• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Model HVPS-Series HV Power Supplies
Model HVPS-Series HV Power Supplies

... High Voltage Power Supplies for Electronic Drivers Listed in Table 1 below is a list and specification of high voltage power supplies specifically designed to operate electronic drivers, such as those produced by Quantum Technology, Inc. These high voltage supplies produce low ripple, well regulated ...
Document
Document

PM150 SERIES
PM150 SERIES

... 1ms prior to V1 output dropping 5% below its nominal value. This signal also provides a minimum delay of 100 ms after V1 is within regulation. ...
revelite al technical spec sheet
revelite al technical spec sheet

... Based on power consumption, you may choose from a variety of power supply options. If you wish to power multiple Revelite AL fixtures with a single power supply, make sure the sum of the power drawn by each fixture does not exceed the maximum power rating for the particular power supply. Plug-in pow ...
Harmonic filters for high voltage - El
Harmonic filters for high voltage - El

Rack it. Power it. Cool it. Do it, with ONErack. - Comm-tec
Rack it. Power it. Cool it. Do it, with ONErack. - Comm-tec

... ONErack is a universal, powered mounting system that vastly improves rack installation of small devices. tvONE’s patent pending design converts randomly sized, externally-powered devices from any manufacturer into slide-in modules that can be installed quickly and cleanly and serviced easily. Chassi ...
of Abadan Oil Refining Co.Iran.
of Abadan Oil Refining Co.Iran.

POWER ELECTRONICS NOTES 10ES45
POWER ELECTRONICS NOTES 10ES45

... When CH1 is turned OFF, energy stored in inductance L forces current to flow through the diode D2 and the output voltage is zero. Current continues to flow in positive direction. When CH2 is triggered, the voltage E forces current to flow in opposite direction through L and CH2 . The output voltage ...
Solid – State VARIAC ® Replacement - hot
Solid – State VARIAC ® Replacement - hot

current - Courses
current - Courses

Experiment 1-3
Experiment 1-3

... measures the voltage drop across the diode, while the other monitors the current through the resistor and diode. By adjusting the output voltage of the power supply, measure the voltage across and current through the diode. As you vary the power supply voltage, monitor the power dissipated in the re ...
Primary Switch Mode Power Supply MINI-PS-120-230 AC
Primary Switch Mode Power Supply MINI-PS-120-230 AC

V NL - UiO
V NL - UiO

Basic Concepts_Circuit Elements
Basic Concepts_Circuit Elements

Power Semiconductor Devices
Power Semiconductor Devices

... For a time instant, there are 2 possible conduction states: – Each phase has a thyristor conducting. Load voltages are the same as the source voltages. – There are only 2 thyristors conducting, each from a phase. The load voltages of the two conducting phases are half of the corresponding line to li ...
STEVAL-ISA006V1
STEVAL-ISA006V1

... based on the VIPer12AS monolithic device and can be used to produce multiple non isolated positive or negative voltage outputs. ...
Report 5/4/07
Report 5/4/07

MiniPro - Telephone Switching International
MiniPro - Telephone Switching International

... Automatic Equalization: Automatic compensation for line loss between 0 dB and -36 dB at 772kHz Lightning Protection: Included 1010-01 3-element gas tube protector Secondary Lightning Protection: Diode resistor network withstands ± 2500 V / 2x10 ms Power Cross Protection: Meets UL 1459 Section 50A wh ...
DPPS - Defense Protected Power Systems, LLC
DPPS - Defense Protected Power Systems, LLC

... heat is the cause of significant system failure. By filtering the harmonics generated by the incoming power source as well as the harmonics generated by each individual system you are reducing the overall heat signature of each system utilizing DPPS ...
Analizzatore qualità di rete classe S, Cos FI, Wattmetro,registratore
Analizzatore qualità di rete classe S, Cos FI, Wattmetro,registratore

... • Flexible clamps (without additional power supply) are included in the Euro set. ...
Power Electronics
Power Electronics

... Nidec ASI is a global supplier of power electronic equipment and automation systems as well as electric motors and generators. This combination of technologies and background is the base of our expertise in engineering flexible, customized solutions for global industrial markets at competitive price ...
File
File

Dynamic Volt-Amp Reactive (D-VAR®) Compensation
Dynamic Volt-Amp Reactive (D-VAR®) Compensation

... Reactive) system is a powerful, cost-effective way to provide continuous voltage regulation, improve voltage stability, meet interconnection requirements and dynamically provide grid support where it’s needed. High-speed response to voltage disturbances D-VAR systems stabilize and regulate voltage a ...
Word Version - DCC - LIGO Document Control Center Portal
Word Version - DCC - LIGO Document Control Center Portal

PDF
PDF

... problems of nonlinear loads present in the system by static ac to dc converter (switched or non-switched), many proposals were made. The first proposal is to reduce converter ac input harmonic distortion level by preventing the load voltage from reversing [9]. This is achieved by a predetermined act ...
< 1 ... 208 209 210 211 212 213 214 215 216 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report