• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
AN-556 Introduction to Power Supplies
AN-556 Introduction to Power Supplies

PXE Data Sheet
PXE Data Sheet

Lab #12 DC Power - Northern Arizona University
Lab #12 DC Power - Northern Arizona University

PSU_Part1_EfficiencyPowerFactor - Renesas e
PSU_Part1_EfficiencyPowerFactor - Renesas e

Very Compact and High Voltage Power Feeding
Very Compact and High Voltage Power Feeding

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,

to EEE B.Tech III Year-I Semester
to EEE B.Tech III Year-I Semester

... This course is an extension of power systems-I course. It deals with basic theory of transmission lines modeling and their performance analysis. Transient in power system, improvement of power factor and voltage control are discussed in detail. It is important for the student to understand the mecha ...
C48031522
C48031522

... series–shunt compensation, this paper proposes a single stage integrated nine-switch power conditioner, whose circuit connection is shown in Fig. 1(b). As its name roughly inferred, the proposed conditioner uses a nine-switch converter with two sets of output terminals, instead of the usual 12 switc ...
GZ2311941199
GZ2311941199

... centre’s to the load centres. In this process many things require investigation, such as the profile of the bus voltage, flow of active power (MW) and reactive power (MVar) in transmission lines, effect of rearranging circuits and installation of regulating devices etc., for different loading condit ...


... corona, output bus arcing or other common noise sources. The tests are typically performed semiannually and take about 30 minutes per generator. ...
RA60H1317M 数据资料DataSheet下载
RA60H1317M 数据资料DataSheet下载

... elements. In the application, which is base station applications and fixed station applications that operate with long term continuous transmission and a higher on-off frequency during transmitting, please consider the derating, the redundancy system, appropriate setting of the maintain period and o ...
2533 digital power meter - Advanced Test Equipment Rentals
2533 digital power meter - Advanced Test Equipment Rentals

... Suitable for accurate power measurement of distorted waveforms and inverters . _ Powerful computing functions include V (mean value of line or phase voltage), A (mean value of phase current), VA (apparent power), var (reactive power), and PF (power factor) . ...
(i) Transformer sub-stations.
(i) Transformer sub-stations.

... 6. Instrument transformers • The function of these instrument transformers is to transfer voltages or currents in the power lines to values which are convenient for the operation of measuring instruments and relays. (i) Current transformer (C.T.). • It is a step-up transformer which steps down the ...
Power supply of the
Power supply of the

... host not only elements of the power supply, but also elements of the voice alarming system (amplifiers, controllers, etc.). The power system takes care about supplying the mains (primary) power as well as the backup power of 24V or 48V from own battery banks. The battery banks are protected against ...
Category 5 Parallel Operating
Category 5 Parallel Operating

Category 4 Parallel Operating
Category 4 Parallel Operating

TEMPUS: VOLTAGE AND FREQUENCY DROOP CONTROL 1
TEMPUS: VOLTAGE AND FREQUENCY DROOP CONTROL 1

Static Voltage Stability Analysis of a Power System
Static Voltage Stability Analysis of a Power System

25471_energy_conversion_12..
25471_energy_conversion_12..

NI PXIe-1085 Modular Power Supply User Guide
NI PXIe-1085 Modular Power Supply User Guide

Transmitter
Transmitter

... For many, 2015 marked the ‘tipping point’ for wireless power with major announcements from several key smartphone and infrastructure providers. This paper explores the reasons behind the adoption of wireless power, after more than one hundred years in the wilderness, reviews some of the wireless pow ...
Tech Sheet - Alberta Governor Service
Tech Sheet - Alberta Governor Service

... functions and features for multiple application with up to 14 generators, each with a maximum individual rating of 16MW. Whether isolated or in parallel with the utility this device was designed for generators and switchgear equipment that require independent protection. The MFR 3 digitally measures ...
Document
Document

IOSR Journal of Electrical and Electronics Engineering PP 01-06 www.iosrjournals.org
IOSR Journal of Electrical and Electronics Engineering PP 01-06 www.iosrjournals.org

19000 Demonstrate advanced knowledge of electrical
19000 Demonstrate advanced knowledge of electrical

... Requirements for consent to assess and an outline of the moderation system that applies to this standard are outlined in the Consent and Moderation Requirements (CMR). The CMR also includes useful information about special requirements for organisations wishing to develop education and training prog ...
< 1 ... 129 130 131 132 133 134 135 136 137 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report