How to shed non-priority loads with a Compact NSX circuit breaker?
... The "reflex" load-shedding solution via a local order with Compact NSX provides: p a reduction in capital expenditure, as its purchase price is lower than that of a traditional solution: the cost of a Compact NSX with a Micrologic E trip unit (energy measurement) + SDx module is similar to the cost o ...
... The "reflex" load-shedding solution via a local order with Compact NSX provides: p a reduction in capital expenditure, as its purchase price is lower than that of a traditional solution: the cost of a Compact NSX with a Micrologic E trip unit (energy measurement) + SDx module is similar to the cost o ...
Power Quality improvement using passive shunt filter Assistant
... double tuned, high pass damped filters, etc. A single tuned filter is a series RLC circuit tuned for particular harmonic frequency, whereas double tuned filter is tuned for two harmonic frequencies. The double-tuned filter is preferred mainly in high-voltage applications, because of the reduction in ...
... double tuned, high pass damped filters, etc. A single tuned filter is a series RLC circuit tuned for particular harmonic frequency, whereas double tuned filter is tuned for two harmonic frequencies. The double-tuned filter is preferred mainly in high-voltage applications, because of the reduction in ...
SM72501 Precision, CMOS Input, RRIO, Wide Supply Range
... Electrical Table values apply only for factory testing conditions at the temperature indicated. Factory testing conditions result in very limited self-heating of the device such that TJ = TA. Parametric performance is indicated in the electrical tables under conditions of internal self-heating where ...
... Electrical Table values apply only for factory testing conditions at the temperature indicated. Factory testing conditions result in very limited self-heating of the device such that TJ = TA. Parametric performance is indicated in the electrical tables under conditions of internal self-heating where ...
BDTIC www.BDTIC.com/infineon T L E 4 9 9 8 P 3
... microcontroller). Furthermore, it is possible to attach an external lowpass filter, which allows an A/D conversion using the sensor supply voltage as a reference. The output stage is an open-drain driver pulling the output pad to low only. Therefore, the high level must be obtained by an external pu ...
... microcontroller). Furthermore, it is possible to attach an external lowpass filter, which allows an A/D conversion using the sensor supply voltage as a reference. The output stage is an open-drain driver pulling the output pad to low only. Therefore, the high level must be obtained by an external pu ...
Analog Dialogue Volume 43, Number 2, 2009
... system. While earlier systems typically needed 500 V to 1 kV of isolation, today >2 kV is generally required. The ADuM1401 digital isolator uses iCoupler®5 technology to provide the necessary isolation between the MCU and remote loads, or between the input/output module and the backplane. Three chan ...
... system. While earlier systems typically needed 500 V to 1 kV of isolation, today >2 kV is generally required. The ADuM1401 digital isolator uses iCoupler®5 technology to provide the necessary isolation between the MCU and remote loads, or between the input/output module and the backplane. Three chan ...
Electronics Lab Manual
... “Linear” devices have I-V curves that are straight lines. For many devices, the “response” or current through the device is proportional to the “input” or voltage across the device over a broad range and their I-V curves obey Ohm’s law: V = IR. ...
... “Linear” devices have I-V curves that are straight lines. For many devices, the “response” or current through the device is proportional to the “input” or voltage across the device over a broad range and their I-V curves obey Ohm’s law: V = IR. ...
CDCM1802: Clock Buffer w/Programmable Divider, LVPECL I/O +
... The inputs deploy an ESD structure protecting the inputs in case of an input voltage exceeding the rails by more than ≈0.7 V. Reverse biasing of the IC through this inputs is possible and must be prevented by limiting the input voltage < VDD. Select mode of operation. Defines the output configuratio ...
... The inputs deploy an ESD structure protecting the inputs in case of an input voltage exceeding the rails by more than ≈0.7 V. Reverse biasing of the IC through this inputs is possible and must be prevented by limiting the input voltage < VDD. Select mode of operation. Defines the output configuratio ...
Design of Single-Switch Inverters for Variable Resistance / Load
... depending on the characteristic impedance of the input tank and the load modulation range. As Appendix I demonstrates, there is no single resonant frequency fIN of LF and CF that will guarantee perfect ZVS across the entire load modulation range. In other words, for a given input tank characteristic ...
... depending on the characteristic impedance of the input tank and the load modulation range. As Appendix I demonstrates, there is no single resonant frequency fIN of LF and CF that will guarantee perfect ZVS across the entire load modulation range. In other words, for a given input tank characteristic ...
