ARCAT spec 262600 2009-9-15
... The relays shall be Allen-Bradley 700CF relays (2 form C contacts, 2N.O. & 2N.C.). The relay contacts shall be rated for 115 VAC/30 VDC, 5.0 A resistive, 5.0 A ...
... The relays shall be Allen-Bradley 700CF relays (2 form C contacts, 2N.O. & 2N.C.). The relay contacts shall be rated for 115 VAC/30 VDC, 5.0 A resistive, 5.0 A ...
Protection Policy
... Equipment Protection Policy, or the alleged breach thereof, shall be settled by arbitration administered by the American Arbitration Association under its Commercial Arbitration Rules. You may file for arbitration at any AAA location in the United States upon the payment of the applicable filing fee ...
... Equipment Protection Policy, or the alleged breach thereof, shall be settled by arbitration administered by the American Arbitration Association under its Commercial Arbitration Rules. You may file for arbitration at any AAA location in the United States upon the payment of the applicable filing fee ...
Application Note TLE8110EE
... Coil “A” and coil “B” are magnetic linked. In principle both pairs of coils present a transformer with the translation 1:1. The strongly decreasing magnetic field induces a voltage into coil “B” when current flow through coil “A” is stopped. Because of this induced voltage a reverse current flows th ...
... Coil “A” and coil “B” are magnetic linked. In principle both pairs of coils present a transformer with the translation 1:1. The strongly decreasing magnetic field induces a voltage into coil “B” when current flow through coil “A” is stopped. Because of this induced voltage a reverse current flows th ...
ORIGINATION FORM
... operation or failure status. Hardwired type units shall also include one set of dry contacts to transmit this status information to other monitoring systems. Ensure that these units have internal fuse protection and provide both normal mode (L-N) and common mode (L+N-G) protection. 785-12.4.4 TVSS D ...
... operation or failure status. Hardwired type units shall also include one set of dry contacts to transmit this status information to other monitoring systems. Ensure that these units have internal fuse protection and provide both normal mode (L-N) and common mode (L+N-G) protection. 785-12.4.4 TVSS D ...
Old Company Name in Catalogs and Other Documents
... All information included in this document is current as of the date this document is issued. Such information, however, is subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm the latest product information with a Renes ...
... All information included in this document is current as of the date this document is issued. Such information, however, is subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm the latest product information with a Renes ...
750kVA SG Series UPS with eBoost Technology
... Each UPS module shall contain an inductor in the internal bypass circuit. The purpose of this inductor shall be to balance the impedances of the paralleled UPS bypass circuits and reduce or eliminate the need to equalize cable lengths. This inductor shall also couple with the normal UPS output filte ...
... Each UPS module shall contain an inductor in the internal bypass circuit. The purpose of this inductor shall be to balance the impedances of the paralleled UPS bypass circuits and reduce or eliminate the need to equalize cable lengths. This inductor shall also couple with the normal UPS output filte ...
A750 Series, 105°C
... As an environmentally conscious company, KEMET is working continuously with improvements concerning the environmental effects of both our capacitors and their production. In Europe (RoHS Directive) and in some other geographical areas like China, legislation has been put in place to prevent the use ...
... As an environmentally conscious company, KEMET is working continuously with improvements concerning the environmental effects of both our capacitors and their production. In Europe (RoHS Directive) and in some other geographical areas like China, legislation has been put in place to prevent the use ...
Electrical Installations Lab AEL-1 Advanced Electrical Laboratories (AEL-LABS):
... This software has been designed to acquire different signals to know the state of the processes. For example, to study the dynamic characteristics of an induction squirrel cage motor, the data acquisition system allows to monitor, in real time, the mechanical torque curves, speed, electrical power, ...
... This software has been designed to acquire different signals to know the state of the processes. For example, to study the dynamic characteristics of an induction squirrel cage motor, the data acquisition system allows to monitor, in real time, the mechanical torque curves, speed, electrical power, ...
Tailoring GMAW Waveforms for Specific Applications
... information about their use of our products. We respond to our customers based on the best information in our possession at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes no liability, with respect to such information or advice. We expressly disclai ...
... information about their use of our products. We respond to our customers based on the best information in our possession at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes no liability, with respect to such information or advice. We expressly disclai ...
