• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
PAM8303C Description Pin Assignments
PAM8303C Description Pin Assignments

... harmonic distortion (THD) as low as possible. Power supply decoupling also prevents the oscillations causing by long lead length between the amplifier and the speaker. The optimum decoupling is achieved by using two different types of capacitors that target on different types of noise on the power s ...
Application Note No. 7038
Application Note No. 7038

Enhanced Energy Deposition Efficiency of Glow Treatment , Senior Member, IEEE
Enhanced Energy Deposition Efficiency of Glow Treatment , Senior Member, IEEE

... Publisher Item Identifier S 0093-3813(00)03663-8. ...
Electronic Systems Protection Electronic Systems Protection
Electronic Systems Protection Electronic Systems Protection

... Furse Surge Protective Devices are widely specified and offer industry-leading voltage protection levels to ensure the continuous operation of critical electronic systems, such as those found in data centres, hospitals and automated process control. Used with Furse data / telecom SPDs, they form par ...
ba50/75/100 series
ba50/75/100 series

... current range is not limited. Closing each switch effectively limits the output range of the amplifier by a factor associated with that switch. For example closing only SW1-4 (54%) on a BA50 limits the output current to 27 Amp. Therefore, a 10 Volt input signal would produce a 27 Amp output; similar ...
The Lineman`s and Cableman`s Field Manual
The Lineman`s and Cableman`s Field Manual

SURGELOGIC™ TVSS Surge Protective Devices
SURGELOGIC™ TVSS Surge Protective Devices

... Utility industry experts estimate that problems resulting from transient voltage surges cost U.S. companies a stunning $26 billion annually.That figure not only includes the high price of direct damage to electrical distribution systems, electronic equipment, software and tools, but also the crippli ...
INA220-Q1 Automotive Grade, 26-V, I2C
INA220-Q1 Automotive Grade, 26-V, I2C

... (Configuration register, SADC bits). The device then converts the bus voltage up to the number set in the bus voltage averaging (Configuration register, BADC bits). The Mode control in the Configuration register also permits selecting modes to convert only voltage or current, either continuously or ...
PSIM User Manual
PSIM User Manual

... If the zener diode is positively biased, it behaviors as a regular diode. When it is reverse biased, it will block the conduction as long as the cathode-anode voltage VKA is less than the breakdown voltage VB. Otherwise, the voltage VKA will be clamped to VB. ...
Powersub™ Vacuum Substation Circuit Breaker
Powersub™ Vacuum Substation Circuit Breaker

... performing the installation, operation, and maintenance steps provided. Electrical equipment should be installed and serviced only by qualified personnel. Qualified personnel should establish procedures that ensure the safety of personnel and equipment. The Type FVR circuit breaker is designed for o ...
ARCAT spec 262600 2009-9-15
ARCAT spec 262600 2009-9-15

... The relays shall be Allen-Bradley 700CF relays (2 form C contacts, 2N.O. & 2N.C.). The relay contacts shall be rated for 115 VAC/30 VDC, 5.0 A resistive, 5.0 A ...
Metal halide lamps
Metal halide lamps

FINAL SAFETY ANALYSIS REPORT CHAPTER 8 ELECTRIC POWER CCNPP Unit 3
FINAL SAFETY ANALYSIS REPORT CHAPTER 8 ELECTRIC POWER CCNPP Unit 3

... Chapel. Approximately 3 mi (5 km) of circuit 5072 utilize the existing 500 kV line that was previously modified to avoid any crossings of the 500 kV lines. The transmission system consists of two circuits. One circuit consists of two separate three-phase 500 kV transmission lines (single right-of-wa ...
Transistor Circuits
Transistor Circuits

... Connecting a transistor to the output from an IC Most ICs cannot supply large output currents so it may be necessary to use a transistor to switch the larger current required for output devices such as lamps, motors and relays. The 555 timer IC is unusual because it can supply a relatively large cur ...
SBLE, SBM, SBH Technical Manual
SBLE, SBM, SBH Technical Manual

... are usually required to sustain electrical loads for between 30 minutes to 3 hours or for “mixed” loads which involve a mixture of high and low discharge rates. The applications can have frequent or infrequent discharges. The range is typically used in power backup applications. ...
operation manual
operation manual

... Power-factor improvement circuit The power-factor improvement circuit reduces the effects of harmonic currents on the power line. High efficiency The high power conversion efficiency reduces the cost of power and the cost of heat radiation design during system configuration. Communication functions ...
radiac set an/pdr-56f (nsn 6665-01-113-9530)
radiac set an/pdr-56f (nsn 6665-01-113-9530)

... the radiacmeter and the main, auxiliary, and x-ray probes. These items and their circuitry are laid out on the block diagram (fig. 2-1) with the direction of signal flow from left to right. The signal starts in the probe (main, auxiliary, or x-ray) and ends up as both a meter indication and a sound ...
Noise and Relative Photon Detection Efficiency
Noise and Relative Photon Detection Efficiency

... Compared to photodiodes, APDs use free negative charged carriers, which gain enough energy in the accelerating field E to create electron-hole pairs themselves. This process is visualized in figure 3.2. Reverse-biased diodes can achieve amplification of the signal up to 50 − 200 compared to regular ...
Pic Programmer by Myke Predko
Pic Programmer by Myke Predko

BTPWE 504 Electrical Machines II
BTPWE 504 Electrical Machines II

FZT558 Features Mechanical Data
FZT558 Features Mechanical Data

... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
1 - Fel Zcu - Západočeská univerzita
1 - Fel Zcu - Západočeská univerzita

... PDEV means Partial Discharge Extinction Voltage. It can be also marked as Ue (kV). PDEV is the voltage when no PD current pulses can be recorded. It is also necessary to continuously decrease the test voltage in this case. In practise the test procedure is as follows. When PDIV is reached, test volt ...
DEE 403 Electrical Machines II
DEE 403 Electrical Machines II

Application Note TLE8110EE
Application Note TLE8110EE

... Coil “A” and coil “B” are magnetic linked. In principle both pairs of coils present a transformer with the translation 1:1. The strongly decreasing magnetic field induces a voltage into coil “B” when current flow through coil “A” is stopped. Because of this induced voltage a reverse current flows th ...
BDTIC www.BDTIC.com/infineon Efficient Solutions for Industrial Motor Control and Drives
BDTIC www.BDTIC.com/infineon Efficient Solutions for Industrial Motor Control and Drives

... Energy efficiency, mobility and security are the main challenges facing modern society. Our motor control solutions address all of these needs, providing outstanding reliability, excellent quality and leadingedge innovations. This guide showcases the full range of products – from microcontrollers an ...
< 1 ... 141 142 143 144 145 146 147 148 149 ... 1640 >

Voltage optimisation

Voltage optimisation is a term given to the systematic controlled reduction in the voltages received by an energy consumer to reduce energy use, power demand and reactive power demand. While some voltage 'optimisation' devices have a fixed voltage adjustment, others electronically regulate the voltage automatically.Voltage optimisation systems are typically installed in series with the mains electrical supply to a building, allowing all its electrical equipment to benefit from an optimised supply.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report