
556 and 556H
... operation of photomultipliers, ionization chambers, semiconductor detectors, electron multipliers, and many other devices. The Model 556 is housed in a double-width NIM module (per DOE/ER0457T). The Model 556H is a standalone instrument designed for bench-top operation. The low-noise output is conti ...
... operation of photomultipliers, ionization chambers, semiconductor detectors, electron multipliers, and many other devices. The Model 556 is housed in a double-width NIM module (per DOE/ER0457T). The Model 556H is a standalone instrument designed for bench-top operation. The low-noise output is conti ...
Aalborg Universitet Hierarchical Controlled Grid-Connected Microgrid based on a Novel Autonomous
... power sharing performance and power supply quality in standalone operation, and then the tertiary control level is thereafter employed to perform the connection to the utility grid. By contrast, the control signal from secondary and tertiary control level will change the resonant frequency of the PR ...
... power sharing performance and power supply quality in standalone operation, and then the tertiary control level is thereafter employed to perform the connection to the utility grid. By contrast, the control signal from secondary and tertiary control level will change the resonant frequency of the PR ...
Gallium arsenide pseudo-current-mode logic
... signal processing. For example, the internal node in Fig. 1 is a low impedance node with correspondingly small voltage swing. This reduces the effect of voltage slewing there, suggesting the potential for high-speed performance. In addition, the circuit is built around a current mirror with the adva ...
... signal processing. For example, the internal node in Fig. 1 is a low impedance node with correspondingly small voltage swing. This reduces the effect of voltage slewing there, suggesting the potential for high-speed performance. In addition, the circuit is built around a current mirror with the adva ...
Water Pumping System with PLC and Frequency Control
... It can be noticed from Figure 11 and Figure 12 that the flow rate and pump speed in modeled system showed the capability for full control from zero to maximum for any required range of time in case of increasing or decreasing. 5. Discussion and Results PLC and frequency control of water pumping can ...
... It can be noticed from Figure 11 and Figure 12 that the flow rate and pump speed in modeled system showed the capability for full control from zero to maximum for any required range of time in case of increasing or decreasing. 5. Discussion and Results PLC and frequency control of water pumping can ...
DMP246 Dewpoint Transmitter for High Temperature Applications
... profiles, or removing them from the set, to eliminate too effective cooling that could increase the possibility of condensing water vapor. ...
... profiles, or removing them from the set, to eliminate too effective cooling that could increase the possibility of condensing water vapor. ...
Technical data, wiring diagram, dimensions (PDF - 485 kb)
... • The information on chemical resistance refers to laboratory tests with raw materials and finished products and to trials in the field in the areas of application indicated. • The materials used may be subjected to external influences (temperature, pressure, constructional fixture, effect of chem ...
... • The information on chemical resistance refers to laboratory tests with raw materials and finished products and to trials in the field in the areas of application indicated. • The materials used may be subjected to external influences (temperature, pressure, constructional fixture, effect of chem ...
How to drive DC motors with smart power ICs
... compares reference and feedback value for phase as well as frequency. In turn, of course, the AC tachogenerator must meet extreme requirements regarding phase stability since any jitter would be interpreted as a control error, producing a spurious response in the system. PLL speed control systems ar ...
... compares reference and feedback value for phase as well as frequency. In turn, of course, the AC tachogenerator must meet extreme requirements regarding phase stability since any jitter would be interpreted as a control error, producing a spurious response in the system. PLL speed control systems ar ...
a novel integrated power quality controller for microgrid
... integrated power quality controller (IPQC) suitable for microgrid is proposed, which can cater for the peculiar requirements of microgrid power quality, such as the harmonic high penetration, frequent voltage fluctuation and over current phenomenon, and bidirectional power flow and small capacity. F ...
... integrated power quality controller (IPQC) suitable for microgrid is proposed, which can cater for the peculiar requirements of microgrid power quality, such as the harmonic high penetration, frequent voltage fluctuation and over current phenomenon, and bidirectional power flow and small capacity. F ...
dual full-bridge pwm motor driver
... When the source driver is re-enabled, the winding current (the sense voltage) is again allowed to rise to the comparator’s threshold. This cycle repeats itself, maintaining the average motor winding current at the desired level. Loads with high distributed capaci-tances may result in high turn-ON cu ...
... When the source driver is re-enabled, the winding current (the sense voltage) is again allowed to rise to the comparator’s threshold. This cycle repeats itself, maintaining the average motor winding current at the desired level. Loads with high distributed capaci-tances may result in high turn-ON cu ...
Theory of Operations - University of Portland
... The VCO accepts the output voltage of the loop filter as its control voltage. The VCO will be set with a free running frequency of 90kHz so that it will operate at 90kHz with no control voltage. As the control voltage increases, the output frequency will increase towards 110kHz. The sweep range must ...
... The VCO accepts the output voltage of the loop filter as its control voltage. The VCO will be set with a free running frequency of 90kHz so that it will operate at 90kHz with no control voltage. As the control voltage increases, the output frequency will increase towards 110kHz. The sweep range must ...
Balanced Line Driver SSM2142
... The following data, taken from the THD test circuit on an Audio Precision System One using the internal 80 kHz noise filter, demonstrates the typical performance of a balanced pair system based on the SSM2142/SSM2141 chip set. Both differential and single-ended modes of operation are shown, under a ...
... The following data, taken from the THD test circuit on an Audio Precision System One using the internal 80 kHz noise filter, demonstrates the typical performance of a balanced pair system based on the SSM2142/SSM2141 chip set. Both differential and single-ended modes of operation are shown, under a ...
Response-Based, Feedforward Wide-Area Control
... PSS with noisy speed or frequency transducers and low gains. Power electronic devices, where justified, also offer powerful control performance (e.g., ref. 5). Further R&D is required for wide-area coordination of generator controls and transmission-level power electronic device controls ...
... PSS with noisy speed or frequency transducers and low gains. Power electronic devices, where justified, also offer powerful control performance (e.g., ref. 5). Further R&D is required for wide-area coordination of generator controls and transmission-level power electronic device controls ...
raise - lower (set-point) / ramp generator
... n Externally selectable ramp times n Output scaleable between max. & min. limits n Programmable response to simultaneous ...
... n Externally selectable ramp times n Output scaleable between max. & min. limits n Programmable response to simultaneous ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.