• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
3 Phase Power
3 Phase Power

Design Description a..
Design Description a..

... that line. The Stellaris® LM3S9B96 Development Kit contains both a microcontroller to control the system and a workable touch-screen user interface. The microcontroller will communicate with the TLK 100 Ethernet Transceiver in order to receive information from the Ethernet line. The TLK 100 has the ...
500-775 HCMU Datasheet.indd
500-775 HCMU Datasheet.indd

... POWER MANAGEMENT_ ...
Choosing a power supply
Choosing a power supply

PF Penalty - radio works rf consulting
PF Penalty - radio works rf consulting

... the existing infrastructure  Keeps utility costs down ...
Homework 9 [Solutions]
Homework 9 [Solutions]

... (P6.46) Two magnetically coupled coils have self-inductances of 60 mH and 9.6 mH, respectively. The mutual inductance between the coils is 22.8 mH. a. What is the coefficient of coupling? b. For these two coils, what is the largest value that M can have? c. Assume that the physical structure of thes ...
PMG Excitation
PMG Excitation

... If power factor is 1.0, then “x” amperes represents “y” power. At power factors below 1.0, power is less than the amperes indicate. ...
EASI™ Accessories - DVP412/432 tib v2
EASI™ Accessories - DVP412/432 tib v2

... EASI™ ACCESSORIES - DVP412 & 432 POWER SUPPLY UNITS The DVP units are power supplies for the EASI™ rack installations. They use primary switch mode technology thus providing a wide input voltage range, high efficiency and reliability. All units are short circuit and over temperature protected. ...
AN1108: Applying Power MOSFET Drivers
AN1108: Applying Power MOSFET Drivers

... 3. Inductive kick-back from the output load. ...
Implementation of Thyristor Switched Capacitors for Power Factor
Implementation of Thyristor Switched Capacitors for Power Factor

... loading the system with capacitors wipes out them. The lower the power factor, the worse the situation becomes from the supply authorities’ viewpoint. Accordingly, consumers are encouraged to improve their load power factor and in many cases are penalized if they do not. Improving the power factor m ...
Document
Document

Advanced VLSI Design - WSU EECS
Advanced VLSI Design - WSU EECS

Passive Bandpass and Notch Filters
Passive Bandpass and Notch Filters

Passive Bandpass and Notch Filters
Passive Bandpass and Notch Filters

... • For a nonideal voltage source, which is composed of a ideal voltage source (or Thévenin source) and Thévenin impedance, the maximum power to the load is obtained when the load impedance is equal to the Thévenin impedance. – For audio systems, the Thévenin impedance is designed to be 8W. – For most ...
MEGA Electronics Inc. Duratech industries AgileSwitch LEM USA
MEGA Electronics Inc. Duratech industries AgileSwitch LEM USA

... Solar Inverters Wind Turbines Motor Controllers HEV/EV Traction UPS ...
Connect Power Supplies in Series or Parallel
Connect Power Supplies in Series or Parallel

Document
Document

Power Supply HSD 9000 Series - Hima
Power Supply HSD 9000 Series - Hima

... The 19" power supply rack is designed to be installed as a direct replacement for obsolete PMP3 style racks and maintains the same connection references as the previous system. This ensures a straightforward upgrade with little modification of existing wiring or schematic drawings. ...
IXYS Introduces New 800V Optically Isolated AC
IXYS Introduces New 800V Optically Isolated AC

... subsidiary of IXYS Corporation (NASDAQ: IXYS), announced the availability of the CPC1964B, an AC Solid State Switch utilizing dual power SCR outputs. This device also includes zero-cross turn-on circuitry and is specified with a blocking voltage of 800Vp. In addition, the tightly controlled zero-cro ...
HigH Voltage poweR SUpply pS4012 foR pockelS cell DRiVeRS
HigH Voltage poweR SUpply pS4012 foR pockelS cell DRiVeRS

TRANSFORMERS
TRANSFORMERS

... Transformers are devices that are able to change the size of the _______ and consequently the size of the ______ of __.C. electricity. They are able to do this by using the __________ Currents to create changing ______ fields in the iron core at the centre of a coil of wire that has a known number o ...
GFC SERIES Low ProFileTM 400 Hz AND 28 VDC
GFC SERIES Low ProFileTM 400 Hz AND 28 VDC

... and development of reliable solid-state power systems. Through an innovative design, advanced self-diagnostic systems (BITE) and modular construction, Unitron products assure maximum power availability and minimal repair time. The Low ProFileTM Series includes 400 Hz and 28 VDC converters designed t ...
Assignment 3 - UniMAP Portal
Assignment 3 - UniMAP Portal

... balanced three-phase generator with a line voltage of 220 V. Determine the line current and the complex power absorbed by the load. ...
Energy Meter with Integrated Sense Resistor
Energy Meter with Integrated Sense Resistor

Case Study 1: RTC/Microcontroller Power Back
Case Study 1: RTC/Microcontroller Power Back

< 1 ... 234 235 236 237 238 239 240 241 242 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report