SYNCHRONOUS MACHINES Copyright © P. Kundur This material should not be used without the author's consent 1539pk Synchronous Machines Outline 1. Physical Description 2. Mathematical Model 3. Park's "dqo" transportation 4. Steady-state Analysis  phasor representation in d-q coordinates  link with network equations 5. Definition of "rotor angle" 6. Representation of Synchronous Machines in Stability Studies  neglect of stator transients  magnetic saturation 7. Simplified Models 8. Synchronous Machine Parameters 9. Reactive Capability Limits SM - 1 1539pk Physical Description of a Synchronous Machine  Consists of two sets of windings:  3 phase armature winding on the stator distributed with centres 120° apart in space  field winding on the rotor supplied by DC  Two basic rotor structures used:  salient or projecting pole structure for hydraulic units (low speed)  round rotor structure for thermal units (high speed)  Salient poles have concentrated field windings; usually also carry damper windings on the pole face. Round rotors have solid steel rotors with distributed windings  Nearly sinusoidal space distribution of flux wave shape obtained by:  distributing stator windings and field windings in many slots (round rotor);  shaping pole faces (salient pole) SM - 2 1539pk Rotors of Steam Turbine Generators  Traditionally, North American manufacturers normally did not provide special “damper windings”  solid steel rotors offer paths for eddy currents, which have effects equivalent to that of amortisseur currents  European manufacturers tended to provide for additional damping effects and negative-sequence current capability  wedges in the slots of field windings interconnected to form a damper case, or  separate copper rods provided underneath the wedges Figure 3.3: Solid round rotor construction SM - 3 1539pk Rotors of Hydraulic Units  Normally have damper windings or amortisseurs  non-magnetic material (usually copper) rods embedded in pole face  connected to end rings to form short-circuited windings  Damper windings may be either continuous or noncontinuous  Space harmonics of the armature mmf contribute to surface eddy current  therefore, pole faces are usually laminated Figure 3.2: Salient pole rotor construction SM - 4 1539pk Balanced Steady State Operation  Net mmf wave due to the three phase stator windings:  travels at synchronous speed  appears stationary with respect to the rotor; and  has a sinusoidal space distribution  mmf wave due to one phase: Figure 3.7: Spatial mmf wave of phase a SM - 5 1539pk Balanced Steady State Operation  The mmf wave due to the three phases are: MMFa  Ki a cos  ia  Im cos s t  2   MMFb  Kib cos    3   2   ib  Im cos  s t   3   2   MMFc  Ki c cos    3   2   ia  lm cos  s t   3   MMFtotal  MMFa  MMFb  MMFc  3 KIm cos  s t  2 SM - 6 1539pk Balanced Steady State Operation  Magnitude of stator mmf wave and its relative angular position with respect to rotor mmf wave depend on machine output  for generator action, rotor field leads stator field due to forward torque of prime mover;  for motor action rotor field lags stator field due to retarding torque of shaft load Figure 3.8: Stator and rotor mmf wave shapes SM - 7 1539pk Transient Operation  Stator and rotor fields may:  vary in magnitude with respect to time  have different speed  Currents flow not only in the field and stator windings, but also in:  damper windings (if present); and  solid rotor surface and slot walls of round rotor machines Figure 3.4: Current paths in a round rotor SM - 8 1539pk Direct and Quadrature Axes  The rotor has two axes of symmetry  For the purpose of describing synchronous machine characteristics, two axes are defined:  the direct (d) axis, centered magnetically in the centre of the north pole  The quadrature (q) axis, 90 electrical degrees ahead of the d-axis Figure 3.1: Schematic diagram of a 3-phase synchronous machine SM - 9 1539pk Mathematical Descriptions of a Synchronous Machine  For purposes of analysis, the induced currents in the solid rotor and/or damper windings may be assumed to flow in two sets of closed circuits  