm LO Buffers/Splitters with ±1dB Variation General Description
... The MAX9987/MAX9988 LO amplifiers/splitters each consist of a single input amplifier, a two-way passive power splitter, two separate output amplifiers, as well as a third buffer amplifier to drive the LO’s PLL. The bias currents for the amplifiers are adjustable through off-chip resistors. This allo ...
... The MAX9987/MAX9988 LO amplifiers/splitters each consist of a single input amplifier, a two-way passive power splitter, two separate output amplifiers, as well as a third buffer amplifier to drive the LO’s PLL. The bias currents for the amplifiers are adjustable through off-chip resistors. This allo ...
DIGITAL AC POWER MONITOR DSP- OSI
... Only hexadecimal characters (0-9, A-F) are allowed. CMD A single character command for which there is a defined response. DATA Information associated with the command, where required. ETX An ASCII end-of-text control character, 03 Hex, control C, (^C). CR An ASCII carriage return character, 0D Hex. ...
... Only hexadecimal characters (0-9, A-F) are allowed. CMD A single character command for which there is a defined response. DATA Information associated with the command, where required. ETX An ASCII end-of-text control character, 03 Hex, control C, (^C). CR An ASCII carriage return character, 0D Hex. ...
Digital dimmable ballasts for fluorescent lamps ECO
... Intelligent Voltage Guard is the name of the new electronic monitor from Tridonic. This innovative feature of the PCA family of control gear from Tridonic immediately shows if the mains voltage rises above certain thresholds. Measures can then be taken quickly to prevent damage to the control gear. ...
... Intelligent Voltage Guard is the name of the new electronic monitor from Tridonic. This innovative feature of the PCA family of control gear from Tridonic immediately shows if the mains voltage rises above certain thresholds. Measures can then be taken quickly to prevent damage to the control gear. ...
Neutral Point Clamped and Cascaded H
... harmonic distortion, switch stress and complexity of the topology. It is found that though a cascaded inverter needs less overall components when compared to neutral point clamped inverter, yet both the inverter topologies carries the same stress across their switches and produce an almost the same ...
... harmonic distortion, switch stress and complexity of the topology. It is found that though a cascaded inverter needs less overall components when compared to neutral point clamped inverter, yet both the inverter topologies carries the same stress across their switches and produce an almost the same ...
Electrical measurements
... Moreover, we have not said anything about the concentration of charge carriers, which depends on materials, temperature and composition. While these are the interesting parameters for us as chemists, physicists or materials scientists, this course is not so much about that. Instead it is about the m ...
... Moreover, we have not said anything about the concentration of charge carriers, which depends on materials, temperature and composition. While these are the interesting parameters for us as chemists, physicists or materials scientists, this course is not so much about that. Instead it is about the m ...
25530 Evolve New Style V4
... The perfect enhancement for any sliding door application With three systems available - the Evolve 60, Evolve 80 and Evolve 80 Sim Kit - that can deliver automation to pocket, single and double sliding doors weighing up to 80kg. Doors can be of a flush, panelled or glazed construction. Evolve is per ...
... The perfect enhancement for any sliding door application With three systems available - the Evolve 60, Evolve 80 and Evolve 80 Sim Kit - that can deliver automation to pocket, single and double sliding doors weighing up to 80kg. Doors can be of a flush, panelled or glazed construction. Evolve is per ...
Application Notes Relays - ZETTLER electronics GmbH
... Coil resistance DC resistance of a relay coil at reference temperature (+20 °C). Higher coil temperatures increase the resistance value by 0.4 % per Kelvin (0.4 % per °C); e.g. at 40 °C the coil resistance is increased by 8 %. Thus the coil voltage has to be adapted accordingly (➝ operate value). Wi ...
... Coil resistance DC resistance of a relay coil at reference temperature (+20 °C). Higher coil temperatures increase the resistance value by 0.4 % per Kelvin (0.4 % per °C); e.g. at 40 °C the coil resistance is increased by 8 %. Thus the coil voltage has to be adapted accordingly (➝ operate value). Wi ...
AC Sources - Operating 3.8.1 3.8 ELECTRICAL POWER SYSTEMS
... When modified start procedures are not used, the time, voltage, and frequency tolerances of SR 3.8.1.7 must be met. --------------------------------------------------------------------31 days Verify each EDG starts from standby conditions and achieves steady state voltage ≥ 6555 V and ≤ 7260 V, and ...
... When modified start procedures are not used, the time, voltage, and frequency tolerances of SR 3.8.1.7 must be met. --------------------------------------------------------------------31 days Verify each EDG starts from standby conditions and achieves steady state voltage ≥ 6555 V and ≤ 7260 V, and ...
D43052327
... the range 1-40 GHz is very high than the other decreased power consumption. Since there are essentially switches. no moving parts the electronic system can be made very reliable. As a result, MEMS is revolutionizing the (5) Ability to be integrated with other electronic devices with excellent linear ...
... the range 1-40 GHz is very high than the other decreased power consumption. Since there are essentially switches. no moving parts the electronic system can be made very reliable. As a result, MEMS is revolutionizing the (5) Ability to be integrated with other electronic devices with excellent linear ...
STTH60W03C
... The STTH60W03C uses ST Turbo 2 300 V technology. It is especially suited to be used for DC/DC and DC/AC converters in secondary stage of MIG/MMA/TIG welding machine. Housed in ST's TO-247, this device offers high power integration for all welding machines and industrial applications. ...
... The STTH60W03C uses ST Turbo 2 300 V technology. It is especially suited to be used for DC/DC and DC/AC converters in secondary stage of MIG/MMA/TIG welding machine. Housed in ST's TO-247, this device offers high power integration for all welding machines and industrial applications. ...
MAX4370 Current-Regulating Hot-Swap Controller with DualSpeed/BiLevel Fault Protection General Description
... During start-up, the slow comparator is disabled and current limiting is provided two different ways: 1) Slow ramping of the current to the load by controlling the external MOSFET gate voltage. 2) Limiting the current to the load by regulating the voltage across the external current-sense resistor. ...
... During start-up, the slow comparator is disabled and current limiting is provided two different ways: 1) Slow ramping of the current to the load by controlling the external MOSFET gate voltage. 2) Limiting the current to the load by regulating the voltage across the external current-sense resistor. ...
Word
... secondary connectors. Longer stud lengths may be required for user-supplied secondary connectors. Larger thread size or length, or both, may be required if materials other than copper are used. Stud thread sizes are in inches only 6 of 10 • April 2016 • Supersedes August 2012 (G201-20-1) ©2016 Eaton ...
... secondary connectors. Longer stud lengths may be required for user-supplied secondary connectors. Larger thread size or length, or both, may be required if materials other than copper are used. Stud thread sizes are in inches only 6 of 10 • April 2016 • Supersedes August 2012 (G201-20-1) ©2016 Eaton ...