• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Stramski, Dariusz, Marcel Babin, and Slawomir B. Wozniak
Stramski, Dariusz, Marcel Babin, and Slawomir B. Wozniak

Montgomery self-imaging effect using computer
Montgomery self-imaging effect using computer

Automatic cell nuclei counting
Automatic cell nuclei counting

Using the Spectrophotometer
Using the Spectrophotometer

Quantitative determination of chromophore concentrations from 2D
Quantitative determination of chromophore concentrations from 2D

Total Reflection X-Ray Fluorescence Spectrometer
Total Reflection X-Ray Fluorescence Spectrometer

Two-color cross-correlation in small-angle static light
Two-color cross-correlation in small-angle static light

... applications. Sophisticated digital correlators are commercially available, and their use is quite widespread to tackle problems in physics, chemistry, biological science, and medicine. Present day technology makes it possible to record the intensity distribution of a speckle field by means of a cha ...
Fluorescence Quantum Yield Determinations. 9,lO
Fluorescence Quantum Yield Determinations. 9,lO

Characterization of Encircled Flux Source For Multimode
Characterization of Encircled Flux Source For Multimode

... part of several new multimode fiber testing standards. It sets limits for the amount of optical power included within a specified radius of the fiber core. It is intended to create a more reproducible modal condition for multimode fiber testing. Since EF is new, testing sources for EF are not easily ...
Estimation of longitudinal resolution in optical coherence
Estimation of longitudinal resolution in optical coherence

... A general definition of longitudinal resolution accepted in optical coherence imaging is half of the coherence length of the source 共i.e., lcFWHM兾2 or lc兾 2兲.3,13 The choice of the FWHM of 兩␥共␶兲兩 for coherence length, most commonly chosen as mentioned above, is historical in nature and derived from ...
375_Lo.pdf
375_Lo.pdf

... stage controller can simultaneously measure the thickness, mean refractive index, apparent phase retardation and optical axis orientation of a linear birefringence sample. The extraordinary and ordinary refractive indices, therefore, also can be extracted from above parameters if the order and appar ...
Far-Field Optical Superlens
Far-Field Optical Superlens

Heidelberg Retina Tomograph - HRT
Heidelberg Retina Tomograph - HRT

Heuristic Green`s function of the time dependent
Heuristic Green`s function of the time dependent

... out in conditions where the use of the DE is strongly limited (like small volume samples, high absorption and/or low scattering media, short source-receiver distances and early times) could be more easily interpreted. For these reasons the availability of analytical solutions of the RTE would have g ...
Polarimetric imaging of crystals - Werner Kaminsky
Polarimetric imaging of crystals - Werner Kaminsky

... 3.1. Jones calculus A variety of methods have been developed for tracking the polarization state of light as it passes through successive optical elements and complex samples. These are the Poincaré sphere,20 the Mueller calculus,21 and the Jones calculus.22 These tools, and their relative advantag ...
WHITEPAPER Centration Measurement, Alignment
WHITEPAPER Centration Measurement, Alignment

Combining Photonic Crystal and Optical Monte
Combining Photonic Crystal and Optical Monte

... coincidence resolving time (CRT) [1]–[5]. Energy resolution and CRT are limited by insufficient light extraction from the scintillators [6]. If the photons are reflected many times from the scintillator exit face, the path length inside the scintillator This work has received funding from Siemens Me ...
Shaping the focal intensity distribution using spatial coherence
Shaping the focal intensity distribution using spatial coherence

... It is also observed that J1共x兲 / x correlated fields result in a flat-top intensity distribution. Such an intensity distribution could be useful in applications where a uniform intensity spot is required, such as lithography. These intensity distributions, and others, can be roughly predicted using ...
optical coherence tomography
optical coherence tomography

... the scattering potential, extended over the illuminated volume. No structural information will be obtained in this case. At present all OCT techniques use backscattering at u=−p and a wavelength range from, say, l1 to l2 . These techniques give access to a set of Fourier data on the Kz-axis. Hence f ...
Refractive Index and Thickness Analysis of Natural Silicon Dioxide
Refractive Index and Thickness Analysis of Natural Silicon Dioxide

