* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Analog to Digital Conversion - AHEPL
Quantization (signal processing) wikipedia , lookup
Control system wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Dynamic range compression wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Buck converter wikipedia , lookup
Flip-flop (electronics) wikipedia , lookup
Oscilloscope wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Oscilloscope types wikipedia , lookup
Rectiverter wikipedia , lookup
Time-to-digital converter wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Integrating ADC wikipedia , lookup
Analog to Digital Conversion ADC Essentials A/D Conversion Techniques Interfacing the ADC to the IBM PC DAS (Data Acquisition Systems) How to select and use an ADC A low cost DAS for the IBM PC 1 Why ADC ?  Digital Signal Processing is more popular  Easy to implement, modify, …  Low cost   Data from real world are typically Analog Needs conversion system  from raw measurements to digital data  Consists of  Amplifier, Filters  Sample and Hold Circuit, Multiplexer  ADC Chap 0 2 ADC Essentials   Basic I/O Relationship  ADC is Rationing System  x = Analog input / Reference n bits ADC  Number of discrete output level : 2n  Quantum    LSB size Q = LSB = FS / 2n Quantization Error  1/2 LSB  Reduced by increasing n • Fraction: 0 ~ 1 Chap 0 3 Converter Errors  Offset Error  Integral Linearity Error  Gain Error  Differential Linearity Error Can be eliminated by initial adjustments  Nonlinear Error  Chap 0  Hard to remove 4 Terminologies   Chap 0 Converter Resolution  The smallest change required in the analog input of an ADC to change its output code by one level Converter Accuracy  The difference between the actual input voltage and the full-scale weighted equivalent of the binary output code  Maximum sum of all converter errors including quantization error   Conversion Time  Required time (tc) before the converter can provide valid output data Converter Throughput Rate  The number of times the input signal can be sampled maintaining full accuracy  Inverse of the total time required for one successful conversion  Inverse of Conversion time if No S/H(Sample and Hold) circuit is used 5 More on Conversion Time    Input voltage change during the conversion process introduces an undesirable uncertainty Full conversion accuracy is realized only if this uncertainty is kept low below the converter’s resolution Example  8-bit ADC  Conversion Time: 100sec  Sinusoidal input  vi  A sin(2 ft )  dvi  2 fA cos(2 ft )  2 fA dt  of Change x tc  resolution f   2A 2 n tc 1 2  tc n  12.4 Hz Limited to Low frequency of 12.4 Hz  Chap 0 Let FS = 2A 2 fA   Rate dV FS ( )  max  dt 2 n tc Rate of change Few Applications 6 S/H increase Performance  S/H (Sample and Hold)  Analog circuits that quickly samples the input signal on command and then holds it relatively constant while the ADC performs conversion  Aperture time (ta)  Chap 0 Time delay occurs in S/H circuits between the time the hold command is received and the instant the actual transition to the hold mode takes  Example  20 nsec aperture time   f  1 2  ta n  62.17 KHz Reasonably good for 100sec converter 7 Analog Input Signal  Typically, Differential or Single-ended input signal of a single polarity  Typical Input Range  0 ~ 10V and 0 ~ 5V Actual input signal does not span Full Input range  Matching input signal and input range  Prescaling input signal using OP Amp   If    Chap 0 Some of the converter output code never used Waste of converter dynamic range Greater relative effects of the converter errors on output  In a final stage of preconditioning circuit By proportionally scaling down the reference signal  If reference signal is adjustable 8 Converting bipolar to unipolar   Using unipolar converter when input signal is bipolar  Scaling down the input  Adding an offset  Input signal is scaled and an offset is added Add offset scaled Bipolar Converter  If polarity information in output is desired  Bipolar input range  Chap 0 Typically, 0 ~ 5V  Bipolar Output  2’s Complement  Offset Binary  Sign Magnitude 9 Outputs and Analog Reference Signal  I/O of typical ADC  Errors in reference signal  From  Initial Adjustment  Drift with time and temperature   Cause  Gain error in Transfer characteristics ADC output  Number of bits  8 and 12 bits are typical  10, 14, 16 bits also available  Typically natural binary