* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Chapter-6-complex
Valve RF amplifier wikipedia , lookup
Surge protector wikipedia , lookup
Standby power wikipedia , lookup
Power MOSFET wikipedia , lookup
Audio power wikipedia , lookup
Power electronics wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Captain Power and the Soldiers of the Future wikipedia , lookup
i (t )
v (t )
i (t ) I m cos(t i )
v (t ) V m cos(t v )
i (t ) I m cos(t )
v (t ) V m cos(t v i )
p (t ) v (t )i (t ) {V m cos(t v i )}{I m cos(t )}
V m I m cos(t v i ) cos(t )
Since
1
1
cos cos cos( ) cos( )
2
2
Therefore
p (t ) V m I m cos(v i ) V m I m cos(2t v i )
2
2
Since
cos( ) cos cos sin sin
cos(2t v i ) cos(v i )cos(2t ) sin(v i )sin(2t )
p (t ) V m I m cos(v i ) V m I m cos(v i )cos(2t ) V m I m sin(v i )sin(2t )
2
2
2
i (t )
v (t )
i (t ) I m cos(t )
v (t ) V m cos(t v i )
You can see that that the frequency of the Instantaneous
power is twice the frequency of the voltage or current
p (t ) V m I m cos(v i ) V m I m cos(v i ) cos(2t ) V m I m sin(v i ) sin(2t )
2
2
2
Q
P
p t P P cos(2t) Q sin(2t)
The instantaneous power
p t P P cos(2t) Q sin(2t)
P
VI
cos V I
2
real (or average) power (Watts)
Which is the actual power absorb by the element
Examples Electric Heater , Electric Stove , oven Toasters, Iron …etc
Q
VI
sin V I
2
reactive power
Which is the reactive power absorb or deliver by the element
Reactive power represents energy stored in reactive elements
(inductors and capacitors). Its unit is Volt Ampere Reactive (VAR)
The instantaneous power
p t P P cos(2t) Q sin(2t)
P
VI
cos V I
2
Q
VI
sin V I
2
real (or average) power (Watts)
reactive power (Volt Ampere Reactive (VAR) )
Complex Power
Previously, we found it convenient to introduce sinusoidal voltage and current in terms
of the complex number the phasor
Definition
Let the complex power be the complex sum of real power and reactive power
Pˆ P jQ
were
Pˆ is the complex power
P is the average power
Q is the reactive power
Advantages of using complex power
P̂ P jQ
We can compute the average and reactive power from the complex power S
P Real{Pˆ } VI cos(v i )
2
Q Ιmag{Pˆ } VI sin(v i )
2
complex power P̂ provide a geometric
interpretation
j
P̂ P jQ P̂ e
ˆ VA
|P|
Q
(reactive power) VAR
were
P̂ = P 2 Q 2
Is called apparent power (VA)
P
( average power) Watts
V I sin( )
sin( )
Q
v
v
i tan
i tan tan( )
tan
v i
P
V
I
cos(
)
cos(
)
v
v
i
i
=tan
v i
power factor angle
The geometric relations for a right triangle mean the four power triangle dimensions
( |P|
ˆ , P, Q, ) can be determined if any two of the four are known
Power Calculations
P̂ P jQ
V I cos(v i ) j V I sin(v i )
2
2
j (v i )
V
I
V
I
cos(v ) j sin(v )
e
i
i
2
2
were
I*
Is the conjugate of the current phasor
1 j (v ) j ( i ) 1V I*
Ve
Ie
2
2
I
I
V
Since
Similarly
1
Pˆ V I*
2
1
Pˆ V I*
2
Circuit
1
Pˆ VI *
2
1
1
1
Pˆ (Z I )I* ZII* Z I 2
2
2
2
*
2
1VV *
1 V
V
1
P̂ V
2 Z*
2 Z
2 Z*
Power Calculations Summery
I
V
ˆ VA
|P|
Pˆ P jQ
Circuit
V I cos(v i ) j V I sin(v i )
2
2
1
1
Pˆ VI * Z I
2
2
2
2
1 V
2 Z*
Q
(reactive power) VAR
P
( average power) Watts
P̂ P jQ P̂
P̂ = P 2 Q 2
e
j
Is called apparent power (VA)
v i
power factor angle
In any circuit, conservation of complex power is achieved
P̂
0
i
allcircuit elements
This implies that in any circuit, conservation of average power and
Conservation of reactive power are achieved
allcircuit elements Qi 0
allcircuit elements
Pi,AV 0
However, the apparent power (the magnitude of the complex power)
is not conserved
Ex:6.13 Determine the average and
reactive power delivered by the source.
