
ULTRA SLIMPAK G168-0001 ® DC Powered AC Input Limit Alarm
... input signal status. Active DC power is indicated by an illuminated LED. If this LED is off, check DC power and the wiring connection. If the input signal is more than 110% of the full scale range, the LED will flash at 8 Hz. Below 0%, it flashes at 4 Hz. Two red LEDs indicate the relay state for ea ...
... input signal status. Active DC power is indicated by an illuminated LED. If this LED is off, check DC power and the wiring connection. If the input signal is more than 110% of the full scale range, the LED will flash at 8 Hz. Below 0%, it flashes at 4 Hz. Two red LEDs indicate the relay state for ea ...
SN75ALS162 数据资料 dataSheet 下载
... Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been de ...
... Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been de ...
Variation-Aware Supply Voltage Assignment for Simultaneous Power and Aging Optimization
... Table I shows the results of our SVA technique and the comparison between our approach and guard-banding approach/single Vdd scaling approach. All these approaches are implemented at the same voltage resolution: 20 mV. The power presented in the following is the average power during the overall circ ...
... Table I shows the results of our SVA technique and the comparison between our approach and guard-banding approach/single Vdd scaling approach. All these approaches are implemented at the same voltage resolution: 20 mV. The power presented in the following is the average power during the overall circ ...
TP-8101, TP-8102, TP-8103, TP-8124, TP-8125
... calibrated to produce 6.0 Vdc output signals at OP1 and OP2 to COM terminals when the setpoints and the temperatures at the sensing element agree. Test the power supply and output as follows: 1. Verify the wiring per the job wiring diagram. 2. Measure with a 20,000 ohm per Vdc VOM: a. Power supply 2 ...
... calibrated to produce 6.0 Vdc output signals at OP1 and OP2 to COM terminals when the setpoints and the temperatures at the sensing element agree. Test the power supply and output as follows: 1. Verify the wiring per the job wiring diagram. 2. Measure with a 20,000 ohm per Vdc VOM: a. Power supply 2 ...
LT1638/LT1639 - 1.2MHz, 0.4V/us Over-The-Top Micropower Rail-to-Rail Input and Output Op Amps
... 170μA of quiescent current per amplifier. These amplifiers are reverse battery protected and draw no current for reverse supply up to 18V. The input range of the LT1638/LT1639 includes both supplies, and a unique feature of this device is its capability to operate over the top with either or both of i ...
... 170μA of quiescent current per amplifier. These amplifiers are reverse battery protected and draw no current for reverse supply up to 18V. The input range of the LT1638/LT1639 includes both supplies, and a unique feature of this device is its capability to operate over the top with either or both of i ...
UCC3974 数据资料 dataSheet 下载
... on the MODE pin reaches 0.5 V (t1), the internal circuitry on the device is disabled and nothing happens at the outputs. As the voltage crosses 0.5 V, the internal circuitry is powered up. When the voltage crosses 1 V at t2, the outputs are enabled, allowing the buck stages to begin to charge up and ...
... on the MODE pin reaches 0.5 V (t1), the internal circuitry on the device is disabled and nothing happens at the outputs. As the voltage crosses 0.5 V, the internal circuitry is powered up. When the voltage crosses 1 V at t2, the outputs are enabled, allowing the buck stages to begin to charge up and ...
Application Note AN-6014 Green Current Mode PWM Controller FAN7602 1. Introduction www.fairchildsemi.com
... Figure 3 shows a typical start-up sequence for the FAN7602. The VCC voltage should be higher than the minimum operating voltage during the start-up to enter the steady state. If the VCC voltage is higher than 19V, the over-voltage protection function works and this is a latch protection. There is 5. ...
... Figure 3 shows a typical start-up sequence for the FAN7602. The VCC voltage should be higher than the minimum operating voltage during the start-up to enter the steady state. If the VCC voltage is higher than 19V, the over-voltage protection function works and this is a latch protection. There is 5. ...
Wang, J., Q. Yang, W. Sima, T. Yuan, and M. Zahn, A Smart Online Over-Voltage Monitoring and Identification System, Energies, 4, pp. 599-615, 2011
... 2.1. Over-Voltage Sensor The development of an over-voltage sensor is a key part of any online monitoring system. At present, the over-voltage monitoring devices used in the distribution network, are mostly based on the potential transformer system and resistor or capacitor voltage-dividing systems. ...
... 2.1. Over-Voltage Sensor The development of an over-voltage sensor is a key part of any online monitoring system. At present, the over-voltage monitoring devices used in the distribution network, are mostly based on the potential transformer system and resistor or capacitor voltage-dividing systems. ...
Contents 1 How to Read this Design Guide IVS 102 Design Guide
... subject to a short circuit on the output. A locked trip can only be cancelled by cutting off mains, removing the cause of the fault, and reconnecting the frequency converter. Restart is prevented until the trip state is cancelled by activating reset or, in some cases, by being programmed to reset au ...
... subject to a short circuit on the output. A locked trip can only be cancelled by cutting off mains, removing the cause of the fault, and reconnecting the frequency converter. Restart is prevented until the trip state is cancelled by activating reset or, in some cases, by being programmed to reset au ...
02052_rB
... The rising edge indicates the arrival of a thick detector signal and shall occur no less than 200ns before the peak amplitude is reached. The rising edge of this signal shall be less than 25 nsecs into 1-MegOhm and 10pF. ...
... The rising edge indicates the arrival of a thick detector signal and shall occur no less than 200ns before the peak amplitude is reached. The rising edge of this signal shall be less than 25 nsecs into 1-MegOhm and 10pF. ...
THS6204
... Stresses above those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to absolu ...
... Stresses above those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to absolu ...
INA125 数据资料 dataSheet 下载
... Figure 1 shows the basic connections required for operation of the INA125. Applications with noisy or high impedance power supplies may require decoupling capacitors close to the device pins as shown. The output is referred to the instrumentation amplifier reference (IAREF) terminal which is normall ...
... Figure 1 shows the basic connections required for operation of the INA125. Applications with noisy or high impedance power supplies may require decoupling capacitors close to the device pins as shown. The output is referred to the instrumentation amplifier reference (IAREF) terminal which is normall ...
比较器系列ADCMP606 数据手册DataSheet 下载
... lowest inductance return path for switching currents ensures the best possible performance in the target application. It is also important to adequately bypass the input and output supplies. Multiple high quality 0.01 μF bypass capacitors should be placed as close as possible to each of the VCCI and ...
... lowest inductance return path for switching currents ensures the best possible performance in the target application. It is also important to adequately bypass the input and output supplies. Multiple high quality 0.01 μF bypass capacitors should be placed as close as possible to each of the VCCI and ...