one set whose flux is in line with the d-axis; and  the other set whose flux is along the q-axis  The following figure shows the circuits involved Figure 3.9: Stator and rotor circuits SM - 10 1539pk Review of Magnetic Circuit Equations (Single Excited Circuit)  Consider the elementary circuit of Figure 3.10 ei  d dt e1  d  ri dt   Li  The inductance, by definition, is equal to flux linkage per unit current LN   N2P i where P = permeance of magnetic path > = flux = (mmf) P = NiP Figure 3.10: Single excited magnetic circuit SM - 11 1539pk Review of Magnetic Circuit Equations (Coupled Circuits)  Consider the circuit shown in Figure 3.11 e1  d1  r1i1 dt e2  d2  r2i2 dt 1  L11i1  L 21i2 2  L 21i1  L 22 i2 with L11 = self inductance of winding 1 L22 = self inductance of winding 2 L21 = mutual inductance between winding 1 and 2 Figure 3.11: Magnetically coupled circuit SM - 12 1539pk Basic Equations of a Synchronous Machine  The equations are complicated by the fact that the inductances are functions of rotor position and hence vary with time  The self and mutual inductances of stator circuits vary with rotor position since the permeance to flux paths vary Iaa  L al  Igaa  L aa 0  L aa 2 cos 2 2   Iab  Iba  L ab 0  L ab 2 cos  2   3      L ab 0  L ab 2 cos  2   3   The mutual inductances between stator and rotor circuits vary due to relative motion between the windings Iafd  L afd cos  Iakd  L akd cos    Iakq  L akq cos      L akq sin  2  SM - 13 1539pk Basic Equations of a Synchronous Machine  Dynamics of a synchronous machine is given by the equations of the coupled stator and rotor circuits  Stator voltage and flux linkage equations for phase a (similar equations apply to phase b and phase c) ea  da  R aia  pa  R aia dt a  laa ia labib  lac ic  lafdifd  lakd ikd  lakq ikq  Rotor circuit voltage and flux linkage equations e fd  pfd  R fdifd 0  pkd  R kdikd 0  pkq  R kqikq  fd  L ffdifd  L fkdikd  2  2      L afd ia cos   ib cos      ic cos     3 3       kd  L fkdifd  Lkkd ikd  2  2      L afd ia cos   ib cos      ic cos     3 3       kq  Lkkd ikq  2  2      L akq ia sin   ib sin      ic sin     3 3      SM - 14 1539pk The dqo Transformation  The dqo transformation, also called Park's transformation, transforms stator phase quantities from the stationary abc reference frame to the dqo reference frame which rotates with the rotor  2  2     cos     cos      cos  3 3      id  i   2   sin   sin    2   sin    2    q 3  3  3    i  1  0 1 1   2 2   2 ia  ib  i   c The above transformation also applies to stator flux linkages and voltages  With the stator quantities expressed in the dqo reference frame  all inductances are independent of rotor position (except for the effects of magnetic saturation)  under balanced steady state operation, the stator quantities appear as dc quantities  during electromechanical transient conditions, stator quantities vary slowly with frequencies in the range of 1.0 to 3.0 Hz The above simplify computation and analysis of results. SM - 15 1539pk Physical Interpretation of dqo Transformation  The dqo transformation may be viewed as a means of referring the stator quantities to the rotor side  In effect, the stator circuits are represented by two fictitious armature windings which rotate at the same speed as the rotor; such that:  the axis of one winding coincides with the d-axis and that of the other winding with the q-axis  The currents id and iq flowing in these circuits result in the same mmf's on the d- and q-axis as do the actual phase currents  The mmf due to id and iq are stationary with respect to the rotor, and hence:  act on paths of constant permeance, resulting in constant self inductances (Ld, Lq) of stator windings  maintain fixed orientation with rotor circuits, resulting in constant mutual inductances SM - 16 1539pk Per Unit Representation  The per unit system is chosen so as to further simplify the model  The stator base quantities are chosen equal to the rated values  The rotor base quantities are chosen so that:  the mutual inductances between different circuits are reciprocal (e.g. Lafd = Lfda)  the