Transcript
Diagnostic and
Surgical Specialities
for Ophthalmology.
Medical Workshop BV
P.O.Box 461
9700 AL Groningen The Netherlands
Phone
Fax
E-mail
Website
+31 (0)50 5276 999
+31 (0)50 5276 958
service@medicalworkshop.nl
www.medicalworkshop.nl
Medical Workshop
In our over 50 years of existence, Medical Workshop
has become a well-known name on the international
ophthalmic market.
Over the years Medical Workshop has introduced a
number of new ophthalmic instruments.
Many of these instruments have become standard in
surgical procedures.
With this special catalogue we give a survey of our new
instrument line.
In addition to our specialities a complete range of
surgical instruments is available
Our present office in Groningen
Our premises in De Meern
The products in this catalog are subject to change in design without prior notification.
All rights reserved © 2015 Medical Workshop BV The Netherlands.
Mourits Exophthalmometer
Mourits Parallax-free exophthalmometer
This is a new standardized exophthalmometer, designed by Professor Mourits
of the VU University Medical Center. The most eyecatching innovation is it’s
parallax-free prismatic system. Both prisms can be slided individually,
providing quick and accurate measuring of the exophthalmus. The readout
is done in a single measurement, excluding mistakes when using a traditional
exophthalmometer.
Key features:
-
Parallax-free system.
Durable, lightweight design.
Accurate prismatic optics.
Patient friendly with smooth edges.
Easy to use.
MW-9500
Mourits exophthalmometer, supplied in case.
Slit Lamp Adapter
ErgAdap slit lamp adapter
The Medical Workshop ErgAdap slitlamp adapter is designed to create a
more ergonomic working angle for your slit lamp. Most slit lamps have
their microscopes fitted horizontally, but with the ErgAdap the microscope
will be tilted 20° to enhance comfort when working with your slit lamp over
a longer period.
The ErgAdap is a state-of-the-art product with excellent optics. Available
for the following slit lamps:
-
20°
Coherent LDS-10 laser slit lamp
Coherent LDS-20 laser slit lamp
CSO slit lamps
Ellex laser slit lamps
Lumenis laser slit lamp
Nidek SL-1600 slit lamp
Rodenstock RO-3000, RO-4000 and RO-5000
Takagi slit lamps
Topcon SL-D2 slit lamp
Topcon SL-D4 slit lamp
Topcon SL-D7 slit lamp
Topcon SL-D8Z slit lamp
Topcon SL-7F slit lamp
Topcon SL-8Z slit lamp
Zeiss 30 SL(M) slit lamp
Zeiss 20 SL slit lamp
Zeiss SL-130 slit lamp
MW-8000
ErgAdap (black) for Topcon type slit lamps (1).
MW-8130
ErgAdap (blue) for Zeiss SL-130 slit lamp.
MW-8150
ErgAdap for Rodenstock RO-3000/4000/5000.
ErgAdap on Rodenstock
(1)
ErgAdap on Topcon
In case of doubt, please contact your supplier for correct ErgAdap adapter.
Rustringremover
Rustringremover
The Medical Workshop Rustringremover has been part of our program for a long time and has been improved several times over the
years.
The instrument operates on one AA size penlight battery which is housed in
the handle. The Faulhaber® motor uses little energy and one battery should
deliver full power for the equivalent of three hours of continuous operation.
The motor is started by pressing the switch near the top of the instrument
handle.
Releasing the switch instantly stops the motor. The friction chuck is designed
to accomodate the specially designed (Medical Workshop) short shank dental
burr. An assortment of 6 burrs is included with the instrument. The sizes
have been carefully selected to handle most of the encountered rustring
sizes. Burrs are made of stainless steel.
The type of burr supplied performs a superficially scraping action (not a
drilling action) while there is no danger of perforating the cornea. The
instrument can be used with a slitlamp, a simple head loupe or even directly
(unmagnified). Only the burrs need sterilization. The instrument itself can
be wiped off occasionally with a little alcohol.
