• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Faraday`s Law and Joule Heating
Faraday`s Law and Joule Heating

... Measurements next described are done only with the load resistor in place, since there is inconsequential heat-loss for the open-circuit case. Pendulum decay in the open circuit case is due to mechanical friction alone. The increase in the decrement when the load resistor is in place (as is obvious ...
PSpice Orcad Release 9.2 Tutorial Part I
PSpice Orcad Release 9.2 Tutorial Part I

... Bias is a voltage generated across a device or combination of devices. It may be created directly by a voltage source, or indirectly through a combination of sources and other components. Bias analysis refers to the operation of determining this arrangement of voltages. In general, bias analysis is ...
ECE-342 Lab 5: BJT Amplifier Sample Lab Report Don Hummels, Someone Else
ECE-342 Lab 5: BJT Amplifier Sample Lab Report Don Hummels, Someone Else

... Figure 5: Generation of small input signals using a resistor voltage divider. The actual schematic with measured component values is shown on the left, and the Thevenin equivalent of the network is on the right. resistor values used. For all tests, the function generator amplitude was set to provide ...
Precision Instrumentation Amplifier AD524
Precision Instrumentation Amplifier AD524

... www.BDTIC.com/ADI ...
REFURBISHMENT and VERIFICATION of the HEATHKIT TT
REFURBISHMENT and VERIFICATION of the HEATHKIT TT

... Replaced diodes.  The original CR­101 silicon rectifiers are not very rugged, and I  found a couple of bad ones.  Modern 1N4007 diodes are cheap and superior.  I  just clipped one end of the original diode away and bridged the leads with the  new part (Note: the red end of the old diode is the catho ...
The Ideal Transformer Description and Circuit Symbol As with all the
The Ideal Transformer Description and Circuit Symbol As with all the

... bi-directional, so there is nothing inherently “primary” about either of the two windings. The transformer turns ratio in Fig. 1 was indicated on the symbol as “N1:N2.” It could have just as well been labeled “1:n.” In honor of the fact that the ideal transformer is a model for a real transformer, t ...
Dynacorp
Dynacorp

... WARNING: Because of the possible danger to person(s) or property from accidents, which may result from the improper use of products, it is important that correct procedures be followed: Products must be used in accordance with the engineering information specified in the catalog. Proper installation ...
Maharashtra Institute Of Technology, Aurangabad LABORATORY
Maharashtra Institute Of Technology, Aurangabad LABORATORY

TPI TPI 122 Compact Digital Multimeter, ACmV, with boot, test leads
TPI TPI 122 Compact Digital Multimeter, ACmV, with boot, test leads

High-Efficiency 30-A Synchronous Buck SWIFT Converter with Eco
High-Efficiency 30-A Synchronous Buck SWIFT Converter with Eco

... OCL detection threshold setting pin. ITRIP = 10 µA at room temperature, 4700 ppm/°C current is sourced and set the OCL trip voltage as follows: space VOCL = VTRIP/32 ...
Datasheet
Datasheet

Vol. 5, Issue 10, October 2016 Tesla Coil – Double Tuned
Vol. 5, Issue 10, October 2016 Tesla Coil – Double Tuned

... spark gap G is connected across the primary winding which can be triggered at a desired voltage. The primary and secondary coils form two resonance circuits. The primary winding inductance with capacitor C1 and the primary winding resistance element forms a resonant circuit in the primary, the secon ...
PSpice with Orcad 10
PSpice with Orcad 10

... In order for PSpice to simulate your circuit, it must have a “zero” node for a ground. To add this ground, select the Place Ground tool by clicking on the 9th button from the top on the vertical toolbar on the right side. The following dialog box will appear. ...
Short-circuit current rating (SCCR) of industrial control panels
Short-circuit current rating (SCCR) of industrial control panels

138000 Volt Instrument Transformers
138000 Volt Instrument Transformers

... units rated ≥2000A). A bypass protector is provided for all units rated below 1200:5 to protect from transients. The secondary terminals are #10 slotted screws on a short circuiting terminal block located behind a removable cover in the CT base with three (3) 1 ½” NPT conduit hubs. The ground termin ...
Application - Power Factor Correction (PFC) with XMCTM
Application - Power Factor Correction (PFC) with XMCTM

Laboratory Manual for Semiconductor Devices
Laboratory Manual for Semiconductor Devices

... resistor indicates its power handling capacity, not its resistance. The general purpose lab resistor is usually a carbon film type, ¼ watt dissipation. Resistance values are shown via a color coded series of bands for most types, although high precision resistors may have the value printed directly ...
Laboratory Manual - Mohawk Valley Community College
Laboratory Manual - Mohawk Valley Community College

... resistor indicates its power handling capacity, not its resistance. The general purpose lab resistor is usually a carbon film type, ¼ watt dissipation. Resistance values are shown via a color coded series of bands for most types, although high precision resistors may have the value printed directly ...
A High-Accuracy Electronic Pressure Transducer with a Wide
A High-Accuracy Electronic Pressure Transducer with a Wide

... electronic manometer circuit is shown in Fig.6. The circuit is powered from a battery which feeds a 5V regulator, IC1, with a low dropout voltage. The buffer op-amp IC6 is used to generate a -0.5V secondary supply voltage to feed the other op-amps IC4 and IC5 which cannot operate from +5V. The heart ...
www.BDTIC.com/TI Using High-Speed CMOS and Advanced CMOS Logic in Systems With Multiple V
www.BDTIC.com/TI Using High-Speed CMOS and Advanced CMOS Logic in Systems With Multiple V

... in Systems With Multiple VCC Supplies or Partial Power Down CMOS devices offer a designer many desirable features, the most important one being low-power consumption. However, in some systems a designer finds that even the low-power consumption of CMOS is insufficient to meet power supply constraint ...
SP481E 数据资料DataSheet下载
SP481E 数据资料DataSheet下载

... RS-485 allows up to 32 drivers and 32 receivers to be connected to a data bus, making it an ideal choice for multi-drop applications. Since the cabling can be as long as 4,000 feet, RS-485 transceivers are equipped with a wide (-7V to +12V) common mode range to accommodate ground potential differenc ...
Reference Materials - Jefferson Electric
Reference Materials - Jefferson Electric

... is basically a circuit breaker that works only once and then must be replaced. When current exceeds the predetermined current value, a fusible link melts, opening the circuit. When voltage is initially switched on, a large inrush current results, being greatest in the first half-cycle of operation, ...
DS32738741
DS32738741

Laboratory Manual
Laboratory Manual

... resistor indicates its power handling capacity, not its resistance. The general purpose lab resistor is usually a carbon film type, ¼ watt dissipation. Resistance values are shown via a color coded series of bands for most types, although high precision resistors may have the value printed directly ...
Rockwell Automation Allen-Bradley Specification SMC
Rockwell Automation Allen-Bradley Specification SMC

... a.) Only applies during light motor load situations when enabled by user b.) The controller reduces current to the motor and thereby saves energy 3. External Bypass – Optional Run Operation a.) An external bypass contactor may be configured to operate the motor while running at full voltage and spee ...
< 1 ... 204 205 206 207 208 209 210 211 212 ... 1441 >

Current source



A current source is an electronic circuit that delivers or absorbs an electric current which is independent of the voltage across it.A current source is the dual of a voltage source. The term constant-current 'sink' is sometimes used for sources fed from a negative voltage supply. Figure 1 shows the schematic symbol for an ideal current source, driving a resistor load. There are two types - an independent current source (or sink) delivers a constant current. A dependent current source delivers a current which is proportional to some other voltage or current in the circuit.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report