mutual inductances between the rotor and stator circuits in each axis are equal (e.g., Lafd = Lakd) The P.U. system is referred to as the "Lad base reciprocal P.U. system"  One of the advantages of having a P.U. system with reciprocal mutual inductances is that it allows the use of equivalent circuits to represent the synchronous machine characteristics SM - 17 1539pk P.U. Machine Equations in dqo reference frame  The equations are written with the following assumptions and notations:  t is time in radians  p = d/dt  positive direction of stator current is out of the machine  each axis has 2 rotor circuits  Stator voltage equations e d  p d   qr  R aid e q  p q   dr  R aiq e 0  p 0  R ai0  Rotor voltage equations e fd  p fd  R fdifd 0  p 1d  R 1di1d 0  p 1q  R 1qi1q 0  p 2q  R 2qi2q SM - 18 1539pk P.U. Machine Equations in dqo Reference Frame (cont'd)  Stator flux linkage equations  d  Lad  Ll  id  Lad ifd  Lad i1d  q  Laq  Ll  iq  Laq i1q  Laq i 2 q  0  L0 i0  Rotor flux linkage equations  fd  L ffdifd  L f 1di1d  L adid  1d  L f 1difd  L11di1d  L adid  1q  L11qi1q  L aqi2q  L aqiq  1q  L aqi1q L 22 qL 2q  L aqiq  Air-gap torque T e   diq   qid SM - 19 1539pk Steady State Analysis Phasor Representation For balanced, steady state operation, the stator voltages may be written as: e a  Em cos t    eb  Em cos t  2 3    e c  Em cos t  2 3    with ω = angular velocity = 2πf α = phase angle of ea at t=0 Applying the d,q transformation, ed  Em cos t     eq  Em sin t     At synchronous speed, the angle θ is given by θ = ωt + θ0 with θ = value of θ at t = 0 Substituting for θ in the expressions for ed and eq, e d  Em cos   0  e q  Em sin   0  SM - 20 1539pk Steady State Analysis Phasor Representation (cont'd)  The components ed and eq are not a function of t because rotor speed ω is the same as the angular frequency ω of the stator voltage. Therefore, ed and eq are constant under steady state. In p.u. peak value Em is equal to the RMS value of terminal voltage Et. Hence, e d  E t cos  0  e q  E t sin  0   The above quantities can be represented as phasors with d-axis as real axis and q-axis as imaginary axis Denoting δi, as the angle by which q-axis leads E e d  E t sin i e q  E t cos i SM - 21 1539pk Steady State Analysis Phasor Representation (cont'd)  The phasor terminal voltage is given by ~ in the d-q coordinates E t  ed  je q  E R  jE l in the R-I coordinates  This provides the link between d,q components in a reference frame rotating with the rotor and R, I components associated with the a.c. circuit theory  Under balanced, steady state conditions, the d,q,o transformation is equivalent to  the use of phasors for analyzing alternating quantities, varying sinusoidally with respect to time  The same transformation with θ = ωt applies to both  in the case of machines, ω = rotor speed  in the case of a.c. circuits, ω = angular frequency SM - 22 1539pk Internal Rotor Angle  Under steady state ed   q  idR a  Lqiq  idR a  X qiq idR a Similarly eq   d  iqR a   X did  X adifd  iqR a  Under no load, id=iq=0. Therefore,  q  L qiq  0  d  L adifd ed  0 e q  L adifd ~ E and t  e d  jeq  jLadifd  Under no load, Et has only the q-axis component and δi=0. As the machine is loaded, δi increases. Therefore, δi is referred to as the load angle or internal rotor angle.  It is the angle by which q-axis leads the phasor Et SM - 23 1539pk Electrical Transient Performance  To understand the nature of electrical transients, let us first consider the RL circuit shown in Figure 3.24 with e = Emsin (ωt+α). If switch "S" is closed at t=0, the current is given by eL solving i  Ke   Lt R  di  iR dt Em sint     Z The first term is the dc component. The presence of the dc component ensures that the current does not change instantaneously. The dc component decays to zero with a time constant of L/R Figure 3.24: RL Circuit SM - 24 1539pk Short Circuit Currents of a Synchronous Machine  If a bolted three-phase fault is suddenly applied to a synchronous machine, the three phase currents are shown in Figure 3.25. Figure 3.25: Three-phase short-circuit currents SM - 25 1539pk Short