Chap 0  BCD (3½ BCD) • For digital panel meter,  To realize full accuracy of ADC  Precise and stable reference is crucial  Typically, precision IC voltage reference is used • 5ppm/C ~ 100ppm/C 10 Control Signals   Start From CPU  Initiate the conversion process   HBE / LBE From CPU  To read Output word after EOC   • High Byte Enable BUSY / EOC To CPU  Conversion is in progress  HBE  LBE • Low Byte Enable 0=Busy: In progress  1=EOC: End of Conversion  Chap 0 11 A/D Conversion Techniques   Counter or Tracking ADC Successive Approximation ADC  Most    Dual Slop Integrating ADC Voltage to Frequency ADC Parallel or Flash ADC  Fast   Chap 0 Commonly Used Conversion Software Implementation Shaft Encoder 12 Counter Type ADC   Block diagram Operation  Reset and Start Counter  DAC convert Digital output of Counter to Analog signal  Compare Analog input and Output of DAC  Vi < VDAC • Continue counting   • Stop counting Waveform Digital Output = Output of Counter Disadvantage  Conversion time is varied    Chap 0 Vi = VDAC 2n Clock Period for Full Scale input 13 Tracking Type ADC  Tracking or Servo Type  Using Up/Down Counter to track input signal continuously  Chap 0  For slow varying input  Can be used as S/H circuit  By stopping desired instant  Digital Output  Long Hold Time Disabling UP (Down) control, Converter generate  Minimum (Maximum) value reached by input signal over a given period 14 Successive Approximation ADC    Chap 0 Most Commonly used in medium to high speed Converters Based on approximating the input signal with binary code and then successively revising this approximation until best approximation is achieved SAR(Successive Approximation Register) holds the current binary value  Block Diagram 15 Successive Approximation ADC  Circuit waveform  Conversion Time n clock for n-bit ADC  Fixed conversion time   Serial Output is easily generated   Chap 0 Logic Flow Bit decision are made in serial order 16 Dual Slope Integrating ADC   Operation T1  Integrate 0 vi dt  Reset and integrate  Thus T1vi ( AVG )  t2Vr t2   v  V i ( AVG ) r Applications T1  Chap 0   t2 0 Vr dt DPM(Digital Panel Meter), DMM(Digital Multimeter), …  Excellent Noise Rejection  High frequency noise cancelled out by integration  Proper T1 eliminates line noise  Easy to obtain good resolution Low Speed  If T1 = 60Hz, converter throughput rate < 30 samples/s 17 Voltage to Frequency ADC   VFC (Voltage to Frequency Converter)  Convert analog input voltage to train of pulses Counter  Generates Digital output by counting pulses over a fixed interval of time    Low Speed Good Noise Immunity High resolution For slow varying signal  With long conversion time   Applicable to remote data sensing in noisy environments  Chap 0 Digital transmission over a long distance 18 Parallel or Flash ADC    Chap 0 Very High speed conversion  Up to 100MHz for 8 bit resolution  Video, Radar, Digital Oscilloscope Single Step Conversion  2n –1 comparator  Precision Resistive Network  Encoder Resolution is limited  Large number of comparator in IC  Homework #5-1  어떻게 동시에 비교가 되는지를 설명하라. 19 Software Implementation  Implementation with software using microprocessor Counting  Shifting  Inverting  Code Conversion …  Chap 0  Limited Practical Use  Availability of Good performance with very reasonable Cost 20 Shaft Encoder    Chap 0 Elctromechanical ADC  Convert shaft angle to digital output Encoding  Optical or Magnetic Sensor Applications  Machine tools, Industrial robotics, Numerical control  Binary Encoder  Misalignment of mechanism causes large error   Ex: 011  111 (180deg) Gray Encoder  Misalignment causes 1 LSB error 21 Interfacing the ADC to the IBM PC  Interface Operations  Most-recent-data Scheme     At end of conversion it updates an output FIFO Automatically start new conversion CPU read FIFO to acquire most recent data  CPU initiate conversion every time it needs new data CPU check EOC until conversion is finished Using CPU Interrupt     Start-and-wait Scheme  Chap 0   CPU initiate conversion every time it needs new data CPU can proceed to do other thing ADC interrupt CPU when conversion is complete CPU goes to ISR See Chapter 3, For more information about 8259A 22 Interface Software   Memory Mapped Transfers  ADC is assigned in Memory Space   MRD, MWR signal MOV instruction More complex decoding logic I/O Mapped Transfers  ADC is in I/O Space      IOR, IOW signal IN, OUT instruction More Simple