• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
The Impact of the Reactive Power Sharing Methods on Transmission
The Impact of the Reactive Power Sharing Methods on Transmission

... lines and integrates many renewable energy sources (RES). RESs are connected to microgrid by power converters, which allow to active and reactive power management. MG can work as support for traditional grid as well as stand-alone system for local loads. One of the topic issues in actual research is ...
AN1336
AN1336

... Inadvertent or unexpected loss of power can cause a number of system level problems. Memory loss, uncontrolled program status and indeterminate processor state are just a few of the issues which can occur during catastrophic power failure. Power-fail recovery is critical for applications created to ...
Power supply CP-D 12/2.1 Primary switch mode power supply Data sheet Features
Power supply CP-D 12/2.1 Primary switch mode power supply Data sheet Features

...  Do not modify the installation (primary and secondary side)! High current! Risk of electric arcs and electric shock (danger to life)!  Risk of burns: Depending on the operation conditions the enclosure can become very hot.  If the internal fuse blows, most probably the device is defect. In th ...
2016 China International Conference on Electricity Distribution
2016 China International Conference on Electricity Distribution

... When the irradiance changes from 800 W/m2 to 1000 W/m2, current amplitude changes from 46 A to 51 A and output power increases. When S=1000W/m2, t=25℃, we make the fast Fourier transform to A phase current of which the harmonic content is 63 and fundamental RMS is about 36.5A. As shown in Fig.11, cu ...
WECC PV PLant Power Flow Modeling Guidelines
WECC PV PLant Power Flow Modeling Guidelines

... voltage-squared effects. The WECC Data preparation Manual states that each switched capacitor should be modeled explicitly. Standard data includes nominal rating, impedance, and controlled device, if applicable. Operation of the shunt devices is coordinated with the plant-level reactive controller ( ...
ICT Modular Power Series_Data Sheet_800-340-000
ICT Modular Power Series_Data Sheet_800-340-000

... The ICT Modular Power Series provides N+1 redundancy with 700 watt hot swappable 12, 24 or 48 volt power modules. The power shelf can accomodate one to four power modules and one or two accessory modules. A dedicated slot holds the optional Intelligent Control Module for full TCP/IP remote monitorin ...
Wind Power Plant Dynamic Reactive Power
Wind Power Plant Dynamic Reactive Power

... Hybrid Reactive Power Dynamic Solutions • The combination of Statcom augmented by switched static reactive elements of capacitors and/or reactors • Provides fast-response, robust design that is dynamically capable integrated solutions to meet Voltage Support Services requirements • Uses Statcom “Ov ...
Flat Coil Planar Transformers
Flat Coil Planar Transformers

Description Installation Units Definition of the Output Data
Description Installation Units Definition of the Output Data

... Power Limitation A series power limitation function protects the device against overload. It is set to the values in the data sheet. If this value is exceeded, the system limits to maximum value and the output voltage is reduced depending on the magnitude of the overload. The device reverts automati ...
Harmonic Injection Technique to Reduce Harmonic
Harmonic Injection Technique to Reduce Harmonic

ALS Storage Ring RF System Upgrade
ALS Storage Ring RF System Upgrade

Keysight E363xA Series Programmable DC Power Supplies
Keysight E363xA Series Programmable DC Power Supplies

Ch07
Ch07

... rating of a surge suppressor needs to be checked before purchasing one • Surge suppressors with modem protection are also available ...
Harmonics (continued)
Harmonics (continued)

AVR120-6 - ElectricalManuals.net
AVR120-6 - ElectricalManuals.net

... seconds. This may be accomplished by stopping the prime mover or by interrupting the regulator power input with a reset switch. STABILITY ADJUST An internal screwdriver adjustable potentiometer provides adjustment to the response rate of the generator output voltage to a change in load. For normal o ...
Brochure Loadbank
Brochure Loadbank

... no large downpayments or interest costs and preserves your borrowing capacity, thus improving cash flow. With Aggreko rental solutions, all risks of equipment ownership, including servicing and repairs, lie with us. ...
Agilent E3631A Power Supply
Agilent E3631A Power Supply

... Affordable programmable power supplies to meet your needs The E363xA-series of programmable dc power supplies give you the performance of system power supplies without the high price. All models give you clean power, dependable regulation and fast transient response with built-in GPIB and RS-232 int ...
Experiment 2 - Single Phase Transformer
Experiment 2 - Single Phase Transformer

Power engineering, also called power systems engineering, is a
Power engineering, also called power systems engineering, is a

Agilent 363xA-Series Programmable dc Power Supplies Data Sheet
Agilent 363xA-Series Programmable dc Power Supplies Data Sheet

Overview - Yaskawa
Overview - Yaskawa

BDTIC www.BDTIC.com/infineon Special Report:
BDTIC www.BDTIC.com/infineon Special Report:

... Generally, IGBTs have high switching losses due to the current tail which limits the switching frequency operation. Active power factor correction (PFC) circuits are widely used as a front end to meet these standards. Most active PFC circuit designs use boost topology in Continuous Conduction Mode ( ...
AG4201218222
AG4201218222

Development of High Power CW and Pulsed RF Test Facility based
Development of High Power CW and Pulsed RF Test Facility based

AB34169175
AB34169175

... By making phase angle δ negative, power can be extracted from DC link. If the STATCOM becomes lesser than the extracted power, Pc in becomes negative and STATCOM starts to deliver active power to the source. During this transient state operation, Vd gradually decreases. The phasor diagrams which ill ...
< 1 ... 132 133 134 135 136 137 138 139 140 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report