* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download IID System Impact Study Data Requirements
Electrification wikipedia , lookup
Power engineering wikipedia , lookup
History of electric power transmission wikipedia , lookup
Buck converter wikipedia , lookup
Three-phase electric power wikipedia , lookup
Voltage optimisation wikipedia , lookup
Switched-mode power supply wikipedia , lookup
IID System Impact Study Data Requirements System Impact Studies typically includes power flow, stability, and short circuit analysis. IID may determine that one of these analyses is not required. Power Flow Stability Short circuit PSLF version to be used for the Power Flow Study: PSLF 14.2 PSLF 15.1 A) Power Flow System data Please provide the following information. If additional space is needed, for example multiple load and line additions, please copy the form. 1) Project Name What is the name of the project? (Please provide 3 different alternatives) Alternative 1. Alternative 2 . Alternative 3. 2) Project One-Line Diagram Please provide a simplified 1-line diagram of the facility (ies) to be studied. 3) Will this project be completed in phases? Yes No 4) If yes, what year or year(s) should be modeled for each phase? 5) If no, what is your proposed in-service date? 6) What season you propose to be modeled? (Please mark boxes with an “X”) Season Spring Summer Autumn Winter 769855665j jb 5/4/2017, 5:12:45 AM Heavy Condition Light Condition 7) Provide a map with geographical location of the new generation project and distances between the project and other important points in the area. (Please attached to this form) 8) Propose Point of Interconnection to the IID System (Station and kV): 9) Energy Delivery Point (Control Area, Substation and kV): 10) Is the project a peaking or base load project? 11) Provide the company’s name owner of this generator: 12) Should internal IID generation be reduced to offset project in the post project condition? 13) Should this project energy be exported to other Control Area? Yes No 14) If yes, which Control Area, Substation and kV? 15) EQUIPMENT DATA. (Nameplate data is acceptable also) Generator A: Generator Data MW MVAR Power Factor 769855665j jb 5/4/2017, 5:12:45 AM Peak Min. ANNUAL Peak Max. Off Peak Min. Off Peak Max. Generator B: Generator Data MW MVAR Power Factor Peak Min. ANNUAL Peak Max. Off Peak Min. Off Peak Max. Peak Min. ANNUAL Peak Max. Off Peak Min. Off Peak Max. Peak Min. ANNUAL Peak Max. Off Peak Min. Off Peak Max. Load 1: Generator Data MW MVAR Power Factor Load 2: Generator Data MW MVAR Power Factor Generator Step-up Transformer 1: Low Side Voltage (kV) MVA Base (MVA) Continuous Rating (MVA) Number of Transformers High Side Voltage Reactance (p.u.) or % Emergency Rating (MVA) Transformer Connection Generator Step-up Transformer 2: Low Side Voltage (kV) MVA Base (MVA) Continuous Rating (MVA) Number of Transformers High Side Voltage Reactance (p.u.) or % Emergency Rating (MVA) Transformer Connection System Step-up Transformer: Low Side Voltage (kV) MVA Base (MVA) Continuous Rating (MVA) Number of Transformers High Side Voltage Reactance (p.u.) or % Emergency Rating (MVA) Transformer Connection 769855665j jb 5/4/2017, 5:12:45 AM 16) INTERCONNECTING LINE. The gray cells are optional, if the conductor type, length and characteristics are provided. Conductor Type Single Circuit Single Conductor Voltage (kV) Optional: Resistance (R), p.u. MVA Rating Yes Yes No No Length Double Circuit Bundled Conductor Feet Yes Yes Miles No No Reactance (X), p.u. Suseptance (B), p.u. 17) Provide the contact person name, telephone number and email for questions on the Power Flow data provided. 769855665j jb 5/4/2017, 5:12:45 AM B) Stability Study Data Each generator interconnection project must have the appropriate dynamics model provided including the model name and all parameters associated with each model in General Electric (PSLF) format. From the following model list, select the model that matches the new generator that you need to connect to the IID System. Once you select the model, we will provide you the electronic file with the model template for you to update the data according to the information provided to you by the generator manufacturer: MACHINE MODELS Model Name Description Gencc Generator represented by uniform inductance ratios rotor modeling to match WSCC type F model; shaft speed effects are neglected. Intended to model cross-compound machines represented as one generator in the load flow. Gencls Synchronous machine represented by "classical" modeling or Thevenin Voltage Source to Play Back known voltage/frequency signal Genrou Solid rotor generator represented by equal mutual inductance rotor modeling Gensal Salient pole generator represented by equal