decoding logic  DMA (Direct Memory Access)  CPU release system bus by the request of DMA  DMA controller carried out data transfer by generating the required addresses and control signals  The system bus control reverts back to CPU when data transfer is finished DMA is useful  High Speed  High volume data transfer  Chap 0 Disk Drive interface 23 Interface Hardware  Parallel Data Format   Three state output buffer in ADC  To Interface ADC   CPU + Decoding logic • To generate Chip Select signal • To generate Start Signal • To Check EOC signal Chap 0 Serial Data Format Asynchronous Serial transmission to send data over long distance to a monitoring station   UART is commonly used Interfacing 10 or 12 bit ADC  Transfer data in chunks of 8 bits one after another 24 DAS (Data Acquisition System)  Chap 0 DAS performs the complete function of converting the raw outputs from one or more sensors into equivalent digital signals usable for further processing, control, or displaying applications  Applications Simple monitoring of a single analog variable  Control and Monitoring of hundreds of parameters in a nuclear plant  25 Single Channel System   Transducer   Generate signal of low amplitude, mixed with undesirable noise Amplifier, Filters Amplify  Remove noise  Linearize  S/H (Sample and Hold)  Reduce uncertainty error in the converted output when input changes are fast compared to the conversion time  In Multi-channel system   Chap 0 To hold a sample from one channel while multiplexer proceed to sample next one Simultaneous sampling of two signal 26 Sample and Hold Circuits  Care in selecting hold capacitor Ch  Low Value    High Value    Chap 0 Reduces acquisition time Increase Droop Minimize Droop Increase acquisition time Choose capacitor to get a best acquisition time while keeping the droop per conversion below 1 LSB 27 Commercially Available S/H Chap 0 28 Multi-channel System  Analog multiplexer and a ADC  Chap 0 Low cost  Local ADCs and digital multiplexer  Higher sampling rate 29 How to select and use an ADC  Range of commercially available ADCs  Guidelines for using ADCs Use the full input range of the ADC  Use a good source of reference signal  Look out for fast input signal changes  Keep analog and digital grounds separate  Minimize interference and loading problem  Chap 0 30 Commercially available monolithic ADCs Chap 0 31 Commercially available hybrid ADCs Chap 0 32 A low cost DAS for the IBM PC   Multi-channel system Less than $100  ADC0816 from National Semiconductor  Constant, repetitive rate   Chap 0 1000 samples/s Generating clock  For starting ADC conversion  For causing interrupt  Make a pulse stream from TCLK with short pulses of duration = ½ x BCLK/4  TCLK from 8253 Timer/Counter • Wide pulse 33 ADC circuit for PC prototype board SCSLCT (Start Conversion SeLeCT) : Latched trough port 30CH SCSLCT = H Selection of 30AH (/E10) start conversion SCSLCT = L TCLK’ start conversion INTSLCT (INTerrupt SeLeCT) : Latched trough port 30CH INTSLCT = H EOC cause IRQ2 INTSLCT = L No Interrupt CPU read Status register (Port 309H) to check EOC Chap 0 34 Status Register    Chap 0 For polling TCLK and EOC signal Port 309H (/E9) Polling of EOC results in a low level after the data from ADC have been read 35 Throughput rate calculation 4.77MHz / 8 = 596KHz Chap 0 36 Accuracy Calculation   Chap 0 Better than 1% accuracy is ensured Actual accuracy with smooth input signal at room temperature will be better than 0.5% 37 Basic Program for Controlling ADC Sampling rate < 200 samples/s Because OUT and IN instruction in Basic takes 5ms Chap 0 38 C Programming for Controlling ADC  Chap 0 Sampling from ADC channel 1 at 5ms interval and sending each sampled data point to the DAC 39 Homework #5-2  Prototype board의 회로 도를 참고하여 앞의 C program이 수행되는 과정을 해석하라  예를 들면 Outp(CNTRL,5)가 수행되면 회로도 에서 어떤 신호가 구동되는지 등…. Chap 0 40
 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
                                             
                                             
                                             
                                             
                                             
                                             
                                             
                                             
                                             
                                             
                                            