• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Remote Power Modules
Remote Power Modules

... Lutron® patented filter circuit technology compensates for incoming line-voltage variations, such as changes in RMS (Root Mean Square) voltage, frequency shifts, harmonics, and line noise. RTISS-TETM: Real-Time Illumination Stability System, Trailing Edge. Same as RTISS, but operates on the trailing ...
Aalborg Universitet High-Performance Control of Paralleled Three-Phase Inverters for Residential
Aalborg Universitet High-Performance Control of Paralleled Three-Phase Inverters for Residential

... (CAN bus), a central controller is used to derive compensated voltage references, which will be used by local controller, and exchange with DC/AC modules. This paper is organized as follows. Section II discusses the UPS topologies that are being used and presents the proposed control structure. In o ...
BA22313321
BA22313321

... Inductors are generally simulated with electro-magnetic (EM) simulators, which can compute the scattering (S-) parameters of the structure [16]. From the S-parameters of the EM-simulated inductor, we can calculate the admittance (Y-) parameters, from which the general PI network can be derived. Seve ...
Synchronous Voltage Source Inverter Using FCMLI
Synchronous Voltage Source Inverter Using FCMLI

... its voltage to supply the required reactive power, the midpoint terminal voltage returns to its specified value. It can be seen that the midpoint terminal voltage does not change much for a small disturbance occurred at 1.0 second but it has a large fluctuation for very large transient at 1.5 second ...
Power Supply Measurement and Analysis
Power Supply Measurement and Analysis

... the operating input voltage and the topology of the switchmode converters. A typical DC power supply designed for computing equipment operates on universal utility voltage ranging from 80 Vrms to 264 Vrms. At maximum input voltage, the OFF state voltage across the switching device (between TP1 and T ...
Power Conditioners Product Guide
Power Conditioners Product Guide

Medical Power Conditioning Presentation
Medical Power Conditioning Presentation

A Modular Power Electronics Instructional Laboratory
A Modular Power Electronics Instructional Laboratory

... two-switch forward converters. Two boxes used in synchronous fashion can operate full-bridge forward converters. A single box also supports dc-ac converters such as voltage sourced and half-bridge PWM inverters. Two boxes together support full-bridge inverters and even ac-ac converters. The ratings ...
In this section, we look at a wind power plant
In this section, we look at a wind power plant

This article appeared in a journal published by Elsevier. The... copy is furnished to the author for internal non-commercial research
This article appeared in a journal published by Elsevier. The... copy is furnished to the author for internal non-commercial research

... Ultra-capacitors (UCs) offer significantly better energy densities than do conventional capacitors. They are also highly suitable for the bulk of the transient power demands during acceleration and braking processes since the charge/discharge time of an UC can vary in a wide range [8–10], which ensur ...
Bulletin 1606 Switched Mode Power Supplies 1606-XLE960DX-3N
Bulletin 1606 Switched Mode Power Supplies 1606-XLE960DX-3N

... competitive pricing with only a small compromise in the output voltage regulation, output ripple and hold-up time. Weighing just 1.4 kg, the device provides 960 watts of continuous output power and an additional 25% power reserve for dynamic loads. The light-weight design along with compact dimensio ...
HVDC Technology 1.Introduction The development of HVDC(High
HVDC Technology 1.Introduction The development of HVDC(High

A Three Phase Based Four Switch Inverter for Renewable Energy
A Three Phase Based Four Switch Inverter for Renewable Energy

A Single-phase-to-three-phase Power Converter with an Active
A Single-phase-to-three-phase Power Converter with an Active

Cyclapse Classic Troubleshooting
Cyclapse Classic Troubleshooting

... If the battery pack is mostly discharged, it might run for a while, then stop, charge up some more, take a few more pics, etc. You might check the voltage on the battery pack! If it's low, take it out of the housing, and use the AC charger included with the system to charge it up. It may take up to ...
Seven Steps to an Accurate Worst-Case Power Analysis Using Xilinx Power Estimator (XPE)
Seven Steps to an Accurate Worst-Case Power Analysis Using Xilinx Power Estimator (XPE)

... Step 1: Obtain the latest version of Xilinx Power Estimator for the selected target device. It is important to make sure you are using the latest version of the Xilinx Power Estimator (XPE) tool because power information is updated periodically to reflect the latest power modeling and characterizati ...
Measuring Power regulated by Zero Crossing SCR
Measuring Power regulated by Zero Crossing SCR

... crossing controllers are not intended for use with inductive loads such as motors. A zero crossing controller is either conducting with full voltage applied to the load or it is not conducting. On or Off. The variable time base circuit controls the proportion of ON time to OFF time. ...
Document
Document

Implementation of Control Center Based Voltage and Var
Implementation of Control Center Based Voltage and Var

Improvement of Voltage Stability by the Advanced High Side Voltage
Improvement of Voltage Stability by the Advanced High Side Voltage

... control has been developed. This paper describes the principles, characteristics, and advantages of applying advanced HSVC in comparison with a conventional automatic voltage regulator (AVR) or a static var compensator. When applying the advanced HSVC, a high side voltage of a step-up transformer ca ...
Power Electronics - Dr. Imtiaz Hussain
Power Electronics - Dr. Imtiaz Hussain

... level to another, by storing the input energy temporarily and then releasing that energy to the output at a different voltage. • This conversion method is more power efficient (often 75% to 98%) than linear voltage regulation (which dissipates unwanted power as heat). • This efficiency is beneficial ...
MT-FD 6 - Newmar
MT-FD 6 - Newmar

... directly to the vehicle battery. Each of the 6 circuits are individually fused (ATO /ATC type) and wired to power-on/fuse fail indicator LED’s which simplifies circuit troubleshooting. The 6 distribution circuits are configured into 3 load groups of two, power control to each individually group is p ...
MAX2235 +3.6V, 1W Autoramping Power Amplifier for 900MHz Applications General Description
MAX2235 +3.6V, 1W Autoramping Power Amplifier for 900MHz Applications General Description

... thus extending the operating life of the battery. At +30dBm output power, efficiency is typically 47%. An additional power-saving feature is a shutdown mode that typically reduces supply current below 1µA. ...
WC Alexander, “Universal power converter,” US Patent
WC Alexander, “Universal power converter,” US Patent

Stabilizing Control of DC/DC Buck Converters with Constant
Stabilizing Control of DC/DC Buck Converters with Constant

... a boost converter has a low-frequency pole in the controlto-output transfer function with the current loop closed. Due to this low-frequency pole, even a moderate integrator gain could push the closed-loop poles into the right hand making the system unstable. The effects of CPLs in an induction moto ...
< 1 ... 68 69 70 71 72 73 74 75 76 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report