• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Sizing and purchasing a DEUTZ GENERATOR SET
Sizing and purchasing a DEUTZ GENERATOR SET

... outside. Mounting – Deutz generator sets should be mounted on a level base and use anti-vibration mounts when necessary. What is the difference between 3 phase and single-phase electricity? A phase is the factional part of the period of a sinusoidal wave, usually expressed in electrical degrees. A s ...
DC & VARIABLE-FREQUENCY AC WATT TRANSDUCER PC8- OSI
DC & VARIABLE-FREQUENCY AC WATT TRANSDUCER PC8- OSI

... Most units provide bidirectional output so that power consumption or generation can be measured. All units have input/output/case isolation. Standard units with input current ranges up to 2000 Amperes and voltage ranges to 600 Volts are available with outputs to interface with most data calibration ...
doc
doc

... FADC buffer positive supplies are currently sourced from a 5.5v intermediate voltage. There is one LDO (LT3080) per 8 dual buffer devices. These will now be connected directly to the external +7v linear power supply. The buffers have been changed to reduce the bandwidth and current consumption. Each ...
synchronous
synchronous

投影片 1
投影片 1

... relationship between line currents and phase currents in a ∆connected load. (a)The positive sequence. (b)The negative sequence. ...
Vacuum Contactors
Vacuum Contactors

... CLX: for motor starters up to 7.2 kV,offering front access to terminals with its slim line ● CBX: a cubic arrangement for 7.2 kV&12 kV applications ○ Single-phase or three-phase ○ Mechanical interlock between two contactors for motor reverse command A withdrawable type of CBX for motor starter cubli ...
E = Voltage / I = Amps /W = Watts / PF = Power Factor / Eff
E = Voltage / I = Amps /W = Watts / PF = Power Factor / Eff

... L = Length of conductor in feet I = Current in conductor (amperes) CM = Circular mil area of conductor ...
LED DimmingDriver - JLC-Tech
LED DimmingDriver - JLC-Tech

... E – Aluminum enclosure length, 290mm, refer to drawing for more details m = V – DC outputs Constant voltage Dimming ( PWM over 200Hz ) m = C – Constant current dimming ...
CC 1800/2800/4000 - Peavey Commercial Audio
CC 1800/2800/4000 - Peavey Commercial Audio

... protection circuitry against output short circuits, DC voltage on outputs, thermal overload and load protection due to any form of amp failure. It will include impedance sensing circuitry, a RMS clip limiter and Autoramp signal control. The amplifier shall have a sensitivity of 1.32 / 1.7 / 1.88 vol ...
IS1954 How Much Electrical Power Do You Need?
IS1954 How Much Electrical Power Do You Need?

... regarding generator use or solar power. It is even important for simple house wiring. The important thing is to find the maximum current that may be needed. If you have more than one appliance in a circuit, it is important to find the power needed for all the appliances so damage will not occur if a ...
Power Supply Decoupling
Power Supply Decoupling

Low Power, 24 Channel, DMX512 Dimmer
Low Power, 24 Channel, DMX512 Dimmer

... None. Overloading of outputs can result in output failure. ...
Solaira SHP High Power Control - Mor Electric Heating Assoc., Inc.
Solaira SHP High Power Control - Mor Electric Heating Assoc., Inc.

... SOLAIRA SHP HIGH POWER CONTROLS are supplied WITHOUT enclosures. Most electrical supply companies offer competitively priced options to enclose Solaira SHP controller. Should a contractor or wholesaler require enclosures, please contact Solaira directly for cost and availability. SIZING CONSIDERATIO ...
BASE Power Overview 2016
BASE Power Overview 2016

Pixie II v5.1 40 m QRP xcvr Kit
Pixie II v5.1 40 m QRP xcvr Kit

... Note: LPF: I checked for 2nd and 3rd harmonics and they were easy to find within the shack. I believe that higher quality components in the LPF will reduce harmonic radiation. However, another ham in the same city could not hear the second harmonic (this is my spectrum analyzer equivalent test). So, ...
catelog and detailed specifications
catelog and detailed specifications

... Our 4kVA SRNDTI Series UPS & UPR’s are Power Factor Corrected (PFC) on the input to near unity. Therefore, when non-linear loads requiring apparent power are present, only real power is reflected on the input utility line, ensuring efficient use of electricity and preventing harmful load harmonics f ...
Integrated Power Conversion
Integrated Power Conversion

... of inductor or transformer other than the electric field of the capacitors. It’s possible classifying the converter on the basis of  type source and load  AC-AC  AC-DC Rectifier  DC-AC Inverter ...
Sorensen XBT 32-3FTP 15–32 V 3–5 A 222 W
Sorensen XBT 32-3FTP 15–32 V 3–5 A 222 W

... there is one 0-32V/0-6A output and one 0-15V/0-5A/30W output; in series mode, there is one 0-64V/0-3A output and one 0-15V/0-5A/30W output. Safety of devices under test is paramount. The XBT series of power supplies provides superior device protection. Each output is fully isolated with voltage/curr ...
Real Time Simulation for Time-Varying Harmonic Distortion Analysis
Real Time Simulation for Time-Varying Harmonic Distortion Analysis

Regulated Power Supply.doc
Regulated Power Supply.doc

General Problem Statement
General Problem Statement

Power and Temperature
Power and Temperature

Grid measurement module - Bachmann electronic GmbH
Grid measurement module - Bachmann electronic GmbH

... sequences can be exported as CSV or COMTRADE file formats. The integrated simulation monitoring functions simplifies the configuration of protection and monitoring functions. Features: • Measurement of current, voltage, frequency, power, power factor, phase angle • Direct connection to input voltage ...
Mark SMITH - SIECI 2004 - Politechnika Wrocławska
Mark SMITH - SIECI 2004 - Politechnika Wrocławska

... Small, distributed generation (DG) technologies such as micro-turbines, photovoltaic and fuel cells are gaining wide interest because of rapid advances in technologies. The deployment of these generation units on distribution networks could potentially lower the cost of power delivery by placing ene ...
SHE–PWM CASCADED SEVENLEVEL INVERTER WITH
SHE–PWM CASCADED SEVENLEVEL INVERTER WITH

< 1 ... 207 208 209 210 211 212 213 214 215 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report