• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
View Paper - C.M. Technology
View Paper - C.M. Technology

... Load regulation of a FPS is provided by the use of a shunt magnetic path which has an air gap between it and the main EI lamination. The air gap is used to limit the flux in the shunt portion of the FPS and therefore preventing the magnetic saturation. In short it forms a "closed loop" whereby the f ...
ES Series specification sheet
ES Series specification sheet

... Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting ...
Efficient Architectures for Internal and External Computer
Efficient Architectures for Internal and External Computer

... The sum (Vramp + VRs) needs a shorter time to exceed Vref => The duty-cycle is smaller ...
POWER ELECTRONICS TECHNOLOGY
POWER ELECTRONICS TECHNOLOGY

Form B - PowerStream
Form B - PowerStream

... current at the point of connection of the generating units. The generated harmonic levels must not exceed those given in the CAN/CSA-C61000-3-6 Standards. No existing generators (if chosen, part a. is optional) a. Characteristics of Existing Generators (if applicable): ...
Comparison of Voltage Stability by Using Various Fact
Comparison of Voltage Stability by Using Various Fact

... The development of the modern system has led to an increasing complexity in the study of power systems, and also presents new challenges to power system stability, and in particular, to the aspects of transient stability and small-signal stability. So power system engineers are currently facing chal ...
Dynamic Performance of the Interline Unified Power Flow Controller
Dynamic Performance of the Interline Unified Power Flow Controller

current transformers
current transformers

... conductor around which it is put. The output signal from the current transformer is sent to the meter and the current flow in the primary circuit calculated. A current transformer is required for each phase. Polarity must be observed when fitting current transformers. If a current transformer is pla ...
AC Power Products Overview
AC Power Products Overview

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... Now more and more photovoltaic panels and wind turbines are integrated into grid, whose power fluctuation will lead to grid instability. Microgrid system is one of the solutions. There are many benefits of Microgrid including little pollution, higher reliability, better quality of power supply, and ...
4040
4040

... Figure 1: A passive PFC circuit requires only a few components to increase efficiency, but they are large due to operating at the line power frequency. ...
Thick Film Pulse Limitations
Thick Film Pulse Limitations

... level for flat chip resistors in pulse applications. For Pulse Power limitations of KOA thick film chip resistors, please refer to the graph, fig. 1. Power below that specified on the graph will, generally, not cause any significant degradation of the resistor, but note that the resistance value may ...


... The performance of the proposed concept of simultaneous load reactive power and voltage sag/swell compensation has been evaluated by simulation. To analyze the performance of UPQC-S, the source is assumed to be pure sinusoidal. Furthermore, for better visualization of results the load is considered ...
AN-1137 APPLICATION NOTE
AN-1137 APPLICATION NOTE

A Novel Control Strategy for Grid Connected Wind Turbines
A Novel Control Strategy for Grid Connected Wind Turbines

SX440 AUTOMATIC VOLTAGE REGULATOR (AVR)
SX440 AUTOMATIC VOLTAGE REGULATOR (AVR)

... In addition to regulating the generator voltage,the AVR circuitry includes under-speed and sensing loss protection features. Excitation power is derived directly from the generator terminals. Positive voltage build up from residual levels is ensured by the use of efficient semiconductors in the powe ...
Sorensen ASD Series 10–320 kW 40–60 Vdc 167–8000 Adc
Sorensen ASD Series 10–320 kW 40–60 Vdc 167–8000 Adc

... of: power, voltage, current, output impedance, output cable impedance and output cable voltage drop. The ASD allows you to program different “fault levels”, enabling detection of output cabling, connections or load problems before they cause critical system problems. The ASD can replace your PLC dev ...
Electronic Troubleshooting
Electronic Troubleshooting

... • Check all junction in both directions – High one way – other Low resistance • Double check all removed transistors – parallel ...
AM Audio PA-60X
AM Audio PA-60X

... More precisely, we saw “Class-A” power amplifiers reaching up to 100 watts and more while featuring quiescent currents of less than half ampere (when 100 watts would require theoretically 2.5 and practically at least 2 amperes). However, with AM Audio there is no need for any verification: their dev ...
DIN-Rail Power Supplies DIMENSION Products
DIN-Rail Power Supplies DIMENSION Products

... Power supplies in the Dimension X-Series include a new and innovative concept for generating a DC voltage from a three phase input. The X-Series is the ideal power supply for drive systems, DC motors, heaters and valves that do not require very high degree of regulation on the output voltage. These ...
International Electrical Engineering Journal (IEEJ) Vol. 5 (2014) No.12, pp. 1673-1679
International Electrical Engineering Journal (IEEJ) Vol. 5 (2014) No.12, pp. 1673-1679

... voltages into the grid at fundamental frequency and absorbs the active power from the grid at harmonic frequency. The 3rd harmonic is selected to exchange the active power between the converters through transmission line because it is a zero sequence harmonic that can easily blocked by the use of Υ- ...
Shunt Active Power Filter for Harmonic Mitigation by
Shunt Active Power Filter for Harmonic Mitigation by

... Now a day‟s power electronic based equipments are used in industrial and domestic purpose which have significant impacts on the quality of supplied voltage and have increased the harmonic current distortion on distribution systems. They have many negative effects on power system equipment and point ...
Noise Reduction Methods for Power Electronic
Noise Reduction Methods for Power Electronic

02 Linear Supplies
02 Linear Supplies

... reference voltage and ground, the output can be varied between 0 and the reference voltage multiplied by the gain of the circuit. There is a practical limit to this circuit, which is determined by the maximum voltage rating of the IC (40 volts). ...
FI36983988
FI36983988

< 1 ... 161 162 163 164 165 166 167 168 169 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report