mutual inductance rotor modeling Gensdo Generator with stator d.c. current represented Gentpf Generator represented by uniform inductance ratios rotor modeling to match WSCC type F model; shaft speed effects are neglected Genwri Wound-rotor induction generator model (with variable external rotor resistance) Gewtg Generator/converter model for GE wind turbines Motor1 "Two-cage" or "one-cage" induction machine Shaft5 Call GE 769855665j jb 5/4/2017, 5:12:45 AM EXCITATION MODELS Model Name Description Esac2a IEEE (1992/2005) type AC2A excitation system Esac3a IEEE (1992/2005) type AC3A excitation system Esac7b IEEE (2005) type AC7B excitation system Exac1 IEEE type AC1 excitation system Exac1a Modified IEEE type AC1 excitation system Exac2 IEEE type AC2 excitation system Exac3 IEEE type AC3 excitation system Exac3a IEEE type AC3 excitation system Exac4 IEEE type AC4 excitation system Exac6a IEEE type AC6A excitation system Exac8b Brushless exciter with PID voltage regulator exbbc Transformer fed static excitation system Exdc1 IEEE type 1 excitation system model Represents systems with d.c. exciters and continuously acting voltage regulators, such as amplidynebased excitation systems Exdc2 IEEE type 2 excitation system model Represents systems with d.c. exciters and continuously acting voltage regulators, such as amplidynebased excitation systems Exdc2a IEEE type 2 excitation system model Represents systems with d.c. exciters and continuously acting voltage regulators, such as amplidynebased excitation systems Exeli Static PI transformer fed excitation system 769855665j jb 5/4/2017, 5:12:45 AM Exst1 IEEE type ST1 excitation system Exst2 IEEE type ST2 excitation system Exst2a IEEE type ST2 excitation system Exst3 IEEE type ST3 excitation system Exst3a IEEE type ST3 excitation system Exst4b IEEE type ST4b excitation system Exwtg1 Excitation system model for wound-rotor induction wind-turbine generator Extwge Excitation (converter) control model for GE wind-turbine generators Ieeetl "Old" IEEE type 1 excitation system model. Represents systems with d.c. exciters and continuously acting voltage regulators, such as amplidynebased excitation systems Mexs Manual excitation control with field circuit resistance Pfqrg Power factor / Reactive power regulator Rexs General Purpose Rotating Excitation System Model Scrx Simple excitation system model representing generic characteristics of many excitation systems; intended for use where negative field current may be a problem Sexs Standard excitation system model representing generic characteristics of many excitation systems; intended for use where details of the actual excitation system are unknown and/or unspecified Texs General Purpose Transformer Fed Excitation System Model 769855665j jb 5/4/2017, 5:12:45 AM PRIME MOVER MODELS Model Name Description Ccbtl Steam plant boiler / turbine and governor Ccst3 Combined Cycle Plant Steam Turbine Model Crcmgy Cross compound turbine governor model G2wscc Double derivative hydro governor and turbine. (Represents WECC G2 governor plus turbine model.) Gast Single shaft gas turbine Gegt1 General Electric Frame 6, 7, 9 Gas Turbine Model Ggov1 General governor model Ggov2 General governor model with frequency-dependent fuel flow limit Gpwscc PID governor and turbine. (Represents WECC GP governor plus turbine model.) Hyg3 PID governor, double derivative governor and turbine. (Represents WECC GP governor, WECC G2 governor plus turbine model.) hygov Hydro turbine and governor. Represents plants with straight forward penstock configurations and electro-hydraulic governors that mimic the permanent/temporary droop characteristics of traditional dashpottype hydraulic governors. Hygov4 Hydro turbine and governor. Represents plants with straight forward penstock configurations and hydraulic governors of traditional 'dashpot' type. 769855665j jb 5/4/2017, 5:12:45 AM hystl Hydro turbine with Woodward Electro-hydraulic PID Governor, Penstock, Surge Tank, and Inlet Tunnel Ieeeg1 IEEE steam turbine/governor model (with deadband and nonlinear valve gain added) Ieeeg3 IEEE hydro turbine/governor model. Represents plants with straightforward penstock configurations and hydraulic-dashpot governors. (Optional deadband and nonlinear gain added.) 