• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Solutionto QuestionBank
Solutionto QuestionBank

The Importance of the X/R Ratio in Low
The Importance of the X/R Ratio in Low

... of AC electrical systems. We must remember that a fault is a sudden event. Any time a sudden event occurs, the electrical system requires some time to adapt. Such a response is called a transient, which means that it lasts for only a short time. In AC electrical systems, impedance has two components ...
Control of a 3-phase 4-leg active power filter under non
Control of a 3-phase 4-leg active power filter under non

... instantaneous real and imaginer power have current harmonics and voltage harmonics. Consequently, the APF does not generate compensation current equal to current harmonics and gives to mains more than load harmonics than required. To overcome these limitations, the p–q theory based a new control alg ...
The Test, Usage and Maintenance of Power Switching Subsystems Kevin Paton
The Test, Usage and Maintenance of Power Switching Subsystems Kevin Paton

... and current verification of the supply. The supply used is a 35V, 8.5 amp supply so the full voltage of the supply (35V) can be verified and the current can be tested to approximately 350 mAmps. If the power supply test fails then no switch tests are run. An important aspect of having the 100 ohm lo ...
Integrated virtualization of about 300 in-house physical
Integrated virtualization of about 300 in-house physical

... of the high-voltage direct current power supply (HVDC). This will reduce power supply loss by 10–20% and achieve an eco-friendly IT platform. In the future, the remaining servers will be sequentially integrated into the new system, and we will also consider providing know-how on the use of HVDC to o ...
Eliminate Reactive Power and Increase System Efficiency of Isolated Bidirectional
Eliminate Reactive Power and Increase System Efficiency of Isolated Bidirectional

... flowing in the transformer, even for phase shift D = 0 (where output power P = 0). When V2 = nV1 , there is always a current flowing in the transformer, except for D = 0. This current contributes to the reactive power in the circuit. Fig. 2(b) shows the peak current in steady-state operation as a fu ...
Multi Range DC Power Supply  Model:  9110, 9111 1
Multi Range DC Power Supply Model: 9110, 9111 1

... panel or the wiring of permanently-installed motors. Category IV (CAT IV): Measurement instruments whose measurement inputs are meant to be connected ...
Profesor Facultad de Minas, Universidad Nacional de Colombia
Profesor Facultad de Minas, Universidad Nacional de Colombia

Question Bank - International Virtual University Campus
Question Bank - International Virtual University Campus

... Qu.21. List out main components of power supply system with a brief description. Also write the advantages of power factor improvement. Qu.22. Draw the general layout of an electrical power system and explain briefly. Qu.23. Explain clearly the difference between feeder distributer & service mains. ...
ON  THE  DESIGN  OF  LOW-POWER ... RESISTIVE  SENSORS Ramon Casanella
ON THE DESIGN OF LOW-POWER ... RESISTIVE SENSORS Ramon Casanella

... resolution to 0.15 ºC. We also observed a reduced output voltage with respect to that when R1 = 100 k This reduction can be attributed to the op amp input offset voltage (about -0.5 mV), which added perceptibly to the reduced output of the voltage divider (which was about 5 mV for the R1 selected) ...
High Efficiency NPC Multilevel Converters using Super
High Efficiency NPC Multilevel Converters using Super

... drive signals with under-lapping are applied in each case. Transient stages during under-lap intervals are shown in grey. Some observations are made with respect to Tables 1 and 2: 1. D5 and D6 are taken as being purpose-designed fastrecovery pn silicon or SiC Schottky diodes. The reverse recovery c ...
Owner`s Manual
Owner`s Manual

... and components, which draw more power (over 1800 watts) than your home was designed to support. Your home theater system is power hungry, too, which causes even more voltage sags and ultimately compromised home theater performance. Voltage swells (above the standard RMS value of 120 volts) are often ...
AVR2038: AT86RF231 Range Extension 8
AVR2038: AT86RF231 Range Extension 8

... A schematic of the RCB can be found in Appendix A.1 - Schematic. ...
Document
Document

Lecture 37
Lecture 37

Analysis on the Commutation Process of the Single
Analysis on the Commutation Process of the Single

... Usually pulse wave number, the more output in dc side is smooth, the closer the sine wave ac current. In order to increase the number of pulse wave, can increase the communication phase number, but the general increase in the number, the more is less time for each phase of electricity, such meetings ...
WT Series & PZ Power Analyzer WT series & PZ WT3000 WT500
WT Series & PZ Power Analyzer WT series & PZ WT3000 WT500

... ҂: Not supported (not a function of the WT main unit) 1 : An RS-232 and USB port (PC) cannot both be installed on a single WT main unit. 2 : RS-232 and ...
HIGH STEP–UP DC––DC CONVERTER FOR AC PHOTOVOLTAIC
HIGH STEP–UP DC––DC CONVERTER FOR AC PHOTOVOLTAIC

... Photo-voltaic power generation is becoming commercial success across worldwide. So that a high step-up BOOST converter is essential to step up the low voltage from photo-voltaic panel to high voltage as required by the applications (load or grid). Researchers are round the clock to develop better BO ...
Introduction to Switched-Mode Power Supply (SMPS) Circuits
Introduction to Switched-Mode Power Supply (SMPS) Circuits

Rajasthan Technical University, Kota  COURSE - FILE
Rajasthan Technical University, Kota COURSE - FILE

... 1. A transmission line of inductance 0.1 H and resistance 5 short circuited at t = 0, at the far end of a transmission line and is supplied by an ac t+150πsource of voltage v = 100 sin (100 ). Write the expression for the short circuit current, i(t). Find the approximate value of the first current m ...
Evaluates:  MAX8677A MAX8677A Evaluation Kit General Description Features
Evaluates: MAX8677A MAX8677A Evaluation Kit General Description Features

... The input and charge current limits are set, as shown in Table 2. It is often preferable to change the input current limit as the input power source is changed. The MAX8677A facilitates this by allowing different input current limits for DC and USB inputs. When the input current limit is reached, th ...
SRAM Voltage Stacking - University of California, Santa Cruz
SRAM Voltage Stacking - University of California, Santa Cruz

power quality guidebook
power quality guidebook

... tracking filtration for low energy noise and surge protection for high energy transients. These products continuously track the input AC power line and respond instantly upon detecting extraneous high frequency noise and high voltage transients caused by everyday events such as turning on machinery, ...
1 - Electrical and Computer Engineering
1 - Electrical and Computer Engineering

... frequency, DC to DC resonant converter. The goal of the design is to produce an extremely efficient, small, light weight, and cost effective DC to DC converter. These are some of the properties that are made possible by using a ZVT resonant type converter. The converter built in this project has 4 m ...
RF3229 QUAD-BAND GMSK TXM, 2 RX AND 3 UMTS SWITCH PORTS Features
RF3229 QUAD-BAND GMSK TXM, 2 RX AND 3 UMTS SWITCH PORTS Features

... achieve simple and efficient phone calibration in production. Additional Features Current Limiter During normal use, a mobile phone antenna will be subjected to a variety of conditions that can affect its designed resonant frequency. This shift in frequency appears as a varying impedance to a power ...
< 1 ... 72 73 74 75 76 77 78 79 80 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report