10 30
The phasor current leaving the source is Î
1.86 98.2
2 j8 j3
The average power delivered by the source is:
1
*
PAV,source Re 10 30 1.86 98.2
2
1
Re 10 30 1.8698.2
2
9.28cos 30 98.2 3.45W
The reactive power delivered by the source is:
Qsource
1
Im 10 30 1.86 98.2 *
2
1
Im 10 30 1.8698.2
2
9.28sin 30 98.2 8.62 VAR
And the complex power delivered by the source is
P̂source PAV,source jQsource
3.45 j8.62VA
Determine the average power and reactive power delivered to each element
Î 1.86 98.2
The voltage across the elements are:
ˆ 2Iˆ 2(1.86 98.2 ) 3.71 98.2 V
V
R
ˆ j8Iˆ ( j8)(1.86 98.2 ) (890.0 )(1.86 98.2 )
V
L
14.86 8.2 V
ˆ j3Iˆ ( j3)(1.86 98.2 ) (3 90.0 )(1.86 98.2 )
V
C
5.57188.2 V
Thus the complex power delivered to each element is
1 ˆ ˆ
1
1
*
Pˆ R V
I
*
(3.71
98.2)(1.86
98.2
)
(3.71 98.2)(1.8698.2 )
R
2
2
2
3.450
3.45 j0 VA
1 ˆ ˆ
1
Pˆ L V
I
*
(14.86 8.2)(1.86 98.2 )* 13.7990 0 j13.79 VA
L
2
2
1 ˆ ˆ
1
0 j5.17 VA
PˆC V
I
*
(5.57 188.2)(1.86 98.2 )* 5.17 90
C
2
2
show that conservation of complex power, average
power, and reactive power is achieved.
Pˆsource
PˆR
PˆL
PˆC
3.45 j8.62 3.45 j0 0 j13.79 0 j5.17
PAV,source
3.45
Qsource
8.62
PAV,R PAV,L
3.45 0
QR QL
0 13.79
PAV,C
0
QC
5.17
6.6.1 Power Relations for the Resistor
The voltage and current are in phase so V I 0
Average power is:
PAV,R
1 VR2 1 2
IR R
2 R 2
Reactive power is zero for resistor
QR 0
6.6.1 Power Relations for the Inductor
ˆ jLIˆ L90 ˆI
V
L
L
L
The voltage leads the current by 90 so that
PAV,L
V I 90
1
VL I L cos 90 0
2
1
1
Q L VL I L sin 90 VL I L
2
2
6.6.1 Power Relations for the Capacitor
The current leads the voltage by 90 so that V I 90
ˆI jCV
ˆ C90 V
ˆ
C
C
C
ˆ 1 ˆI j 1 ˆI 1 90
V
C
C
C
jC
C
C
1
PAV,C VC IC cos 90 0
2
1
1
QC VC IC sin 90 VC IC
2
2
ˆ
IC
The power factor
Recall the Instantaneous power p(t)
p (t ) V m I m cos(v i ) V m I m cos(v i ) cos(2t ) V m I m sin(v i ) sin(2t )
2
2
2
P average
P average
Q reactive
power
power
power
P P cos(2t ) Q sin(2t )
The angle v i plays a role in the computation of both average and reactive power
The angle v i is referred to as the power factor angle
We now define the following :
The power factor
pf cos(v i )
The power factor
pf cos(v i )
Knowing the power factor pf does not tell you the power factor angle , because
cos(v i ) cos(i v )
To completely describe this angle, we use the descriptive phrases lagging power factor
and leading power factor
Lagging power factor implies that current lags voltage hence an inductive load
Leading power factor implies that current leads voltage hence a capacitive load
6.6.2 Power Factor
ˆP 1 VI
ˆ ˆ * PAV jQ
2
PAV
VI
cos V I
2
VI
Q
sin V I
2
pf cos V I
PAV
1
VI pf
2
0 pf 1
Since
V I 90
I I I
ˆ VA
|P|
Circuit
V V V
1
Pˆ VI *
2
1
ZII *
2
P
( average power) Watts
P jQ V I cos(v i ) j V I sin(v i )
2