Coherence - Studentportalen
Coherence - Studentportalen

as PDF
as PDF

Optical simulation of phosphor layer of white LEDs
Optical simulation of phosphor layer of white LEDs

NMR and Parity Violation   Anomalous Temperature Dependence in
NMR and Parity Violation Anomalous Temperature Dependence in

... . The temperature dependence of the 1H-MAS spectra of D-alanine from 290K to 220K were shown in Fig.1 by single pulse excitation with a delay time of 4.5 s at a spinning speed of 5 kHz with 256 scans. The results on D-alanine acquired at various temperatures imply that there exists a considerable d ...
Chemistry written examination 1 2008–2011
Chemistry written examination 1 2008–2011

... The volume, in mL, of pure water that must be added to 50.0 mL of 0.0100 M HNO3 to produce a diluted solution of pH 4.00 is closest to A. 50 B. 450 C. 4950 D. 5000 Question 4 The mass, in gram, of one molecule of propanoic acid is A. 74 B. 88 C. 1.2 × 10–22 D. 1.5 × 10–22 Question 5 Aspirin (C 9 H 8 ...
< 1 ... 11 12 13 14 15 16 17 18 19 ... 57 >

Chemical imaging

Chemical imaging (as quantitative – chemical mapping) is the analytical capability to create a visual image of components distribution from simultaneous measurement of spectra and spatial, time information.The main idea - for chemical imaging, the analyst may choose to take as many data spectrum measured at a particular chemical component in spatial location at time; this is useful for chemical identification and quantification. Alternatively, selecting an image plane at a particular data spectrum (PCA - multivariable data of wavelength, spatial location at time) can map the spatial distribution of sample components, provided that their spectral signatures are different at the selected data spectrum.Software for chemical imaging is most specific and distinguished from chemical methods such as chemometrics. Hyperspectral imaging is most often applied to either solid or gel samples, and has applications in chemistry, biology, medicine, pharmacy (see also for example: food science, biotechnology, agriculture and industry. NIR, IR and Raman chemical imaging is also referred to as hyperspectral, spectroscopic, spectral or multispectral imaging (also see microspectroscopy). However, other ultra-sensitive and selective imaging techniques are also in use that involve either UV-visible or fluorescence microspectroscopy. Many imaging techniques can be used to analyze samples of all sizes, from the single molecule to the cellular level in biology and medicine, and to images of planetary systems in astronomy, but different instrumentation is employed for making observations on such widely different systems.Imaging instrumentation has three components: a radiation source to illuminate the sample, a spectrally selective element, and usually a detector array (the camera) to collect the images. When many stacked spectral channels (wavelengths) are collected for different locations of the microspectrometer focus on a line or planar array in the focal plane, the data is called hyperspectral; fewer wavelength data sets are called multispectral. The data format is called a hypercube. The data set may be visualized as a data cube, a three-dimensional block of data spanning two spatial dimensions (x and y), with a series of wavelengths (lambda) making up the third (spectral) axis. The hypercube can be visually and mathematically treated as a series of spectrally resolved images (each image plane corresponding to the image at one wavelength) or a series of spatially resolved spectra. Many materials, both manufactured and naturally occurring, derive their functionality from the spatial distribution of sample components. For example, extended release pharmaceutical formulations can be achieved by using a coating that acts as a barrier layer. The release of active ingredient is controlled by the presence of this barrier, and imperfections in the coating, such as discontinuities, may result in altered performance. In the semi-conductor industry, irregularities or contaminants in silicon wafers or printed micro-circuits can lead to failure of these components. The functionality of biological systems is also dependent upon chemical gradients – a single cell, tissue, and even whole organs function because of the very specific arrangement of components. It has been shown that even small changes in chemical composition and distribution may be an early indicator of disease. Any material that depends on chemical gradients for functionality may be amenable to study by an analytical technique that couples spatial and chemical characterization. To efficiently and effectively design and manufacture such materials, the ‘what’ and the ‘where’ must both be measured. The demand for this type of analysis is increasing as manufactured materials become more complex. Chemical imaging techniques is critical to understanding modern manufactured products and in some cases is a non-destructive technique so that samples are preserved for further testing.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report