• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Document
Document

FEATURING - SAF OPAL STARTERS
FEATURING - SAF OPAL STARTERS

... · Closed loop current regulation provides consistent torque, independent of the line voltage. · Direct power connections to the OP-STOP’s input and output terminals eliminate the need for power contactors. · Suitable for all input voltages from 200 VAC to 600 VAC, 50/60Hz (No adjustment necessary). ...
Power Management for Embedded Systems
Power Management for Embedded Systems

... An example of Power Supply for Embedded Platform ...
Document
Document

Info Letter No. 22 Definitions "Power factor" and "current
Info Letter No. 22 Definitions "Power factor" and "current

... power. In alternating and three-phase systems, the distortion power factor is produced by non-linear consumers such as rectifiers, inverters or magnetic components with saturation phenomena. The non-sinusoidal current can be represented as a sum of harmonic currents. These current harmonics in combi ...
electrical mechanical energy system la30-010
electrical mechanical energy system la30-010

- Discuss the measurement of power in circuits
- Discuss the measurement of power in circuits

... dryers, have special outlets for higher voltages). What typical currents do most household appliances operate at? Current varies but not TOO high - more than A total will trip most circuit breakers. Some devices, like cell phone chargers and electronics (especially computers) can be damaged by more ...
SYN-921 Single Voltage Power Supply
SYN-921 Single Voltage Power Supply

Font : Eurostile Extended Size : 14 Style : Bold Align
Font : Eurostile Extended Size : 14 Style : Bold Align

... equipment. 7th fuse holder has been provided in the unit to carry the spare fuse handy for any last minute use. Manual change over switch (heavy-duty toggle switch) has been provided to select any of the two power supply units in circuit. In the event of failure of one power supply unit, facility fo ...
Datasheet - UNIPOWER
Datasheet - UNIPOWER

... panel control connector J4. Three additional jacks (J5A, J5B and J5c) are provided for interface to external source modules. J-4 is a 25 Pin D connector while each of the J-5 connectors is a 9Pin D type. Certain commands or signal are operative in both modes. For example, the local HV OFF/RESET push ...
| PeRfeCT BalanCe WiTH 100 % ReDunDanCy
| PeRfeCT BalanCe WiTH 100 % ReDunDanCy

Electrical and Electronics Engineering Department
Electrical and Electronics Engineering Department

DC Motors - Anne Arundel Community College
DC Motors - Anne Arundel Community College

... (wires, transformers, generators) which cost more. ...
Course - IPFW.edu
Course - IPFW.edu

Power Supplies
Power Supplies

... negative charge towards it in a direct flow. Power supplies Generally come with a switch to change it from running from 110v(united states) to 240v (UK voltage.) Power supplies are rated in Watts, the more higher current devices you run the higher the watts need to be. ...
Power - BC Learning Network
Power - BC Learning Network

CT-CATVPS60/90 CATV Power Supply 60/90VAC, 15A
CT-CATVPS60/90 CATV Power Supply 60/90VAC, 15A

... • 5/8” female output connection • Durable LED indicator Description: The CableTronix CT-CATVPS60/90 is a CATV power supply designed to provide conditioned power to remote active devices over a hardline CATV cable distribution plant. This unit is designed to work with either 120VAC or 220VAC input vo ...
Film capacitors - PowerFactor Correction - MMI7000
Film capacitors - PowerFactor Correction - MMI7000

... rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specificatio ...
X-Ray Main Disconnect Panel - Bevco Imaging Suite Controls
X-Ray Main Disconnect Panel - Bevco Imaging Suite Controls

... manually reset the panel following a power failure.  This option  automatically restores power to the equipment following a power  loss.  The system incorporates a brief delay before re‐energizing to  allow for the incoming power to stabilize, reducing the potential  for damage to sensitive electron ...
PORTAWATTZ 600 inverter
PORTAWATTZ 600 inverter

... Designed for operating many household electrical products, as well as light commercial applications, the PORTAWATTZ™ 600 is an affordable, mid-range power inverter. It converts DC battery power into 115-volt AC power—up to 600 watts continuous—and is ideal for running large screen TVs, 5A power dril ...
Senior Power Electronics Engineer
Senior Power Electronics Engineer

Volume 4, Issue 4, Apr 2013 Editorial
Volume 4, Issue 4, Apr 2013 Editorial

... system-on-chips (SoC) in communication and computing has shifted the focus from traditional constraints (such as area, performance, cost, and reliability) to power consumption. Just as important, though not so obvious, is the need to reduce power consumption for non-portable systems, such as base st ...
Name MEASURING AND USING ELECTRICITY from the series
Name MEASURING AND USING ELECTRICITY from the series

... A kilowatt is used to measure large amounts of electrical power. A kilowatt is equal to 1,000 watts, so the hair dryer uses 1,200 watts or 1.2 kilowatts of power. Directions: Try these problems using the information and formula from the top part of this sheet. (Give your answers in watts or kilowatt ...
SOLIVIA Gateway M1 G2 Installation and operation manual The
SOLIVIA Gateway M1 G2 Installation and operation manual The

vp-12124 24 volt dc switching power supply
vp-12124 24 volt dc switching power supply

< 1 ... 236 237 238 239 240 241 242 243 244 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.