2
*
V 2
1 V 1 VV *
1
V
2 Z 2 Z*
2 Z*
Q
(reactive power) VAR
1
Z| I |2
2
pf cos v i
I I I
I
+
V
ˆ VA
|P|
V V V
Circuit
P VI
V2
R
Q
(reactive power) VAR
P
( average power) Watts
2
V
1
1
1
Pˆ VI * P jQ V I cos(v i ) j V I sin(v i )
Z| I |2
2
2
2
2
2 Z*
IR
+
V
R
1
Pˆ V I * V R I R
R 2
R R
2
+
V
L
1
Pˆ V I * V LI L
L 2
L L
2
RI 2
IL
IC
+
V
C
1
Pˆ V I * V CI C
C 2
C C
2
1
RI R2
2
EX:6.15 Determine the average and reactive powers
delivered to the load impedance and the power factor
of the load
6.32 55.3 A
54.41 0.84 V
V̂L
ÎL
5 j9 j2
1000
4 j6 5 j9 j2
1000
4 j6 5 j9 j2
Average power
P
54.41 0.84 V
6.32 55.3
V
I
2
load load cos(v
A
i ) (54.41)(6.32) cos(0.84 55.3 ) 100 W
2
6.32 55.3 A
54.41 0.84 V
Average power
OR P
P
V
I
2
load load cos(v
i ) (54.41)(6.32) cos(0.84 55.3 ) 100 W
2
1 2
1 2
1
2
I R R Î L 5 6.32 5 100W
2
2
2
6.32 55.3 A
reactive powers
54.41 0.84 V
V̂L 54.41 0.84 V
Qload
V I
L L sin(v )
i
2
IˆL 6.32 55.3
A
(54.41)(6.32) sin(0.84 55.3 )
2
140 VAR
reactive powers
6.32 55.3 A
54.41 0.84 V
+
V
reactive
Qload
reactive
I
2
load load sin(v
Qload
OR
V
V
(j9 j2)
5(j9 j2)
V
i ) (54.41)(6.32) sin(0.84 55.3 )
2
I
I
reactive reactive
2
54.41 0.84
j7
5 j7
reactive
IˆL
54.41 0.84
I
140 VAR
| IˆL | 6.32
reactive
790
8.654.46
54.41 0.84 44.2734.7 V
EX:6.15 Determine the average and reactive powers
delivered to the load impedance and the power factor
of the load
+
V
reactive
44.2734.7
V̂load 54.41 0.84 V
IˆL 6.32 55.3
V I
L L sin(v )
140 VAR
i
2
V
I
reactive
reactive
I
| IˆL | 6.32
Qload
reactive
2
A
Qload
OR
Qload (44.27)(6.32) 139.89 140 VAR
2
V
reactive
44.27 V
V
This could also be calculated from the complex power
delivered to the load
ˆP 1 V
ˆ ˆI* 1 54.41 0.84
load
load load
2
2
100 j140VA
6.32 55.3
*
The power factor of the load is:
pf cos v I cos 0.84 55.3 0.581
The load is lagging because the current lags the voltage
A typical power distribution circuit
The consumer is charged for the average power consumed by the load
VI
VI
cos V I
pf
2
2
VI
The load requires a certain total apparent power
2
Ex 6.16 Suppose that the load
voltage figure is 170V
The line resistance is 0.1 ohm
The load requires 10KW of average power.
Examine the line losses for a load power factor of unity and for a power factor of 0.7 lagging.
The load current is obtained from
For unity power factor this is
For power factor of 0.7 I L
PAV 12 VL IL pf
2 10KW
IL
117.65A
170V 1
2 10KW
168.07A
170V 0.7
The powers consumed in the line losses
PAV,line
PAV,line
692.04W
1 2
I L R line
2
1412.33W
692.04W
1 2
I L R line
2
1412.33W
720 W extra power to be generated if pf is 0.7 to supply the load
unity pf
pf 0.7
unity pf
pf 0.7
Power Factor Correction
Ex: 6.17: in Ex 6.16 determine the value of capacitor across the load to correct
the power factor from 0.7 to unity if power frequency is 60Hz.
