• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
View - Shantilal Shah Engineering College,Bhavnagar
View - Shantilal Shah Engineering College,Bhavnagar

... Different types of triggering circuits for latching devices like SCR should be provided. Triggering circuits for voltage controlled devices with electrical isolation should be provided. Analogue as well as digital implementation of gate or base drive circuit should be demonstrated. Both triggering c ...
SurePower QL10513 13.0kW and 3.5kW, 13.56
SurePower QL10513 13.0kW and 3.5kW, 13.56

PUB-NP-006 Q. Tab 2.2: 2016 Additions Due to Load Growth Page 2
PUB-NP-006 Q. Tab 2.2: 2016 Additions Due to Load Growth Page 2

SCD Encapsulated - Sola/Hevi-Duty
SCD Encapsulated - Sola/Hevi-Duty

... SCD Series, Encapsulated, Industrial DC to DC Converter These compact, rugged DC to DC converters are power supplies designed to power industrial control instrumentation devices and equipment where AC power is not convenient or accessible. With high reliability and wide input range, these units can ...
Samlex SEC-1212/1223 Operating Manual
Samlex SEC-1212/1223 Operating Manual

... IMPORTANT SAFETY INSTRUCTIONS Please read before using your power supply. 1.) It Is recommended that you return your power supply to a qualified Samlex dealer for any service or repair. Incorrect assembly may result in electric shock or fire. 2.) To reduce the risk of electric shock, unplug power su ...
Installation Instructions
Installation Instructions

... to restart. Ground fault detection circuitry highly tolerant of capacitive leakage currents. Open Circuit Shutdown. Shuts down when opens are detected in the high voltage circuit. No “Jelly Beaning” or Mercury Migration. Maintains tubing current at 30 mA regardless of tube load or line voltage (if m ...
THREE–PHASE SYSTEMS 1. A balanced Y–connected source with
THREE–PHASE SYSTEMS 1. A balanced Y–connected source with

Wind Turbine Generators for Wind Power Plants
Wind Turbine Generators for Wind Power Plants

IXYS publish a new MOSFET brochure (Mar 2014) - H
IXYS publish a new MOSFET brochure (Mar 2014) - H

... The drain current of a depletion-mode Power MOSFET flows when its gate terminal is at zero volt, and hence the name ‘normally-on.’ A negative bias voltage is required to turn the device off, reducing the current to micro amperes. These devices, therefore, need only simple biasing schemes. And with a h ...
Low Power Design in VLSI
Low Power Design in VLSI

Power Factor
Power Factor

UPS Operating Modes: A Global Standard
UPS Operating Modes: A Global Standard

Using AC Sources for Compliance Testing
Using AC Sources for Compliance Testing

Power Electronics - Dr. Imtiaz Hussain
Power Electronics - Dr. Imtiaz Hussain

1760 Three-Phase Power Quality Recorder Topas
1760 Three-Phase Power Quality Recorder Topas

... power quality analysis and consistent compliance testing. Designed for analysis of utility and industrial power distribution systems, in medium and low-voltage networks, the Fluke 1760 provides the flexibility to customize thresholds, algorithms, and measurement selections. It has 8 input channels ( ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... operation while maintaining the operational parameters. Further increased openness in the power sector economy has put additional pressure on the power companies to manage the power system resources in the most optimum manner within regulatory constraints imposed by Regulator. It is the Load Dispatc ...
ATA1602_miniaturising the power circuit in
ATA1602_miniaturising the power circuit in

G42013438
G42013438

Design and Simulation of Boost Converter for Power Factor
Design and Simulation of Boost Converter for Power Factor

Flash FPGAs need only 1 mW of static power
Flash FPGAs need only 1 mW of static power

2.5.5 Preferred (Offsite) Power Supply System 1.0 Description
2.5.5 Preferred (Offsite) Power Supply System 1.0 Description

... Each EAT and associated power cables are sized to power the EPSS safety-related and non-safety-related loads. ...
Diris A40
Diris A40

Thevenin and Norton
Thevenin and Norton

101a-NK_Technologies_Power_Transducers
101a-NK_Technologies_Power_Transducers

... transformer is producing its maximum signal, the primary voltage is at the range maximum and power factor is at unity. For example, using the APT-480-5 A-120-420 with 400:5 current transformers, the transducer will produce 20 mA when there is 400 A through the CT and the primary voltage is 480. If t ...
360AMX AC Power Source Datasheet
360AMX AC Power Source Datasheet

... AC Power Sources, the 360AMX offers the same low output voltage noise and distortion, ease of installation, and high AC waveform fidelity as found in all of Pacific Power’s Linear AC Power Sources. Control and operational features provide a high degree of versatility and ease of use for applications ...
< 1 ... 186 187 188 189 190 191 192 193 194 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report