Key features:
-
Durable construction.
High tech Faulhaber® miniature motor.
Stainless steel burrs.
Elegant ergonomic design.
Instant stop switch.
Available with natural aluminum or blue handle
MW-111
Rustringremover* in case, with battery and
set of 6 standard burrs
MW-111A
Set of six standard burrs for the rustringremover,
three sizes, 010, 012 and 016
MW-111B
Set of six finest burrs for the rustringremover,
size 006
MW-111C
Empty case for rustringremover set
MW-111T
Empty case for burrs of the rustringremover
Lenses for Retinal Inspection and DCR
Contactlenses
For retinal inspection without having to dilate the iris or using a speculum,
improving patient’s comfort.
820012
Contactlens for prematures.
820013
Contactlens for infants.
DCR cap
Special protective contact lens during dacryocystorhinostomy procedures.
820010
DCR cap black
ERG lenses, Comberg & Barkan Lenses
MW-1126A
Lovac® Henkes electro retinography (ERG) lens,
standard model. Available in sizes large (Ø 20mm)
or small (Ø 17mm).
When ordering, please indicate large or small.
MW-1126B
Lovac® Henkes electro retinography (ERG) lens, with
100 diopter frontlens. Available in large (Ø 20mm)
or small (Ø 17mm).
When ordering, please indicate large or small.
MW-1120
Lovac® Comberg contact lens for X-ray localization.
MW-1120A
Transparent reference scheme for use with the
Comberg lens (Not illustrated).
MW-1120C
Pack of 250 recording sheets for the Comberg lens
(Not ilustrated).
MW-1121
Lovac® Barkan gonio lens, spherical,
2x magnification.
Goniotomy Lenses, Fluid Filter
Goniotomy lenses
MW-1122A
Spherical goniotomylens, large model,
2x magnification, with cannula for irrigation.
MW-1122B
Spherical goniotomylens, small model,
2x magnification, with cannula for irrigation.
MW-1122C
Prismatic goniotomylens, large model, without
magnification for use with the operation microscope,
with cannula for irrigation.
MW-1122D
Prismatic goniotomylens, small model, without
magnification for use with the operation microscope,
with cannula for irrigation.
MW-120F
Optex® disposable fluid filter, sterile, single use.
Box of 50 units.
MW-200 Gonçalves InVitria®
The Gonçalves InVitria® Intra Vitreal Injection Assistant is
a disposable device that simplifies intravitreal anti-VEGF
injections.
The special design with a fixed injectionangle, -position
and -depth ensures a predictable procedure.
Key features
•
•
•
•
•
•
•
No speculum needed
No caliper needed
No pressure plate needed
Single use
User friendly
Patient friendly
Budget friendly
Fixed angle 28°
Ergonomic grip
Positioning line for orientation
on the limbus
Flange for optimal positioning
and control
Fixed depth 5.60mm
Fixed distance 3.5mm from the limbus
The InVitria® was developed in cooperation with dr. Arnaldo Gonçalves from Holland.
Patent pending
Disposable Trephines
Key features:
-
Manufactured of case hardened stainless
steel.
Sharpness surpasses all existing trephines.
Half-open handle design for accurate
positioning.
Knurled handle and central pivot for stable
fingertip rotation.
Non-glare finish.
Blade thickness only 0.09 mm.
Gamma sterilized
Ready for use
Disposable supersharp trephines
The sharpness of the Medical Workshop disposable trephines is much higher
than any conventional trephine. The sectioning technique requires hardly
any pressure. Therefore, care must be taken when using these trephines
for the first time. However, due to the extreme sharpness, the incision
causes less than the usual deformation and distortion and gives no wedge
formation.
