• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Aalborg Universitet Compensation Devices in Microgrid
Aalborg Universitet Compensation Devices in Microgrid

this PDF file
this PDF file

EE501:Stochastic Processes
EE501:Stochastic Processes

... See office window ...
GUJARAT TECHNOLOGICAL UNIVERSITY  POWER ELECTRONICS (29) POWER CONVERTERS-I
GUJARAT TECHNOLOGICAL UNIVERSITY POWER ELECTRONICS (29) POWER CONVERTERS-I



... Objective: - To determine the efficiency and voltage regulation of a single phase transformer by load test. Apparatus Used: - One 1-Φ transformer, one 1-Φ auto-transformer, one voltmeters ammeters (0-10A), one wattmeter (0-10A, 0-300V), one 1-Φ load and connecting wires. ...
english - KEK Concept GmbH
english - KEK Concept GmbH

ee221_12
ee221_12

fundamentals of power systems
fundamentals of power systems

The development of power electronics in Europe
The development of power electronics in Europe

... Furthermore in the 1930s AC-AC frequency converters were designed and tested under real conditions. Such a converter is formed by coupling a rectifier and an inverter connected by a DC intermediate circuit. This allows to construct adjustable-speed drives with three phase induction motors. The speed ...
Efficiency and Other Benefits of 208 Volt Over 120 Volt Input
Efficiency and Other Benefits of 208 Volt Over 120 Volt Input

Technical Article
Technical Article

... the feedback loop is a fundamental component of the converter system, so it cannot be turned off completely. The trick, then, is to design the converter in such a way that internal blocks can be shut down when not needed, but turned on and made ready extremely fast when required. In fact, this mode ...
The Principles Of Dimming Leading edge dimming ? Triac
The Principles Of Dimming Leading edge dimming ? Triac

DCRK DIGITAL POWER FACTOR CONTROLLERS
DCRK DIGITAL POWER FACTOR CONTROLLERS

... When a plant is equipped with a co-generation system, it means there are conditions where energy is imported (consumed) and others where it is exported (generated). In these circumstances, the displacement angle between voltage and current can vary between 0° and 360° (four quadrants) so the DCRK mu ...
Volume 7, Issue 2, March-April, 2016, pp.59–68, Article ID: IJEET_07_02_007 http://
Volume 7, Issue 2, March-April, 2016, pp.59–68, Article ID: IJEET_07_02_007 http://

IJESRT
IJESRT

Design Solutions 8 - 2-Step Power Conversion: Portable Power for
Design Solutions 8 - 2-Step Power Conversion: Portable Power for

... with optimizing loop dynamics over widely varying battery and wall adapter voltages. ...
Technical specification for tender pm7-specifications-en
Technical specification for tender pm7-specifications-en

- Strathprints
- Strathprints

... increases in the power output of DG units are presented for the grid-connected and islanded mode of operation. The dynamic behaviour of the MG is investigated at the PCC (Bus-3). The positive sign in all waveforms of active and reactive power shows that the MG consumes power; while the negative sign ...
TekScope THS700 Series Handheld Digital Oscillscopes
TekScope THS700 Series Handheld Digital Oscillscopes

... glitches on a digital signal, a drop-out on a power line, an unstable clock in a communication network – all can be readily detected and analyzed. Video triggering allows triggering on all types of video signals from broadcast TV, video monitors, or high-resolution imaging systems. Both field and li ...
Keysight B1505A Power Device Analyzer/Curve Tracer 1500 A/10
Keysight B1505A Power Device Analyzer/Curve Tracer 1500 A/10

... High power wafer probing support enables testing at > 200 A and 10 kV on-wafer True knob-sweep curve tracer functionality Integrated thermocouple inputs for temperature measurement Oscilloscope view (I/V) function supports output waveform monitoring Fully automated measurement & data analysis High c ...
Fpix_upgrade_power - Indico
Fpix_upgrade_power - Indico

... • We will follow the same scheme as the barrel detector using DC-DC converters – Same power system for the whole pixel detector – Experience for the Phase 2 upgrade ...
Power Supply Features - Excelsys Technologies
Power Supply Features - Excelsys Technologies

... operated changes accordingly. By this we mean a change in ambient temperature, a change in line voltage and also a change in loading conditions. This is why setpoint accuracy is normally stated with the conditions also specified. 3.4 Ripple and Noise: Switching regulators generate noise during their ...
Principles of Conversion - Operating Tech Electronics, Inc.
Principles of Conversion - Operating Tech Electronics, Inc.

... These also are imported from Taiwan and offer exceptional value for money and excellent quality. Being fully boxed, they are easier to mount safely within an enclosure. The standard range covers 40 watts to 320 watts and one to four outputs. In addition, we can modify the products to customise them. ...
attachment=18223
attachment=18223

Technical Data: BUC Power Supplies
Technical Data: BUC Power Supplies

... on the antenna, the 7580 uses the same mounting brackets as the BUCs and weighs only 2.8 kg. It has Main and Auxiliary MS-type DC output connectors for externally-powered BUCs and accessories. ...
< 1 ... 167 168 169 170 171 172 173 174 175 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.