• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Raising the Efficiency of Power‐Factor Correction, from
Raising the Efficiency of Power‐Factor Correction, from

... elements to be physically small and lightweight, and helps improve efficiency compared to a passive circuit. With proper control of an active PFC stage, almost any complex load can be made to appear as a linear resistance, which significantly reduces the harmonic current content. ...
3 – The Power BJT 2
3 – The Power BJT 2

File
File

A Constant-current Source - BYU Physics and Astronomy
A Constant-current Source - BYU Physics and Astronomy

AN-9066  UniFET — Optimized Switch for Discontinuous Current
AN-9066 UniFET — Optimized Switch for Discontinuous Current

... It is obvious that the UniFET has far less energy loss than the super-junction device at high current condition. Also, the UniFET outperforms the super-junction device as gate resistance becomes larger. The only test point where the super-junction device does better than the UniFET is at the lowest ...
Harmonic Analysis of 230 V AC Power Supply
Harmonic Analysis of 230 V AC Power Supply

... Controlling and monitoring industrial system designs and their effects on utility distribution systems are a potential problem for the industrial consumer, who is responsible for complying with the IEEE 519-1992 recommended practices and procedures. Industrial facilities should include a system eval ...
1 or 2Ш – Linear AC Power Source
1 or 2Ш – Linear AC Power Source

... performance Linear AC Power Sources, the 105AMX offers the same low output voltage noise and distortion, ease of installation, and high AC waveform fidelity as found in all of Pacific Power’s Linear AC Power Sources. Control and operational features provide a high degree of versatility and ease of u ...
Prosine 1800.indd - Advantage Solar Wholesale Solar Dealer Supply
Prosine 1800.indd - Advantage Solar Wholesale Solar Dealer Supply

... Available in 12 and 24 volt models Models available with GFCI AC outlet or AC hardwire terminal strip for permanent installation into an electrical system (optional 15 A transfer switch available with hardwire option) Remote interface kit ...
PowerPoint 프레젠테이션
PowerPoint 프레젠테이션

Electronic_Circuits_Unit-7
Electronic_Circuits_Unit-7

A Frequency Controlled LCL - T Resonant Converter for H
A Frequency Controlled LCL - T Resonant Converter for H

4 l General information 12 l Single
4 l General information 12 l Single

/ Auxiliary power supply for peak power 1.
/ Auxiliary power supply for peak power 1.

... Average Power ...
A NOVEL HYBRID DSTATCOM TOPOLOGY FOR LOAD
A NOVEL HYBRID DSTATCOM TOPOLOGY FOR LOAD

... algorithms are available in literature to compute the reference compensator currents. However, due to simplicity in formulation and no confusion regarding the definition of powers, the control algorithm based on instantaneous symmetrical component theory is preferred. Based on algorithm, compensator ...
A NOVEL HYBRID DSTATCOM TOPOLOGY FOR LOAD
A NOVEL HYBRID DSTATCOM TOPOLOGY FOR LOAD

Powerpoint
Powerpoint

AC Machines 2 - Portal UniMAP
AC Machines 2 - Portal UniMAP

Loop and Nodal Analysis and Op Amps
Loop and Nodal Analysis and Op Amps

... For simulation set up select Transient and Fourier Analysis option, set start time, stop time and increment/step. These values must be selected to give you a clear plot in a reasonable amount of time. Do not enable Fourier. Use 50  in series with ideal source to simulate internal resistance of the ...
POA-5200
POA-5200

... capacitor customized for high sound quality, OFC wiring material, film capacitor and resistors, have all been subject to stringent listening tests during their selection process to ensure unfettered, high-grade sound reproduction. ...
Example - s3.amazonaws.com
Example - s3.amazonaws.com

Single and Three Phase AC or DC Power Testing Simplified
Single and Three Phase AC or DC Power Testing Simplified

... 5 - 300 VLN / 8.6 - 520 VLL DC Mode: 5 - 420Vdc ...
UPM310 - Isotron Systems
UPM310 - Isotron Systems

... UPM310 is a multifunction metering device suitable to measure the electrical parameters. It provides accurate True RMS measurements on bright LED display, or via serial communication port. The power meter replaces multiple existing analog meters as well as all single function meters or transducers. ...
112AMX AC Source, 1 Phase, 1200VA
112AMX AC Source, 1 Phase, 1200VA

... Linear AC Power Sources, the 112AMX offers the same low output voltage noise and distortion, ease of installation, and high AC waveform fidelity as found in all of Pacific Power’s Linear AC Power Sources. Control and operational features provide a high degree of versatility and ease of use for appli ...
42V High Power Density Buck Regulators in a Tiny QFN Package
42V High Power Density Buck Regulators in a Tiny QFN Package

... By Ying Cheng, Senior Applications Engineer, Power Products, Linear Technology Corp. ...
Automatic Power Factor Improvement by using
Automatic Power Factor Improvement by using

< 1 ... 190 191 192 193 194 195 196 197 198 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report