0.1
ˆ V 0o
V
S
S
+ ÎL
ˆ
Load
V
L
+
From Ex 6.16
ÎC
For power factor of 0.7
C
IL
I cos1 0.7 45.57
power factor 0.7 lagging
2 10KW
168.07A
170V
0.7
ÎL 168.07 45.57
ˆ
V
1700 jC 1700
The current through the added capacitor is: Î C L
ZC
1 jC
Hence the total current ˆI ˆI ˆI 168.07 45.57 jC 1700
line
L
C
117.66 j120.02 j 2 60 C 170
cos(v i ) 1
Unity power factor
v i 0
Imaginary component of the line current is zero
C
120.02
2 60 170
1873 uF
i v 0
j120.02 j 2 60 C 170 0
R
R TH
2
TH
ZL R TH jXTH
XTH XTH
2
2
R TH
XTH XTH
2
The average power delivered to the load is:
PAV ,load
1 2
V TH2 R L
V TH2 RTH
1
I RL 1
2
2 (RTH R L ) 2 (X TH X L ) 2 2 (RTH RTH )2 (X TH X TH )2
V TH2
1 V TH2 RTH
2 (2RTH ) 2 8RTH
6.6.3 Maximum Power Transfer
Source-load Configuration
Determine the load impedance so that maximum average power is delivered to
that load.
Represent the source and the load impedances with real and imaginary parts:
Zˆ R jX
S
S
S
Zˆ L R L jX L
The load current is:
IˆL
VˆS
VˆS
ˆ
ˆ
Z S Z L ( RS RL ) j ( X S X L )
The average power delivered to the load is:
PAV ,load
V S2 R L
1 ˆ 2
1
I L RL
2
2 (R S R L ) 2 (X S X L ) 2
Since the reactance can be negative and to max value, we choose X L X S
leaving
PAV ,load
1 V S2 R L
2 (R S R L ) 2
Differentiate with respect to RL and set to zero to determine required RL which is
RL= RS
Hence:
Zˆ L ZˆS*
In this case the load is matched to the source.
The max power delivered to the load becomes:
PAV ,load ,max
V S2
8R S
6.6.4 Superposition of Average Power
Average power computation when circuit contains more than one source
i ' (t ) I 1 sin(1t I 1 )
V s sin(1t 1 ) '
v (t ) V 1 sin(1t V 1 )
i '' (t ) I 2 sin(2t I 2 )
I s sin(2t 2 ) ''
v (t ) V 2 sin(2t V 2 )
i ' (t ) I 1 sin(1t I 1 )
V s sin(1t 1 ) '
v (t ) V 1 sin(1t V 1 )
i '' (t ) I 2 sin(2t I 2 )
I s sin(2t 2 ) ''
v (t ) V 2 sin(2t V 2 )
i ' (t ) I 1 sin(1t I 1 )
V s sin(1t 1 ) '
v (t ) V 1 sin(1t V 1 )
i '' (t ) I 2 sin(2t I 2 )
I s sin(2t 2 ) ''
v (t ) V 2 sin(2t V 2 )
The instantaneous power delivered to the element is
p (t ) v (t )i (t ) (v ' v '' )(i ' i '' ) (v 'i ' v ''i '' ) (v 'i '' v ''i ' )
Substituting
p (t ) [V 1 sin(1t V 1 )I 1 sin(1t I 1 ) V 2 sin(2t V 2 )I 2 sin(2t I 2 )]
[V 1 sin(1t V 1 )I 2 sin(2t I 2 ) V 2 sin(2t V 2 )I 1 sin(1t I 1 )]
1
1
sin A sin B cos(A B ) cos(A B )
Using the identity
p (t ) [V 1 sin(1t V 1 )I 1 sin(1t I 1 ) V 2 sin(2t V 2 )I 2 sin(2t I 2 )]
[V 1 sin(1t V 1 )I 2 sin(2t I 2 ) V 2 sin(2t V 2 )I 1 sin(1t I 1 )]
1
2
1
2