Microstepping DMOS Driver with Translator A3977
... The A3977 is a complete microstepping motor driver, with built-in translator. It is designed to operate bipolar stepper motors in full-, half-, quarter-, and eighth-step modes, with output drive capability of 35 V and ±2.5 A. The A3977 includes a fixed off-time current regulator that has the ability ...
... The A3977 is a complete microstepping motor driver, with built-in translator. It is designed to operate bipolar stepper motors in full-, half-, quarter-, and eighth-step modes, with output drive capability of 35 V and ±2.5 A. The A3977 includes a fixed off-time current regulator that has the ability ...
Noise figure considerations in the design of superhetrodyne receiver
... fi•ee ar11plifier · shunted with a resist or and therefore should not di ffer from the case for the resistor al one . In examining the case where the system consists of a generator, resistor, and noisy ar11plifier, the conc ept of a.n ttequival ent resista..r1Ce 11 to characterize the amplifier nois ...
... fi•ee ar11plifier · shunted with a resist or and therefore should not di ffer from the case for the resistor al one . In examining the case where the system consists of a generator, resistor, and noisy ar11plifier, the conc ept of a.n ttequival ent resista..r1Ce 11 to characterize the amplifier nois ...
AD13280 Dual-Channel, 12-Bit, 80 MSPS ADC with Analog Input Signal
... The AD13280 is a complete, dual-channel, signal processing solution that includes on-board amplifiers, references, ADCs, and output termination components to provide optimized system performance. The AD13280 has on-chip track-and-hold circuitry and uses an innovative multipass architecture to achiev ...
... The AD13280 is a complete, dual-channel, signal processing solution that includes on-board amplifiers, references, ADCs, and output termination components to provide optimized system performance. The AD13280 has on-chip track-and-hold circuitry and uses an innovative multipass architecture to achiev ...
ADS1605 数据资料 dataSheet 下载
... and passband ripple is less than ±0.0025dB (to 2.2MHz). Both devices offer the same outstanding performance at these speeds with a signal-to-noise ratio up to 88dB, total harmonic distortion down to −99dB, and a spurious-free dynamic range up to 101dB. For even higher-speed operation, the data rate ...
... and passband ripple is less than ±0.0025dB (to 2.2MHz). Both devices offer the same outstanding performance at these speeds with a signal-to-noise ratio up to 88dB, total harmonic distortion down to −99dB, and a spurious-free dynamic range up to 101dB. For even higher-speed operation, the data rate ...
III. Eliminating transmission line mismatch
... reflective waves are out of phase (destructive interference). For a complex load impedance, the locations of the first voltage maximum and minimum are given by: ...
... reflective waves are out of phase (destructive interference). For a complex load impedance, the locations of the first voltage maximum and minimum are given by: ...
Print this article - International Journal of Innovative Research and
... Figure 2: Impedance Matching of a resistive source and a complex load for maximum power transfer Using only one series reactive element between two equal resistive terminations creates a voltage drop that reduces the voltage across the load. Impedance Matching can eliminate or minimize the unwanted ...
... Figure 2: Impedance Matching of a resistive source and a complex load for maximum power transfer Using only one series reactive element between two equal resistive terminations creates a voltage drop that reduces the voltage across the load. Impedance Matching can eliminate or minimize the unwanted ...
Design of Single-Switch Inverters for Variable Resistance
... depending on the characteristic impedance of the input tank and the load modulation range. As Appendix I demonstrates, there is no single resonant frequency fIN of LF and CF that will guarantee perfect ZVS across the entire load modulation range. In other words, for a given input tank characteristic ...
... depending on the characteristic impedance of the input tank and the load modulation range. As Appendix I demonstrates, there is no single resonant frequency fIN of LF and CF that will guarantee perfect ZVS across the entire load modulation range. In other words, for a given input tank characteristic ...
Metal-Clad Switchgear or Metal-Enclosed
... interrupting device is a low voltage power circuit breaker, either withdrawable or stationary. It may be either manually or electrically operated, fused or unfused. Each circuit breaker is enclosed in a grounded metal compartment, but other isolation, such as between buses and cable connections, is ...
... interrupting device is a low voltage power circuit breaker, either withdrawable or stationary. It may be either manually or electrically operated, fused or unfused. Each circuit breaker is enclosed in a grounded metal compartment, but other isolation, such as between buses and cable connections, is ...