MW-4650
MW-4675
MW-4700
MW-4725
MW-4750
MW-4775
MW-4800
MW-4825
MW-4850
MW-4875
MW-4900
MW-4925
MW-4950
Disposable
Disposable
Disposable
Disposable
Disposable
Disposable
Disposable
Disposable
Disposable
Disposable
Disposable
Disposable
Disposable
corneal trephine Ø 6.75mm.
corneal trephine Ø 6.75mm.
corneal trephine Ø 7.00mm.
corneal trephine Ø 7.25mm.
corneal trephine Ø 7.50mm.
corneal trephine Ø 7.75mm.
corneal trephine Ø 8.00mm.
corneal trephine Ø 8.25mm.
corneal trephine Ø 8.50mm.
corneal trephine Ø 8.75mm.
corneal trephine Ø 9.00mm.
corneal trephine Ø 9.25mm.
corneal trephine Ø 9.50mm.
MW-4000
Punch block for cutting donor cornea, for use with
Medical Workshop disposable trepnines.
MW-4005
Black teflon replacement insert for punch block
base.
MW-4010
Silicone replacement insert for punch block base.
Tearduct, Cataract Surgery, Goniotomy
Lacrimal probes
Medical Workshop lacrimal probes for tear duct reconstruction. Available
as standard curved probe or irrigating probe
MW-106
Lacrymal probe, available in sizes 0.5mm, 0.8mm
and 1.0mm
MW-109
Irrigating lacrymal probe, including tubing and
cannula, available in sizes 0.5mm, 0.8mm and
1.0mm.
MW-112H
Pigtailprobe
with
hole
for
tearduct
reconstruction.
Comes with set of silicone tubing MW-112S.
MW-112S
Set of 50cm silicone tubing (not illustrated).
MW-115
Twistgrip for scleral fixation in muscle surgery,
cataract surgery, retinal detachment, etc.
MW-113
Hydrostatic needleholder with three needles for
goniotomy. Supplied with 3 needles, silicone tubing
and Luer Lock cone
MW-113A
Set of 3 spare needles for MW-113.
Pressure Reducer, Corneal Marker
Intra ocular pressure reducer
The Medical Workshop Intra ocular pressure reducer is to be used for
reducing intraocular pressure prior to surgical procedures, like cataract
surgery, glaucoma surgery, IOL implantation and keratoplasty. The headband
is made of special patient-friendly elastic material and velcro strap for
secure fixation.
The instrument consists of:
- Balloon
- Elastic headband
- Silicone tubing
- Pressure reducer gauge
- Storage wallet
Key features:
- Lightweight design
- Large, accurate display
- Exchangable balloon and headband
MW-6000
Medical Workshop intraocular pressure reducer,
complete set.
MW-6005
Spare balloon on aluminium housing.
MW-6010
Spare elastic headband.
Luyten’s Optimark corneal marker
Special designed corneal marker for placing a crossmark on the patient’s
eye when in upright position. The corneal curve normally changes when
patients are moved to horizontal position, but when using the Optimark
you can determine the center of the cornea while the patient is still sitting
behind your slit lamp.
After the doubling-prism of the applanation tonometer is removed, the
Optimark is moistured on a sterile inkpad and placed on the tonometer.
Now a cross is marked can be placed on the patient’s cornea.
When the patient is moved to a horizontal position, the cross gives the
correct position.
MW-8500
Optimark corneal marker for use on slitlamp
tonometer.
The Optimark corneal marker is designed together with Professor Luyten
of the Leiden university hospital.
Orthoptic Instruments
MW-122
Gobin’s prism test for testing binocular vision.
Standard version is 15 prism diopter.
Also available in 4 prism diopter.
Supplied with table support.
Principle of the Gobin’s prism test:
One eye moves
= binocular vision.
The light reflex remains in place.
No eye moves
= suppression of the eye behind the prism.
The light reflex moves nasal on this eye.
Both eyes move
= suppression of the eye without prism.
The light reflex moves now onto the eye without prism.
Occluding spectacles
For use with visual acuity testing.
Made of non-transparent durable white plastic with velcro fixation strap.
MW0040
Occluding spectacle Leiden model, for children
MW0041
Occluding spectacle Leiden model, for adults
Your distributor