Circuit Currents of a Synchronous Machine (cont'd)  In general, fault current has two distinct components: a) a fundamental frequency component which decays initially very rapidly (a few cycles) and then relatively slowly (several seconds) to a steady state value b) a dc component which decays exponentially in several cycles  This is similar to the short circuit current in the case of the simple RL circuit. However, the amplitude of the ac component is not constant  internal voltage, which is a function of rotor flux linkages, is not constant  the initial rapid decay is due to the decay of flux linking the subtransient circuits (high resistance)  the slowly decaying part of the ac component is due to the transient circuit (low resistance)  The dc components have different magnitudes in the three phases SM - 26 1539pk Elimination of dc Component by Neglecting Stator Transients  For many classes of problems, considerable computational simplicity results if the effects of ac and dc components are treated separately  Consider the stator voltage equations ed  p d    q  idR a eq  p q    d  iqR a transformer voltage terms: pψd, pψq speed voltage terms:   q ,   d  The transformer voltage terms represent stator transients:  stator flux linkages (ψd, ψq) cannot change instantaneously  result in dc offset in stator phasor current  If only fundamental frequency stator currents are of interest, stator transients (pψd, pψq) may be neglected. SM - 27 1539pk Short Circuit Currents with Stator Transients Neglected  The resulting stator phase currents following a disturbance has the wave shape shown in Figure 3.27  The short circuit has only the ac component whose amplitude decays  Regions of subtransient, transient and steady state periods can be readily identified from the wave shape of phase current Figure 3.27: Fundamental frequency component of short circuit armature current SM - 28 1539pk Synchronous Machine Representation in System Stability Studies  Stator Transients (pψd, pψq) are usually neglected  accounts for only fundamental frequency components of stator quantities  dc offset either neglected or treated separately  allows the use of steady-state relationships for representing the transmission network  Another simplifying assumption normally made is setting   1 in the stator voltage equations  counter balances the effect of neglecting stator transients so far as the low-frequency rotor oscillations are concerned  with this assumption, in per unit air-gap power is equal to air-gap torque (See section 5.1 of book for details) SM - 29 1539pk Equation of Motion (Swing Equation)  The combined inertia of the generator and primemover is accelerated by the accelerating torque: J dm  Ta  Tm  Te dt where Tm = mechanical torque in N-M Te = electromagnetic torque in N-m J combined moment of inertia of generator and turbine, kg•m2 = am = angular velocity of the rotor in mech. rad/s t time in seconds = SM - 30 1539pk Equation of Motion (cont'd)  The above equation can be normalized in terms of per unit inertia constant H 1 J20m H 2 VAbase where a0m = rated angular velocity of the rotor in mechanical radians per second  Equation of motion in per unit form is 2H d r  Tm  Te dt where r  m 0m Tm  Tm0m VAbase = per unit mechanical torque Te  Te 0m VAbase = per unit electromechanical torque  = per unit rotor angular velocity Often inertia constant M = 2H used SM - 31 1539pk Magnetic Saturation  Basic equations of synchronous machines developed so far ignored effects of saturation  analysis simple and manageable  rigorous treat a futile exercise  Practical approach must be based on semiheuristic reasoning and judiciously chosen approximations  consideration to simplicity, data availability, and accuracy of results  Magnetic circuit data essential to treatment of saturation given by the open-circuit characteristic (OCC) SM - 32 1539pk Assumptions Normally Made in the Representation of Saturation  Leakage inductances are independent of saturation  Saturation under loaded conditions is the same as under no-load conditions  Leakage fluxes do not contribute to iron saturation  degree of saturation determined by the air-gap flux  For salient pole machines, there is no saturation in the q-axis  flux is largely in air  For round rotor machines, q-axis saturation assumed to be given by OCC  reluctance of magnetic path assumed homogeneous around rotor periphery SM - 33 1539pk  The effects of saturation is represented as L ad  K sdL adu L aq  K sqL aqu (3.182) (3.183) Ladu and Laqu are unsaturated values. The saturation factors Ksd and Ksq identify the degrees of saturation.  