Exponential algorithmic speedup by quantum walk Andrew M. Childs, Richard Cleve, Enrico Deotto,
... the right tree, checking the degree at each step. If we discover that after k steps we are again at a central vertex, we know that the wrong move happened after k/2 steps (k can only be even due to the structure of Gn ) and we can backtrack to that point and take the other edge. After only O(n2 ) st ...
... the right tree, checking the degree at each step. If we discover that after k steps we are again at a central vertex, we know that the wrong move happened after k/2 steps (k can only be even due to the structure of Gn ) and we can backtrack to that point and take the other edge. After only O(n2 ) st ...
The reduced Hamiltonian for next-to-leading-order spin
... PSR J0737-3039A and B [2]. For analysis of the measured GW patterns one has to provide very accurate templates following from theory. This can be achieved by numerical calculations with the matching of functions to the results or directly using analytic tools. In the latter case, waveforms can be ob ...
... PSR J0737-3039A and B [2]. For analysis of the measured GW patterns one has to provide very accurate templates following from theory. This can be achieved by numerical calculations with the matching of functions to the results or directly using analytic tools. In the latter case, waveforms can be ob ...
Multi-particle simulation code for IBS - Indico
... (P.R. Zenkevich, O. Boine-Frenkenheim, A. E. Bolshakov, A new algorithm for the kinetic analysis of inta-beam scattering in storage rings, NIM A, 2005) ...
... (P.R. Zenkevich, O. Boine-Frenkenheim, A. E. Bolshakov, A new algorithm for the kinetic analysis of inta-beam scattering in storage rings, NIM A, 2005) ...
PDF (MRI lecture notes for Letter paper format)
... If, on the other hand, many pushes are delivered in synchrony with the mentioned oscillations of the magnetic needle, even waving a weak magnet can produce strong oscillations of the magnetic needle. This is achieved if the small magnet is moved back and forth at a frequency identical to the natural ...
... If, on the other hand, many pushes are delivered in synchrony with the mentioned oscillations of the magnetic needle, even waving a weak magnet can produce strong oscillations of the magnetic needle. This is achieved if the small magnet is moved back and forth at a frequency identical to the natural ...
Thesis - Archive ouverte UNIGE
... Three theories of gravitation – general relativity, the chameleon and Horava gravity - are confronted with experiment, using standard and adapted post-Newtonian (PN) tools. The laboratory is provided by the Solar System, binary pulsars and future detections at gravitational wave observatories. We te ...
... Three theories of gravitation – general relativity, the chameleon and Horava gravity - are confronted with experiment, using standard and adapted post-Newtonian (PN) tools. The laboratory is provided by the Solar System, binary pulsars and future detections at gravitational wave observatories. We te ...
POLYNOMIAL-TIME ALGORITHMS FOR PRIME FACTORIZATION
... laws of physics. This can be seen in the statement of the quantitative Church's thesis in van Emde Boas [1990], where the word \physical" in the above phrasing is replaced by the word \reasonable." It is dicult to imagine any denition of \reasonable" in this context which does not mean \physically ...
... laws of physics. This can be seen in the statement of the quantitative Church's thesis in van Emde Boas [1990], where the word \physical" in the above phrasing is replaced by the word \reasonable." It is dicult to imagine any denition of \reasonable" in this context which does not mean \physically ...
One and Two Photon Absorption of Atoms and Ions - DORAS
... able elements. In the 1960s synchrotron radiation was pioneered as a suitable photon source [7] for inner shell studies. Although initially limited to measuring photoionization cross sections of noble gases (where one could accurately determine the density in absorption cells) or ions with large ph ...
... able elements. In the 1960s synchrotron radiation was pioneered as a suitable photon source [7] for inner shell studies. Although initially limited to measuring photoionization cross sections of noble gases (where one could accurately determine the density in absorption cells) or ions with large ph ...
hydrodynamics of a rotating strongly interacting fermi gas
... year, who helped my out immensely with my first year classes. Without their patience and help, I would have received far less sleep than I was able to get that year. No discussion about my first year at Duke would be complete without mentioning Dean Hidas and Andrew Dawes. I’ll always remember all t ...
... year, who helped my out immensely with my first year classes. Without their patience and help, I would have received far less sleep than I was able to get that year. No discussion about my first year at Duke would be complete without mentioning Dean Hidas and Andrew Dawes. I’ll always remember all t ...
Measurements of Ultra Strong Magnetic fields in Laser Produced
... This thesis discusses experiments to measure the ultra large magnetic fields generated in the laboratory when a high power laser pulse is focussed onto solid. Two novel techniques to measure these fields have been developed. The experiments were carried out on the femtosecond ASTRA and the picosecon ...
... This thesis discusses experiments to measure the ultra large magnetic fields generated in the laboratory when a high power laser pulse is focussed onto solid. Two novel techniques to measure these fields have been developed. The experiments were carried out on the femtosecond ASTRA and the picosecon ...