
LP2951
... can be used, but attention must be paid to the -20nA (typical) bias current required by the feedback pin. Using a 1.2M resistor for R2, this bias current will already cause a 2% shift in output voltage between full load and no load. Larger values of R2 exacerbate the problem. Using a 120k resistor ...
... can be used, but attention must be paid to the -20nA (typical) bias current required by the feedback pin. Using a 1.2M resistor for R2, this bias current will already cause a 2% shift in output voltage between full load and no load. Larger values of R2 exacerbate the problem. Using a 120k resistor ...
File
... Control of the vehicle is achieved by utilizing a master controller which receives feedback from a collection of sensors for decision making. Some applicable sensors may include a compass module for heading control and a thermal accelerometer for speed and stabilization control. The control system c ...
... Control of the vehicle is achieved by utilizing a master controller which receives feedback from a collection of sensors for decision making. Some applicable sensors may include a compass module for heading control and a thermal accelerometer for speed and stabilization control. The control system c ...
PDF format, 513k bytes
... differential pressures to 4 to 20mA DC signals with high accuracy. EDR-N8FD is suitable for measuring levels (water levels) and pressures of liquids in food process mainly using the sanitary silicon oil for the sealed liquid. Propylene glycol can be selected also depending on the application. ...
... differential pressures to 4 to 20mA DC signals with high accuracy. EDR-N8FD is suitable for measuring levels (water levels) and pressures of liquids in food process mainly using the sanitary silicon oil for the sealed liquid. Propylene glycol can be selected also depending on the application. ...
MSE Inside UP ZL/PL
... your sun shading system. The automatic or manual operation of the sun shading system when iced over as well as using the sun shading system during severe weather may cause damages and must be prevented by the user by ...
... your sun shading system. The automatic or manual operation of the sun shading system when iced over as well as using the sun shading system during severe weather may cause damages and must be prevented by the user by ...
Chlorolab 3 SyStem Chlorolab 3 SyStem
... The Oxylab control unit connects to the serial port of a Windows® PC either directly or using a HAN/USB adapter (for newer PC’s with no serial ports). The control unit features a built-in magnetic stirrer (for liquid-phase measurements) and all the electronics required to control and measure the si ...
... The Oxylab control unit connects to the serial port of a Windows® PC either directly or using a HAN/USB adapter (for newer PC’s with no serial ports). The control unit features a built-in magnetic stirrer (for liquid-phase measurements) and all the electronics required to control and measure the si ...
Chapter 0 - UniMAP Portal
... Propagation delay is the time for a change on an input of a gate to propagate to the output. Delay is usually measured at the 50% point with respect to the H and L output voltage levels. High-to-low (tPHL) and low-to-high (tPLH) output signal changes may have different propagation delays. High-to-lo ...
... Propagation delay is the time for a change on an input of a gate to propagate to the output. Delay is usually measured at the 50% point with respect to the H and L output voltage levels. High-to-low (tPHL) and low-to-high (tPLH) output signal changes may have different propagation delays. High-to-lo ...
ULTRA SLIMPAK G438-0001 ® Potentiometer Input Field
... The G438 is a DIN rail mount, potentiometer input signal conditioner with 1800VDC isolation between input, output and power. The input provides a constant voltage and is designed to accept any three-wire potentiometer from 100 Ohms to 100K Ohms. The field configurable output is switch selectable pro ...
... The G438 is a DIN rail mount, potentiometer input signal conditioner with 1800VDC isolation between input, output and power. The input provides a constant voltage and is designed to accept any three-wire potentiometer from 100 Ohms to 100K Ohms. The field configurable output is switch selectable pro ...
TA7804 Owner`s Manual Doc.indd
... switch, and then select the “L-PASS” (low pass) position on the L-PASS/H-PASS switch. Next, using “LPASS FREQ” you have control over what frequency you want your amp to start crossing over your signal. By turning this control all the way counter-clockwise you are crossing the signal over at 40Hz (th ...
... switch, and then select the “L-PASS” (low pass) position on the L-PASS/H-PASS switch. Next, using “LPASS FREQ” you have control over what frequency you want your amp to start crossing over your signal. By turning this control all the way counter-clockwise you are crossing the signal over at 40Hz (th ...
CLC730033 Evaluation Boards
... stage. With the gain adjust pin set at minimum gain (maximum attenuation), the output stage offset may be nulled independently from the input stage. R14 should be adjusted to yield the desired output error voltage (typically < 1 mV). Having corrected for the input offset voltage and bias current err ...
... stage. With the gain adjust pin set at minimum gain (maximum attenuation), the output stage offset may be nulled independently from the input stage. R14 should be adjusted to yield the desired output error voltage (typically < 1 mV). Having corrected for the input offset voltage and bias current err ...
cvrt users manual
... If the signal sent to the CVRT’s command input should become electrically open the control output will be forced to an off state when the 0-10V or 4-20mA inputs are selected. If the 135 Ω input becomes open the output will be full on. If the 05V/1-5V input becomes open the output state is typically ...
... If the signal sent to the CVRT’s command input should become electrically open the control output will be forced to an off state when the 0-10V or 4-20mA inputs are selected. If the 135 Ω input becomes open the output will be full on. If the 05V/1-5V input becomes open the output state is typically ...
Fuzzy Hysteresis Control and Parameter Optimization of a Shunt
... ramp comparison control methods (natural, asymmetrical or optimal PWM) associated with linear controllers, and the predicted current control [10, 11]. The first method is very simple and easy to implement, but has the disadvantage of an uncontrollable high switching frequency. This high frequency pl ...
... ramp comparison control methods (natural, asymmetrical or optimal PWM) associated with linear controllers, and the predicted current control [10, 11]. The first method is very simple and easy to implement, but has the disadvantage of an uncontrollable high switching frequency. This high frequency pl ...
Power Quality Conditioner with Series-Parallel
... converter acts as a non-sinusoidal voltage source, while the parallel converter acts as a non sinusoidal current source. A comparative analysis of the two operation modes is made, in which the advantages and disadvantages of each are discussed. Validation results are presented to confirm the theoret ...
... converter acts as a non-sinusoidal voltage source, while the parallel converter acts as a non sinusoidal current source. A comparative analysis of the two operation modes is made, in which the advantages and disadvantages of each are discussed. Validation results are presented to confirm the theoret ...
50a62-820 white-rodgers
... fan are energized and the ignition sequence will go into system lock out. The heat circulator and inducer will remain on as long as flame is detected. If flame is no longer detected, the inducer will turn off in 5 seconds and the circulator will turn off using the maximum heat off delay. 3. If, at a ...
... fan are energized and the ignition sequence will go into system lock out. The heat circulator and inducer will remain on as long as flame is detected. If flame is no longer detected, the inducer will turn off in 5 seconds and the circulator will turn off using the maximum heat off delay. 3. If, at a ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.