1cfb1 Turbine Load Controller model 1m6000 LM6000 Aero-derivative gas turbine governor Pfs Pre-programmed Frequency Source Pidgov Hydro turbine and governor. Represents plants with straight forward penstock configurations and "three term" electro-hydraulic governors (i.e. Woodard electronic) Stag1 Single Shaft Combined-Cycle Plant Model Tgov1 Basic steam turbine and governor Tgov3 Turbine/governor model with fast valving W2301 Woodward 2301 governor and basic turbine model Wndtge Wind turbine and turbine control model for GE wind turbines Wndtrb Wind turbine control model 769855665j jb 5/4/2017, 5:12:45 AM STABILIZER MODELS Model Name Description ieeest Power system stabilizer pss2a Dual input Power System Stabilizer (IEEE type PSS 2A) pss2b Dual input Power System Stabilizer (IEEE type PSS 2A) with Voltage Boost signal Transient Stabilizer and Vcutoff wsccst WECC Power System Stabilizer 769855665j jb 5/4/2017, 5:12:45 AM TRANSMISSION DEVICE Model Name Description batt Battery with four quadrant P/Q control and modulation sensitive to frequency and voltage 1tc1 Transformer Load Tap Changer model scgap Series Capacitor Gap Smes1 Controllable current injection model. Can be used to model D-SMES (Distributed Superconducting Magnetic Energy Storage System) of AmericanSuperconductor, etc. stcon Static Synchronous Condenser Stcon1 Core model of a Static Var Compensation Device svcwsc Static Var device (compatible with WSCC Vx/Wx models) tcsc Thyristor controlled series compensation model. upfc Power Flow Controller vft Variable frequency transformer vwscc Static Var device (compatible with WSCC model) 769855665j jb 5/4/2017, 5:12:45 AM LOAD MODELS Model Name Description alwscc Load voltage/frequency dependence model Apfl Pump/fan driven load model for induction motors Blwscc Load voltage/frequency dependence model Cmpld Composite load Motorw Induction machine modeled with rotor flux transients Rect Rectifier-supplied load Sec1d1 Secondary load model with continuous reset of transformer tap ratio Sec1d2 Secondary load model with continuous reset of transformer tap ratio and 3-component characteristic Sec1d3 Secondary load model with continuous reset of transformer tap ratio and 3-component characteristic Spfl Pump/fan driven load model for synchronous motors Wlwscc Pump/fan driven load model for synchronous motors zlwscc Load voltage/frequency dependence model 769855665j jb 5/4/2017, 5:12:45 AM METER MODELS Model Name Description ametr Bus angle recorder. Places bus angle in an output channel fmeta Bus frequency recorder. Places area, zone or all bus frequencies an output channels fmetr Bus frequency recorder. Places bus frequency in an output channel gp1 Generic Generator Protection System gp2 Generic Generator Protection System ifmaz Records MW and MVAR flow on an interface between zones and/or areas ifmon Records MW and MVAR flow on a network interface imetr Branch current recorder. Places branch power and current flow in output channels. monit Dynamic simulation solution monitor (EPC specified model) pmetr Plant total output recorder vmeta Bus voltage recorder. Places all area, zone or system voltages in an output channels. vmetr Bus voltage recorder. Places bus voltage in an output channel. Zvmetr Apparent impedance recorder.places apparent impedance in output channels. Provide the contact person name and telephone number for questions on the Stability data provided. ________________________________________________________________________ 769855665j jb 5/4/2017, 5:12:45 AM C) Short Circuit Study Data GENERATOR DATA FOR SHORT CIRCUIT STUDIES The following information must be provided in its entirety to conduct the short circuit study required as part of the System Impact Study (SIS). Generator Step-up Transformer Information Quantity Description Voltage Ratings of Primary & Secondary Windings Winding Configurations (i.e. Delta, Grounded Wye, etc) MVA Rating Positive Sequence Impedance (R+jX) (Identify if in pu or . If in pu, list base) Zero Sequence Impedance (R+jX) Generator Information Quantity Description Machine Base used for per unit impedances Voltage rating of machine Winding Configuration (ie. Delta, Grounded Wye, etc) Neutral Impedance (If applicable), Ohms Direct-axis Sub-transient Reactance (Xd”), per unit Ohms Quadrature-axis Sub-transient Reactance (X”q), per unit Ohms Direct-axis Transient Reactance (X’d), per unit Ohms Quadrature-axis Transient Reactance (X’q), per unit Ohms Synchronous Reactance (Xs), per unit Ohms Negative Sequence Reactance (X2), per unit Ohms Zero Sequence Reactance (X0), per unit Ohms Note: All values provided above must clearly state if value is in Ohms or per unit Ohms. If the values are provided as per unit values, the base must be provided. Provide the contact person name, telephone number and email for questions on the Short Circuit data provided. 769855665j jb 5/4/2017, 5:12:45 AM This template should be provided back to IID including complete set of data, and signed by the person responsible for all the data provided. Responsible Person Signature: Date: If you have any questions regarding any of the data requested in this template, please call me at (760) 482-3443. Jorge L. Barrientos, P.E. IID System Planning Superintendent 769855665j jb 5/4/2017, 5:12:45 AM