As illustrated in Figure 3.29, the d-axis saturation is given by The OCC.  Referring to Figure 3.29, I  at 0  at (3.186) at at  I (3.187) K sd   For the nonlinear segment of OCC, I can be expressed by a suitable mathematical function: I  Asat eBsat at TI SM - 34 (3.189) 1539pk Open-Circuit Characteristic (OCC)  Under no load rated speed conditions id  iq  q  ed  0 Et  eq  d  Ladifd  Hence, OCC relating to terminal voltage and field current gives saturation characteristic of the d-axis Figure 3.29: Open-circuit characteristic showing effects of saturation SM - 35 1539pk  For salient pole machines, since q-axis flux is largely in air, Laq does not vary significantly with saturation  Ksq=1 for all loading conditions  For round rotor machines, there is saturation in both axes  q-axis saturation characteristic not usually available  the general industry practice is to assume Ksq = Ksd  For a more accurate representation, it may be desirable to better account for q-axis saturation of round rotor machines  q-axis saturates appreciably more than the daxis, due to the presence of rotor teeth in the magnetic path  Figure 3.32 shows the errors introduced by assuming q-axis saturation to be same as that of d-axis, based on actual measurements on a 500 MW unit at Lambton GS in Ontario  Figure shows differences between measured and computed values of rotor angle and field current  the error in rotor angle is as high as 10%, being higher in the underexcited region  the error in the field current is as high as 4%, being greater in the overexcited region SM - 36 1539pk  The q-axis saturation characteristic is not readily available  It can, however, be fairly easily determined from steady-state measurements of field current and rotor angle at different values of terminal voltage, active and reactive power output  Such measurements also provide d-axis saturation characteristics under load  Figure 3.33 shows the d- and q-axis saturation characteristics derived from steady-state measurements on the 500 MW Lambton unit Figure 3.33: Lambton saturation curves derived from steady-state field current and rotor angle measurements SM - 37 1539pk Example 3.3  Considers the 555 MVA unit at Lambton GS and examines  the effect of representing q-axis saturation characteristic distinct from that of d-axis  the effect of reactive power output on rotor angle  Table E3.1 shows results with q-axis saturation assumed same as d-axis saturation Table E3.1  Pt Qt Ea (pu) Ksd δi (deg) ifd (pu) 0 0 1.0 0.889 0 0.678 0.4 0.2 1.033 0.868 25.3 1.016 0.9 0.436 1.076 0.835 39.1 1.565 0.9 0 1.012 0.882 54.6 1.206 0.9 -0.2 0.982 0.899 64.6 1.089 Table E3.2 shows results with distinct d- and q-axis saturation representation Table E3.2 Pt Qt Ksq Ksd δi (deg) ifd (pu) 0 0 0.667 0.889 0 0.678 0.4 0.2 0.648 0.868 21.0 1.013 0.9 0.436 0.623 0.835 34.6 1.559 0.9 0 0.660 0.882 47.5 1.194 0.9 -0.2 0.676 0.899 55.9 1.074 SM - 38 1539pk Simplified Models for Synchronous Machines  Neglect of Amortisseurs  first order of simplification  data often not readily available  Classical Model (transient performance)  constant field flux linkage  neglect transient saliency (x'd = x'q) E´  Et xd Steady-state Model  constant field current  neglect saliency (xd = xq = xs) Et Eq xs Eq = Xadifd SM - 39 1539pk Reactive Capability Limits of Synchronous Machines  In voltage stability and long-term stability studies, it is important to consider the reactive capability limits of synchronous machines  Synchronous generators are rated in terms of maximum MVA output at a specified voltage and power factor which can be