File Size: KB Bulletin
... Subject: When using speakers in which the actual impedance is very low and the input signal is a very high level, power down is activated. Reason: In some popular expensive speakers (such as some models of B&W speakers), the actual impedance seems to be lower than the catalog spec (8 ohms or 6 ohms) ...
... Subject: When using speakers in which the actual impedance is very low and the input signal is a very high level, power down is activated. Reason: In some popular expensive speakers (such as some models of B&W speakers), the actual impedance seems to be lower than the catalog spec (8 ohms or 6 ohms) ...
ATTACHMENT 65001.08 INSPECTION OF ITAAC-RELATED INSTALLATION OF ELECTRIC COMPONENTS AND SYSTEMS
... For purposes of this procedure, ECS consist of those items of the facility that are designed to supply, use, control, transform, condition, or interrupt electric power, except for the electric cables. It does not cover instrumentation and controls or valves, although electrical input to valves is in ...
... For purposes of this procedure, ECS consist of those items of the facility that are designed to supply, use, control, transform, condition, or interrupt electric power, except for the electric cables. It does not cover instrumentation and controls or valves, although electrical input to valves is in ...
ZLLS350 Description Mechanical Data
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
ZXMS6004SG Features and Benefits Product Summary
... VIN = +3V VIN = +5V VIN = +5V VIN = +3V, ID = 0.5A VIN = +5V, ID = 0.5A VIN = 3V; TA = 25C VIN = 5V; TA = 25C VIN = 3V; TA = 25C VIN = 5V; TA = 25C VIN = +3V VIN = +5V ...
... VIN = +3V VIN = +5V VIN = +5V VIN = +3V, ID = 0.5A VIN = +5V, ID = 0.5A VIN = 3V; TA = 25C VIN = 5V; TA = 25C VIN = 3V; TA = 25C VIN = 5V; TA = 25C VIN = +3V VIN = +5V ...
AA36155160
... Obviously, the resistive ballast incurs large power loss and significantly reduces the system efficiency. Fortunately, most discharge lamps are operated in alternating-current (AC) circuits so that inductive or capacitive impedance can be used to provide current limitation. AC operation also balance ...
... Obviously, the resistive ballast incurs large power loss and significantly reduces the system efficiency. Fortunately, most discharge lamps are operated in alternating-current (AC) circuits so that inductive or capacitive impedance can be used to provide current limitation. AC operation also balance ...
CYB_PDU 500kVA_Guideform Spec
... case circuit breaker sized for 125% of the PDM full load current rating. The main input breaker rating for the 500kVA PDM shall be 800 amps. The system's input main circuit breaker (s) shall contain a 24 VDC shunt trip mechanism which shall be interfaced to the local Emergency Power Off (EPO) pushbu ...
... case circuit breaker sized for 125% of the PDM full load current rating. The main input breaker rating for the 500kVA PDM shall be 800 amps. The system's input main circuit breaker (s) shall contain a 24 VDC shunt trip mechanism which shall be interfaced to the local Emergency Power Off (EPO) pushbu ...
AD7273/AD7274 3 MSPS, 10-/12-Bit ADCs in 8
... serial data stream. The bits are clocked out on the falling edge of the SCLK input. The data stream from the AD7274 consists of two leading zeros followed by the 12 bits of conversion data and two trailing zeros, provided MSB first. The data stream from the AD7273 consists of two leading zeros follo ...
... serial data stream. The bits are clocked out on the falling edge of the SCLK input. The data stream from the AD7274 consists of two leading zeros followed by the 12 bits of conversion data and two trailing zeros, provided MSB first. The data stream from the AD7273 consists of two leading zeros follo ...
General Description Features
... and PWR- PCB pads. When a wall adapter power source is detected, it always takes precedence over the PSE source, allowing the wall adapter to power the EV kit. Warning: The EV kit is designed to operate with high voltages. Dangerous voltages are present on this EV kit and on equipment connected to i ...
... and PWR- PCB pads. When a wall adapter power source is detected, it always takes precedence over the PSE source, allowing the wall adapter to power the EV kit. Warning: The EV kit is designed to operate with high voltages. Dangerous voltages are present on this EV kit and on equipment connected to i ...