Using the identity sin A sin B cos(A B ) cos(A B )
p (t )
V 1I 1
V I
cos(V 1 I 1 ) 2 2 cos(V 2 I 2 )
2
2
PAV 1
PAV
2
V 1I 1
V I
cos(21t V 1 I 1 ) 2 2 cos(22t V 2 I 2 )
2
2
VI
VI
1 2 cos[(1 2 )t V 1 I 2 ] 1 2 cos[(1 2 )t V 1 I 2 ]
2
2
V I
V I
2 1 cos[(2 1 )t V 2 I 1 ] 2 1 cos[(2 1 )t V 2 I 1 ]
2
2
p (t )
V 1I 1
V I
cos(V 1 I 1 ) 2 2 cos(V 2 I 2 )
2
2
PAV 1
PAV
Average powers delivered individually by the sources
2
V 1I 1
V I
cos(21t V 1 I 1 ) 2 2 cos(22t V 2 I 2 )
2
2
VI
VI
1 2 cos[(1 2 )t V 1 I 2 ] 1 2 cos[(1 2 )t V 1 I 2 ]
2
2
V I
V I
2 1 cos[(2 1 )t V 2 I 1 ] 2 1 cos[(2 1 )t V 2 I 1 ]
2
2
Suppose that the two frequencies are integer multiples of some frequency
and
2 m
as 1 n
The instantaneous power becomes
p (t )
V 1I 1
V I
cos(V 1 I 1 ) 2 2 cos(V 2 I 2 )
2
2
PAV 1
PAV
2
V 1I 1
V I
cos(2nt V 1 I 1 ) 2 2 cos(2m t V 2 I 2 )
2
2
VI
VI
1 2 cos[(n m )t V 1 I 2 ] 1 2 cos[(n m )t V 1 I 2 ]
2
2
V I
V I
2 1 cos[(m n )t V 2 I 1 ] 2 1 cos[(m n )t V 2 I 1 ]
2
2
Averaging the instantaneous over the common period T 2 /
1 T
p (t )dt
0
T
PAV 1 PAV 2
V 1I 2
V 2I 1
P
P
cos(
)
cos(V 2 I 1 )
V1
I2
AV 1 AV 2
2
2
PAV
if n m
if n m
THUS: we may superimpose the average powers delivered by sources of
different frequencies, but we may not, in general, apply superposition to
average power if the sources are of the same frequency.
where
V 1I 1
1
cos(V 1 I 1 ) Re(Vˆ1Iˆ1* )
2
2
V I
1
2 2 cos(V 2 I 2 ) Re(Vˆ2 Iˆ2* )
2
2
PAV 1
PAV 2
Ex 6.18: Determine the average power delivered
by the two sources of the circuit
Iˆ'
1030
2.357 15
2 j 4 1 j 1
Hence the average power delivered by the voltage source is
'
AV
P
1
1
'
ˆ
Re(1030 I *) 10 2.357 cos(30 15 ) 8.333 W
2
2
This can be confirmed from average powers delivered to the two resistors
'
'
'
PAV
PAV
P
,2
AV ,1
1 ˆ' 2
1 ˆ' 2
I 2 I 1 8.333 W
2
2
By current division:
Iˆx''
1 j
2
3
3 60 0.589 154.33
2
2 j 6 1 j
3
2 j6
Iˆy''
3 60 3.101 49.08
2
2 j 6 1 j
3
''
The voltage across the current source is
Vˆ (2 j 6)Iˆx'' 3.727 82.77
Hence the average power delivered by the current source is
''
PAV
1
1
Re(Vˆ '' 360 ) 3.727 3 cos(82.77 60 ) 5.154 W
2
2
This may be again confirmed by computing the average power delivered to the
1 ˆ'' 2
1 ˆ'' 2
''
''
''
Two resistors:
PAV PAV ,2 PAV ,1 I x 2 I y 1 5.154 W
2
2
Since frequencies are not the same, total average power delivered is the sum
of average powers delivered individually by each source
EX 6.19: Determine the average power delivered
by the two sources
Since both sources have the same frequency, we can’t use superposition.