carried continuously without overheating  The active power output is limited by the prime mover capability  The continuous reactive power output capability is limited by three considerations  armature current limit  field current limit  end region heating limit SM - 40 1539pk Armature Current Limit  Armature current results in power loss, and the resulting heat imposes a limit on the output The per unit complex output power is ~ * S  P  jQ  E t ~I t  E t It cos   j sin  where Φ is the power factor angle  In a P-Q plane the armature current limit, as shown in Fig. 5.12, appears as a circle with centre at the origin and radius equal to the MVA rating Fig 5.12: Armature current heating limit SM - 41 1539pk Field Current Limit  Because of the heating resulting from RfdI2fd power loss, the field current imposes the second limit  The phasor diagram relating Et, It and Eq (with Ra neglected) is shown in Fig. 5.13 Equating the components along and perpendicular to the phasor Et X adifd sin i  X slt cos  X adifd cos i  Et  X slt sin  Therefore X ad E tifd sin i Xs X E2 Q  E tlt sin   ad E tifd cos i  t Xs Xs P  E tlt cos    The relationship between P and Q for a given field current is a circle centered at on the Q-axis and with as the radius. The effect of the maximum field current on the capability of the machine is shown in Fig. 5.14  In any balanced design, the thermal limits for the field and armature intersect at a point (A) which represents the machine name-plate MVA and power factor rating SM - 42 1539pk Field Current Limit Fig. 5.13: Steady state phasor diagram Fig. 5.14: Field current heating limit SM - 43 1539pk End Region Heating Limit  The localized heating in the end region of the armature affects the capability of the machine in the underexcited condition  The end-turn leakage flux, as shown in Fig. 5.15, enters and leaves in a direction perpendicular (axial) to the stator lamination. This causes eddy currents in the laminations resulting in localized heating in the end region  The high field currents corresponding to the overexcited condition keep the retaining ring saturated, so that end leakage flux is small. However, in the underexcited region the field current is low and the retaining ring is not saturated; this permits an increase in armature end leakage flux  Also, in the underexcited condition, the flux produced by the armature current adds to the flux produced by the field current. Therefore, the end-turn flux enhances the axial flux in the end region and the resulting heating effect may severely limit the generator output, particularly in the case of a round rotor machine  Fig. 5.16 shows the locus of end region heating limit on a P-Q plane SM - 44 1539pk End Region Heating Limit Fig. 5.15: Sectional view end region of a generator Fig. 5.16: End region heating limit SM - 45 1539pk Reactive Capability Limit of a 400 MVA Hydrogen Cooled Steam Turbine Generator  Fig. 5.18 shows the reactive capability curves of a 400 MVA hydrogen cooled steam turbine driven generator at rated armature voltage  the effectiveness of cooling and hence the allowable machine loading depends on hydrogen pressure  for each pressure, the segment AB represents the field heating limit, the segment BC armature heating limit, and the segment CD the end region heating limit Fig. 5.18: Reactive capability curves of a hydrogen cooled generator at rated voltage SM - 46 1539pk Effect of Changes in Terminal Voltage Et Fig. 5.17: Effect of reducing the armature voltage on the generator capability curve SM - 47 1539pk
 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
                                             
                                             
                                             
                                             
                                             
                                             
                                             
                                             
                                             
                                             
                                            