• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
op-amps
op-amps

... their ideal operation in noninverting configuration ...
SEL-487B
SEL-487B

... retrip, for each terminal. Internal breaker failure is determined by predefined protection schemes that allow different types of trip signals and current flow conditions. External breaker failure device inputs can be substituted for the internal breaker failure schemes, while providing individual or ...
D10R-Series - Vitecpower
D10R-Series - Vitecpower

ConfTNS-1c: Instructions for Authors of Papers Submitted for
ConfTNS-1c: Instructions for Authors of Papers Submitted for

... and convert bit commands which are delivered to the PS in the form of the PS Control Words. Since the firing angle is related to the voltage, these commands are, essentially, voltage commands. The voltage commands are derived either from closed loop proportional - integral (PI) current control again ...
Adjustable-Gain Difference Amplifier Circuit Measures Hundreds of
Adjustable-Gain Difference Amplifier Circuit Measures Hundreds of

... is less than or equal to 1, amplifier A1’s output will saturate first. With ±15-V supplies, the circuit can handle differential voltages up to 520 V p-p. Systems with ±10-V or ±5-V supply voltages can handle differential voltages up to 320 V p-p and 120 V p-p, respectively. With ratio R2/R1 greater ...
Bulletin 1413 Capacitor Bank Controller
Bulletin 1413 Capacitor Bank Controller

... The Capacitor Bank Control system consists of a MicroLogix™ 1400 controller, one or more PowerMonitor™ 1000s, a standard that is built-in the MicroLogix 1400 controller, and an optional Human-Machine Interface (HMI). Pre-engineered programming in the controller gathers real and reactive power data f ...
modular dc power supply model 62000b series
modular dc power supply model 62000b series

CL24579584
CL24579584

Universal Input, +/- 12 V Output 8 Watt PSU
Universal Input, +/- 12 V Output 8 Watt PSU

D1-BSX - Thermon
D1-BSX - Thermon

BP7A - L-Series IPM Interface Circuit Reference Design
BP7A - L-Series IPM Interface Circuit Reference Design

... control signals (UP,VP,WP,UN,VN,WN) are transferred from the system controller to the IPM using high speed optocoupled transistors (IC1-IC6). To maintain noise immunity, high speed optos generally require a film or ceramic decoupling capacitor connected near their VCC and GND pins (C1-C6). The IPM’s ...
Sliding Mode Control and Stability Analysis of a DC
Sliding Mode Control and Stability Analysis of a DC

... penalizes the second-stage DC-DC converter [1]. This DC-DC converter not only has to meet the characteristics demanded by the load, but also must process energy with high efficiency, high reliability, high power density and low cost [2]. In its simplest terms, the operation of a DC-DC converter can ...
Document
Document

S280-16-3 (Discontinued Product)
S280-16-3 (Discontinued Product)

360AMX AC Power Source Datasheet
360AMX AC Power Source Datasheet

... As a member of Pacific Power’s AMX-Series popular family of high performance Linear AC Power Sources, the 360AMX offers the same low output voltage noise and distortion, ease of installation, and high AC waveform fidelity as found in all of Pacific Power’s Linear AC Power Sources. Control and operat ...
Introduction PTC Thermistors
Introduction PTC Thermistors

... high positive temperature coefficient of resistance. They differ from Negative Temperature Coefficient (NTC) thermistors in the following manner: 1. The temperature coefficient of a PTC thermistor is positive only between certain temperatures. Outside this range, the temperature coefficient is eithe ...
Daylighting Controller Written Specification (word document)
Daylighting Controller Written Specification (word document)

PCS-9575 Static Frequency Converter
PCS-9575 Static Frequency Converter

Artificial Intelligence, Logic and Formalizing Common Sense
Artificial Intelligence, Logic and Formalizing Common Sense

... to this audience—why they shouldn’t avoid it. It gives a sense of the wider significance of the program that John presented in the 1989 paper, and it might help you to be persuasive when you talk to philosophers. I can use all the help I can get in convincing them to take work in AI seriously. McCar ...
SSM2142 数据手册DataSheet 下载
SSM2142 数据手册DataSheet 下载

34152.pdf
34152.pdf

... by providing supplemental damping to the oscillation of synchronous machine rotors through the generator excitation [2]. This damping is provided by an electric torque applied to the rotor that is in phase with the speed variation. Once the oscillations are damped, the thermal limits of the tie-line ...
• 100 - 240 Vac nominal input range • Overvoltage and short circuit
• 100 - 240 Vac nominal input range • Overvoltage and short circuit

... supply in a very small footprint. With the medical approvals the G2T60 is ideal for a variety of medical device applications including, small single board computers, battery charging, and running small motors, pumps, and solenoids. The series with full approval to EN60601-1 and EN60950-1 Standard, i ...
556 and 556H High Voltage Power Supply
556 and 556H High Voltage Power Supply

... operation of photomultipliers, ionization chambers, semiconductor detectors, electron multipliers, and many other devices. The Model 556 is housed in a double-width NIM module (per DOE/ER0457T). The Model 556H is a standalone instrument designed for bench-top operation. The low-noise output is conti ...
Real-time Software Design
Real-time Software Design

... Responsible for process management and resource (processor and memory) allocation. May be based on a standard kernel which is used unchanged or modified for a particular application. The kernel is the central component of most computer operating systems (OS). Its responsibilities include managing th ...
The Wein-Bridge Oscillator - Electrical and Computer Engineering
The Wein-Bridge Oscillator - Electrical and Computer Engineering

< 1 ... 416 417 418 419 420 421 422 423 424 ... 528 >

Control system



A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.