So we include both sources in one phasor circuit. The total average power
delivered by the sources is equal to the average power delivered to the resistor
We use superposition on the phasor circuit to find the current across the resistor
Iˆ'
100
3.536 45
2 j 4 j 2
Iˆ''
j2
5 60 3.536 15
2 j 4 j 2
Iˆ Iˆ' Iˆ'' 3.536 45 3.53615 6.831 30
Iˆ Iˆ' Iˆ'' 3.536 45 3.53615 6.831 30
The phasor current is:
Hence the average power delivered to the resistor is PAV
1 ˆ2
I 2 46.66 W
2
Note that we may not superimpose average powers delivered to the resistors by the
individual sources
1 ˆ' 2
1 ˆ '' 2
2
I
2
2
I
2 25 46.66
We can compute this total average power by directly computing the average power
delivered by the sources from the phasor circuit
The voltage across the current source is
Vˆ 100 (2 j 4)Iˆ 22.88 132.63
The average power delivered by voltage source is
PAV , voltage source
1
Re[(100 )Iˆ* ] 29.58 W
2
The average power delivered by the current source is
PAV , current source
1
Re[Vˆ (560 )] 17.08 W
2
The total average power delivered by the sources is
PAV , source 29.58 17.08 46.66 W
6.6.5 Effective (RMS) Values of Periodic Waveforms
Sinusoidal waveform is one of more general periodic waveforms
Apply a periodic current source with period T on resistor R
i (t ) i (t nT )
n 0,1, 2,3,...
The instantaneous power delivered to the resistor is
p (t ) i 2 (t )R
The average power delivered to the resistor is
PAV
1
T
T
0
1
i (t )R dt R
T
2
T
0
i 2 (t )dt
2
I eff
Hence the average power delivered to the resistor by this periodic waveform
can be viewed as equivalent to that produced by a DC waveform whose value is
I eff
1
T
T
0
i 2 (t )dt
This is called the effective value of the waveform or the root-mean-square
RMS value of the waveform
Ex 6.20 Determine the RMS value of the current
waveform and the average power this would
deliver to 3 resistor
The RMS value of the waveform is
I rms
1 1
4dt 1.155 A
0
3
Hence the average power delivered to the resistor is
2
PAV I rms
3 4 W
RMS voltages and currents in phasor circuits
The sinusoid x t X sin t has a RMS value of
X rms
1
T
T
0
[X sin(t )]2 dt
X
0.707X
2
Hence the average power delivered to a resistor by a sinusoidal voltage or current
2
1 V 2 V rms
1
waveform is
P
I 2R I 2 R
AV , R
2 R
R
rms
2
In general, the average power delivered to an element is
PAV
ˆ Iˆ*
1
V
*
Re(Vˆˆ
I *) Re
Re(Vˆrms Iˆrms )
2
2 2
Therefore, if sinusoidal voltages and currents are specified in their RMS values
rather than their peak values, the factor ½ is removed from all average-power
expressions. However, the time-domain expressions require a magnitude multiplied
by square root of 2 X sin(t ) 2X sin(t ) X sin(t )
rms
rms
Since X is the peak value of the waveform. Common household voltage are specified
as 120V. This is the RMS value of the peak of 170V.
Ex 6.21 Determine the average power delivered by
the source and the time-domain current i(t)
Phasor circuit with rms rather than peak
The phasor current is
7.0730
Iˆrms
1.25 15
4 j 4
Hence the average power delivered by the source is
1
*
PAV , source ReVˆrms Iˆrms
Re[(7.0730 )(1.2515 )] 6.25 W Re[(1030 ) (1.25 215 )]
2
None RMS
None RMS
The time-domain current is
i (t ) 2I rms cos(2t 15 ) 1.77cos(2t 15 ) A
Commercial Power Distribution
a
a
+
Van =Vp0
c
n
Vbn =Vp120
b
b
Vcn =Vp120
c
a
a
+
Van =Vp0
Van =Vp0
Vbn =Vp120
c
n
Vbn =Vp120
b
b
Vp
is rms value of the voltage
The peak is
2 Vp
Time domain representation
Vcn =Vp120
Vcn =Vp120
v an (t ) 2V p sin t V
c
v bn (t ) 2V p sin(t 120 ) V
