• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
THREE PHASE CIRCUITS
THREE PHASE CIRCUITS

... 282.85 kVA and the reactive power  sin 200 kVAR.  The capacitor bank supplies 50 kVAR (absorbs  50 kVAR) so the net reactive  power absorbed  150 kVAR. For the combination of load and capacitors,  250 kVA, and the pf is  ⁄ 0.8 lagging.   Note. Here, we did the calculations on three phase quantities. ...
1206 Demonstrate knowledge of ac power and power factor
1206 Demonstrate knowledge of ac power and power factor

... A.c power terms are defined according to industry practice, and their symbols and units are stated. Range ...
Motion Sensing Light Teardown
Motion Sensing Light Teardown

... Positive Ground Neutral ...
Turning an MLA-2500B into a GS-35B HF RF Deck
Turning an MLA-2500B into a GS-35B HF RF Deck

... Turning an MLA-2500B into a GS-35B HF RF Deck by WB8WJU The remote Power supply is 0-5000 VDC @ 2 AMP, CCS. Running at 3500VDC no load, it pulls down to 300VDC under full load. Plate current is 600-700 mA and grid current runs about 200 mA with 100 watts drive. Idle grid current is 100 mA with a sin ...
Document
Document

... Generated harmonic current as a consequence of employing power electronics converter is known as an important power quality issue in distribution networks. From industry point of view complying with international standards is mandatory, how ever cost and efficiency are two other important features, ...
Solution - Qi Xuan
Solution - Qi Xuan

Power Factor Correction Most domestic loads (such
Power Factor Correction Most domestic loads (such

Presentation - ABCs of Power Conditioning (06
Presentation - ABCs of Power Conditioning (06

... • Complete loss of power for seconds to hours in duration • Usually the result of a power company failure although may have internal facility causes, too. ...
DN426 - 6-Channel SAR ADCs for Industrial
DN426 - 6-Channel SAR ADCs for Industrial

... channels. It operates from a single 3V supply and features six independent sample-and-hold amplifiers and a single ADC. The single ADC with multiple S/HAs enables excellent range match (1mV) between channels and channel-tochannel skew (200ps). The versatile LTC2351-14 is ideally suited for industrial ...
DC-Leistungsnetzgeräte mit Energie-Rückspeisung
DC-Leistungsnetzgeräte mit Energie-Rückspeisung

UPQC Technology Information Sheet
UPQC Technology Information Sheet

... A number of factors are influencing the power-conditioning segment across the grid. These include advanced automations, i.e. real‐ time control and monitoring; the addition of fast acting power conditioning apparatus; customer based reliability and power quality enhancement; and micro-grids for Outa ...
TRX Data Sheet
TRX Data Sheet

... Typical applications include door retaining magnets, electromagnetic door closers or analogue system interface modules. ...
Shunt reactive power compensation
Shunt reactive power compensation

Power electronics basics
Power electronics basics

RB-1590 - HTGuide.com
RB-1590 - HTGuide.com

... considered and each component has been rigorously selected after extensive listening sessions. The circuit topography has been laid out in a true monoblock design ensuring maximum signal separation and improved stereo imaging. ...
CVM-C10 - Circutor
CVM-C10 - Circutor

... The CVM-C10 is a panel mounted (96 x 96 mm) power analyzer that records energy values. Compact and versatile, with 4-quadrant measurement (consumption and generation). Suitable for Medium or Low voltage installations, in both 3 or 4-wire three-phase circuits, two-phase circuits with or without neutr ...
POWER FACTOR CORRECTION
POWER FACTOR CORRECTION

... The cost of a power station is not just the cost of the coal and water it consumes in its lifetime though. There are the capital and associated costs of the machines themselves. An easy way to recover these costs is as an overhead charge or levy on the energy charges, and this is quite common. Anoth ...
High Voltage Power Supplies
High Voltage Power Supplies

... Rantec offers an extensive line of standard off-the-shelf CRT high voltage power supplies, which can also be tailored to specific requirements for applications ranging from medical imaging to aerospace to full military products. The Rantec Power Team’s exceptional technical expertise specializes in ...
ULTRA SLIMPAK II WV905 ®
ULTRA SLIMPAK II WV905 ®

... Overcurrent Shutdown with Automatic Restart UL, CSA & CE ...
the transformerless single-phase universal active power filter for
the transformerless single-phase universal active power filter for

Assiut university researches Harmonic Mitigation, Maximum Power
Assiut university researches Harmonic Mitigation, Maximum Power

LT2940 - True Analog Power and Current
LT2940 - True Analog Power and Current

latch_up - WordPress.com
latch_up - WordPress.com

Cisco PWR-C45-1000AC= power supply unit (PWR
Cisco PWR-C45-1000AC= power supply unit (PWR

... The Cisco Catalyst 4500 Series offers a variety of power supplies and accessories to meet the diverse needs of enterprise and service provider customers. All available Cisco Catalyst 4500 Series power supplies can be used for data-only deployments, which typically require just a few hundred watts. F ...
AC_Circuits2
AC_Circuits2

... opposition to current flow will be minimum and only limited by the ohmic resistance in the circuit Also, as tan   ...
< 1 ... 238 239 240 241 242 243 244 245 246 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report