• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Demonstration of Using Flywheels and FACTS Control for Transient Stabilization and
Demonstration of Using Flywheels and FACTS Control for Transient Stabilization and

AE4301167171
AE4301167171

... 2001One of the important requirements in high voltage power applications is that harmonics be kept at some satisfactory level [6]. One way of reducing the level of harmonics presents in the converter output waveforms is to increase the number of converters [7], [8]. 2003The Voltage Source Converter ...
A 3D IC Designs Partitioning Algorithm with Power Consideration
A 3D IC Designs Partitioning Algorithm with Power Consideration

... • In order to supply power to every layer from the power/ground pads, which are located on the bottom layer, power TSVs are needed. – A power TSV is a TSV used only for transporting power. – There is a maximum power allowed for one power TSV. ...
In order to solve the problem of high voltage conversion
In order to solve the problem of high voltage conversion

EE442 FE Spr 98-99 - faraday - Eastern Mediterranean University
EE442 FE Spr 98-99 - faraday - Eastern Mediterranean University

... 4-) The three-phase half-bridge inverter shown below feeds a balanced Y-connected load , and is operated in the square-wave mode ( pole voltages are square waves ) at frequency f s . (a) Sketch the line-to-line voltage vab ( indicate all voltage levels ) and find its fundamental amplitude. (b) With ...
Datasheet CFS300 Series - Caltest Instruments GmbH
Datasheet CFS300 Series - Caltest Instruments GmbH

... 5 - 300 VLN / 8.6 - 520 VLL DC Mode: 5 - 420Vdc ...
total harmonic distortion analysis of front end current for diode
total harmonic distortion analysis of front end current for diode

... With the growing number of power electronic equipment and integration of it in the power system leads to poor and lagging input power factor. It also introduces increase of total harmonic distortion (THD) of the front end current. As for example, the three phase rectifier that has been used in many ...
POWER SUPPLIES
POWER SUPPLIES

... USEC/ISEC USEC/ISEC USEC/ISEC USEC/ISEC USEC/ISEC USEC/ISEC fn ...
L547B_M4300EX (Page 1)
L547B_M4300EX (Page 1)

... The M4300-EX is designed to provide noise isolation between 2 isolated outlet banks including 1 high current outlet so that any noise created by an A/V component can not contaminate the power going to equipment plugged into another outlet bank. ...
Improvement of Power Quality in Distribution System
Improvement of Power Quality in Distribution System

Uses for constant current power in Industrial Applications
Uses for constant current power in Industrial Applications

... Electron Beam Evaporation is a process that takes place in a vacuum chamber. The filament is heated by applying a DC voltage across its terminals and, when it has reached a suitable temperature, electron extraction is possible. Using an applied electric field, these electrons are accelerated from th ...
English  - Circuit Test Electronics
English - Circuit Test Electronics

Techniques for Measuring Efficiency
Techniques for Measuring Efficiency

... With the multimeter method, the effect of power factor is circumvented by taking the input power measurement after the diode rectifier stage has converted the AC input to DC. To improve the measurement accuracy, the losses in components prior to the DC bus stage must be taken into account. The diode ...


... An electric power system is a network of electrical components used to supply, transmit and use electric power. It is the network that supplies a region's homes and industry with power - for sizable regions, this power system is known as the grid and can be broadly divided into the generators that s ...
Depletion Mode MOSFET Technology
Depletion Mode MOSFET Technology

Class B, PA - Huji cse Moodle 2014/15
Class B, PA - Huji cse Moodle 2014/15

... In this example the power handling of a MOSFET with, Imax=1A and Vmax=10V is examined. Let’s assume Ron= 2 for all values of VGS and ro=∞ so that the transistor’s I-V characteristics can be ...
UNIT 5 PPT
UNIT 5 PPT

... change of phase thus the σ=0 ZL = 0; incident and reflected wave will be cancelled. Total refelection occurs ...
RF-LAMBDA
RF-LAMBDA

Shipboard Power Systems
Shipboard Power Systems

Active Bridge Rectifiers Reduce Heat Dissipation within PoE
Active Bridge Rectifiers Reduce Heat Dissipation within PoE

... of Figure 1. To quantify, the LT4320 combined with low channel resistance MOSFETs results in a 20mV drop across each ideal diode bridge MOSFET. This produces an input at the isolated supply of 8.96V (9V – 2 • 20mV). The higher input voltage drops the required input current to only 2.9A (26W/8.96V) v ...
Kit 47. 6-10 Watt Monophonic Power Amplifier
Kit 47. 6-10 Watt Monophonic Power Amplifier

... it 47 is a class AB audio power amplifier using a TDA2002 or TDA2003 module. These are replacements for the original LM383 which is no longer available. It is easy to construct and has a minimum of external components. The module has both short circuit protection and thermal protection. It can drive ...
AK4101210215
AK4101210215

QUASAR PROJECT KIT 3088 - 10W + 10W STEREO AMPLIFIER
QUASAR PROJECT KIT 3088 - 10W + 10W STEREO AMPLIFIER

... protection and thermal protection. This is the data book circuit which gives an excellent sound. The supply voltage required for this kit is 8 - 24V DC at 1 to 2 Amps. Maximum output power will only be obtained with a power supply of at least 20V and greater than 1.5 A, and using 4 ohm speakers. The ...
DN1001 - High Efficiency, High Density Power
DN1001 - High Efficiency, High Density Power

... the output voltage, adjustable soft start, a wide (4V to 32V) input voltage range, circuit protection features and two selectable light load operation modes—Stage SheddingTM mode and Burst Mode® operation to improve light load efficiency. 12-Phase, 1.5V/200A Supply Figure 1 shows the block diagram o ...
Power-monitoring units Power Meter Series 700
Power-monitoring units Power Meter Series 700

... (2) 15 user-configurable under and over conditions and in combination with digital inputs or outputs status. (3) 2 operation modes are available: normal or input demand synchronisation. (4) kWh and kVARh pulse output mode only. (5) 3 operation modes are available: external, alarm or kWh pulse output ...
< 1 ... 192 193 194 195 196 197 198 199 200 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report