• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
DC25617623
DC25617623

... controller‖. The controller uses a hysteresis current controlled technique. Using such technique, the controller keeps the control system variable between boundaries of hysteresis area and gives correct switching signals for STATCOM operation. The control system scheme for generating the switching s ...
556 and 556H High Voltage Power Supply
556 and 556H High Voltage Power Supply

... precision potentiometer; output voltage is the sum of the 3 settings. METER Front-panel toggle switch selects display of output voltage in V or load current in mA. POLARITY Rear-panel switch selects either positive or negative output polarity. CONTROL Rear-panel locking toggle switch selects the ref ...
556 and 556H
556 and 556H

... precision potentiometer; output voltage is the sum of the 3 settings. METER Front-panel toggle switch selects display of output voltage in V or load current in mA. POLARITY Rear-panel switch selects either positive or negative output polarity. CONTROL Rear-panel locking toggle switch selects the ref ...
Presentation
Presentation

Experimental Evaluation of Matrix Converter for Wind Energy
Experimental Evaluation of Matrix Converter for Wind Energy

... which then becomes the main attraction for MC that has very high merit over back-to-back converter like free from commutation problems, improved voltage gain with simplified control, and extremely fast transient response [10]. Also, it provides the flexibility of more control levers for independent ...
Rockman Rockmodules
Rockman Rockmodules

... ‰ This basic rectifying and filtering circuit is not capable of providing the pure DC that we expect, and that would be represented by a horizontal, straight line. Moreover, the voltage of this smoothed DC (the height above the horizontal axis) would fluctuate and change, depending on the current de ...
Enhancement of Power Quality in Distribution System Using D
Enhancement of Power Quality in Distribution System Using D

talk - Electrical and Computer Engineering
talk - Electrical and Computer Engineering

Electrical Aspects of Electrical Generation from Tidal Currents
Electrical Aspects of Electrical Generation from Tidal Currents

... Loads will demand real power but will, in general, also demand reactive power. The latter has a significant impact on the voltage drops in the network, especially at high voltages. Thus it is not uncommon to have reactive loads that can be connected during periods of light load to hold the voltage a ...
V rms
V rms

... P = VI cos . The power factor angle, , is the phase angle difference between the voltage phasor and the current phasor, as determined by the equation,  = angle (V) – angle (I). In the case of a pure resistance, the voltage and current phasors are ‘in phase’ and thus  is zero degrees. Therefore, ...
Experiment 3
Experiment 3

... P = VI cos . The power factor angle, , is the phase angle difference between the voltage phasor and the current phasor, as determined by the equation,  = angle (V) – angle (I). In the case of a pure resistance, the voltage and current phasors are ‘in phase’ and thus  is zero degrees. Therefore, ...
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave

... card. Line interactive voltage regulation, network-grade surge suppression and long-lasting sine wave AC output during blackouts make this UPS ideal for advanced networking applications in datacenters, computer rooms and network closets. ...
IXAN0068 - IXYS Corporation
IXAN0068 - IXYS Corporation

... cannot be used when computing its thermal limitations in linear applications. For this case, one must use its SOA rating of 240W at VDS = 800V, ID = 0.3A and TC = 90oC. Assuming a 20% safety margin, this reduces its allowable power dissipation to 192W. The maximum output power for the power supply i ...
RT12-240V/2.4kW Rectifier Specification
RT12-240V/2.4kW Rectifier Specification

... The RT12-240V/2.4kW is a switched mode rectifier (SMR) module that delivers up to 2.4kW of output power (and up to 11A output current) into a 240V nominal DC system. The RT12 suits AC supply voltages between 208 and 240VAC but will also operate at reduced power from supplies as low as 100VAC. The RT ...
50 KW DGCA - West Generator Services
50 KW DGCA - West Generator Services

... Fuel Flow at Rated Load, US Gal/hr (L/hr) Maximum Inlet Restriction, in. Hg (mm Hg) Maximum Return Restriction, in. Hg (mm Hg) ...
What is the difference between power factor and ballast
What is the difference between power factor and ballast

... In its most technical form, power factor is how far a customer's electrical equipment causes the electric current delivered at the customer's site to be out of phase with the voltage. This phase difference can take two basics forms. 1) The current can “lag” the voltage when an inductive load (i.e., ...
here - Telephone Tribute
here - Telephone Tribute

... the second machine comes in. When the third machine is called in at the full load point of the second, the first one is sent to full load. While the controls described above are applied to charging motor generator sets, they also operate in a similar manner when rectifiers are involved which can be ...
Modular Power vs. Economies of Scale: Does the TCO live up to the
Modular Power vs. Economies of Scale: Does the TCO live up to the

... Last year, my co-presenter gave an excellent talk on modular data centers: actual project data for schedules and costs, plus examples of real-world pitfalls. What made Bill’s analysis manageable was the common denominator of all the modular data centers: the generic x86 server. Each modular data cen ...
2016 IEEE 16th International Conference on Environment and
2016 IEEE 16th International Conference on Environment and

... compatibility, SCADA, total harmonic distortion, renewable sources ...
HiTek Power Technical Datasheet
HiTek Power Technical Datasheet

... If more arcs occur they are counted to determine the arc rate; if this exceeds a safe level the power supply is shut down. The parameters are factory set. Safety: All materials used meet or exceed the requirements of UL94 V-1 for flammability. Meets the requirements of the Low Voltage Directive, 73/ ...
Electrical safety of LHC quench heater circuits in case of
Electrical safety of LHC quench heater circuits in case of

...  As expected fuse blows and protects the equipment  Maximum observed voltage: U_max = 22 V, t < 0.1 ms ...
Harnessing wasted energy in 4- to 20-mA current
Harnessing wasted energy in 4- to 20-mA current

Recent Developments on Micro-SMES System Project at the
Recent Developments on Micro-SMES System Project at the

... Bologna, begun in September 1997, is aimed to design and realize a 200 kJ/ 75 kW prototype. The project should be completed within the end of 2001. Two main subprojects are carried on: the former concerns the design of the SC (Superconducting Coil) and the cryogenic system. The latter is related to ...
P0470196100
P0470196100

... inverter, which usually operates, near the filter resonant frequency during starting process. The resonant filter is used to adapt the square waveform supplied by the inverter, attenuating the high-order harmonic components and supplying the lamp with sinusoidal waveforms [12]. A number of criteria ...
VIPer100 - Hobbielektronika.hu
VIPer100 - Hobbielektronika.hu

... Housed in the 5 pin TO-220, as well as in the PowerSO-10 surface mounting package, it offers maximum flexibility to designers allowing both primary or secondary regulation loop, despite using around 50% less components than a discrete solution. ...
< 1 ... 163 164 165 166 167 168 169 170 171 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report