v cn (t ) 2V p sin(t 120 ) V
a
a
Im
+
Van =Vp0
c
n
Vbn =Vp120
b
Van =Vp0
Re
b
Vcn =Vp120
Vcn =Vp120
Vbn =Vp120
c
Im
Vcn =Vp120
Van =Vp0
Van Vbn +Vcn= 0
Re
V p0 V p120 V p120 0
Vbn =Vp120
Im
Im
Im
Vcn
Van
Van
Van
Re
Re
Re
Vbn
Van Vbn
Van Vbn
Vbn
Vbn
a
a
+
+
Van =Vp0
Vbn =Vp120
b
c
n
b
Vab = Van Vnb = Van V
bn
V p0 V p120
Vcn =Vp120
3
1
2
2
0
1
V p cos(0 ) + j V p sin(0 ) V p cos(120 ) + j V p sin(120 )
3Vp
V 3
j p
2
2
3V p30
c
3 3 Vp
V 3
j p
2
2
3V p
3 j 1
2
2
Im
Using Vectors
Vcn =Vp120
Van =Vp0
Re
Vab = Van Vbn
Vbn =Vp120
Im
Vbn
Vab = Van Vbn
3V p
3V p30
Vbn
line voltage is 3 phase voltage
30
Vp
Re
Van
Im
Vab
Vcn
30
3V p30
Re
Van
Vbn
line voltage is 3 phase voltage
a
a
+
Van =Vp0
c
n
Vbn =Vp120
b
b
Vcn =Vp120
c
+
Vbc = Vbn Vnc
Vbc = Vbn Vnc = Vbn Vcn V p 120 V p120 3V p 90
Vca = Vcn Vna = Vcn Van
V p120 V p0
3V p150
Vca
3V p150
Im
Vab
Vcn
30
30
90
o
Re
Van
Vbn
Vbc
3V p30
3V p 90
6.9.1 Wye-Connected Loads
We are going to investigate the transmission of power from
three phase generator to two types of load:
I – WYE connected load
V p 0
ˆ
Ia
Zˆ L
V p 120
ˆ
Ib
Zˆ L
V p 120
ˆ
Ic
Zˆ L
ˆI Iˆ Iˆ Vp 0 Vp 120 Vp 120 0
a
b
c
Zˆ L
Hence the current returning through the neutral wire is zero,
and the neutral may be removed
Zˆ L Z L Z L
Power calculation
For a balanced wye-connected load, the voltages across the individual
loads are the respective phase voltages whether the neutral is connected
or not.
The power delivered to the individual loads is three times the power
delivered to an individual load, because the individual loads are identical.
PAV ,total
V p 0
*
ˆ
3Re(V p 0 I a ) 3Re V p 0
ˆ*
Z
L
V p2
cos Z L
3
ZL
No ½ factor in power expression because values are rms
PAV ,total 3Re(V p 0 Iˆa* )
V p 0
3Re V p 0
ˆ*
Z
L
V p2
3
cos Z L
ZL
Since the line voltage is more accessible than the phase voltage
Power in terms of line-to-line voltages and load current gives
PAV ,total
V p2
3
cos Z L 3V PV P cos 3 V P I L cos Z
ZL
L
ZL
Z
L
VL
3
I L cos Z L 3 V L I L cos Z L
3
Example 6.24
Consider a balanced, wye-connected load
where each load impedance is
Zˆ L 50 j50
the phase voltages are 120 V.
Determine the total average power delivered
to the load.
The line currents are
1200
Iˆa
1.7 45 A
50 j 50
120 120
Iˆb
1.7 165 A
50 j 50
120120
Iˆc
1.775 A
50 j 50
Hence, the average power delivered to each load is
PAV Re[(1200 )(1.745 )] 120 1.7 cos(45 ) 144 W
The total average power delivered to the load is
PAV , total 3 144 432 W
Example 6.25
If the line voltage of a balanced, wye-connected load is 208 V
and the total average power delivered to the load is 900 W,
determine each load if their power factors are 0.8 leading.
900 W 3 V L I L cos Z L
Thus
IL
900
3.12 A
3(208)(0.8)
The phase voltage is Vp
VL
120 V
3
Thus the magnitude of the individual load impedance is Z L
Vp
IL
38.43
Since the power factor is 0.8 leading (current leads voltage; voltage lags current)
Z cos1 0.8 36.87 .
L
Thus the individual loads are
Zˆ L 38.43 36.87
30.74 j 23.06
Example 6.25
If the line voltage of a balanced, wye-connected load is
208 V and the total average power delivered to the load
is 900 W, determine each load if their power factors are
0.8 leading.
900 W 3 V L I L cos Z L
Thus
IL
900
3.12 A
3(208)(0.8)
The phase voltage is
Vp
VL
120 V
3
Thus the magnitude of the individual load impedance is
ZL
Vp
IL
38.43
Since the power factor is 0.8 leading (current leads voltage; voltage lags current)
Z cos1 0.8 36.87 .
L
Thus the individual loads are
Zˆ L 38.43 36.87
30.74 j 23.06