• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
60 dB Range (100 nA to 100 µA) ADL5306
60 dB Range (100 nA to 100 µA) ADL5306

... measurement dynamic range in a versatile and easy-to-use form. A single-supply voltage between 3 V and 5.5 V is adequate; dual supplies may optionally be used. Low quiescent current (5 mA typical) permits use in battery-operated applications. IPD, the 100 nA to 100 µA input current applied to the IN ...
Aalborg Universitet Connected Inverter based on Impedance Based Harmonic Analysis
Aalborg Universitet Connected Inverter based on Impedance Based Harmonic Analysis

... kind of harmonic compensation methods have been used in the different topologies [6, 20, 21]. In particular, the most reliable method for harmonic compensation is to increase the gain of the current controller at each harmonic frequency. Hence, only the proportional resonant controller will be consi ...
Electronic Devices and Circuit Theory
Electronic Devices and Circuit Theory

... Upper Saddle River, New Jersey 07458 • All Rights Reserved ...
LT5537 - Wide Dynamic Range RF/IF Log Detector.
LT5537 - Wide Dynamic Range RF/IF Log Detector.

... Note 3: Tests are performed as shown in the configuration of Figure 13. Note 4: Specifications over the –40°C to 85°C temperature range are assured by design, characterization and correlation with statistical process control. Note 5: Operation at lower frequency is possible as described in the “Low ...
BD91364AMUU
BD91364AMUU

... BD91364AMUU has a ripple implanted system at output detection which keeps a normal switching operation even if a low ESR output capacitor is used. This feature also resolved a weakness of a regular hysteresis control, which is, to keep a steady frequency from a variation of frequencies. When operati ...
LM3448 Phase Dimmable Offline LED Driver with
LM3448 Phase Dimmable Offline LED Driver with

BD82061FVJ-LB
BD82061FVJ-LB

... When excessive current flows owing to output shortcircuit or so, ringing occurs by inductance of power source line to IC, and may cause bad influences upon IC actions. In order to avoid this case, connect a bypath capacitor by IN terminal and GND terminal of IC. 1μF or higher is recommended. Pull up ...
Smart sensor II dual-channel 1-bit, 4 MHz, second-order sigma
Smart sensor II dual-channel 1-bit, 4 MHz, second-order sigma

... STPMS2L-PUR: less than 0.5% error over 1:5000 range Precision voltage reference: 1.23 V with programmable TC Internal low drop regulator @ 3 V (typ.) ...
TGP2103 数据资料DataSheet下载
TGP2103 数据资料DataSheet下载

... May 2009 © Rev - ...
TDA1085C Universal Motor Speed Controller
TDA1085C Universal Motor Speed Controller

... associated capacitors into which the a.m. rules have been implemented. Notice the full separation of “Signal World” from “Power”, one by line AB and their communication by a unique strip. These rules will lead to much satisfactory volume production in the sense that speed adjustment will stay valid ...
A Novel Out-of-Step Protection Algorithm Based on Wide Area
A Novel Out-of-Step Protection Algorithm Based on Wide Area

Anatomy of Switching Power Supplies
Anatomy of Switching Power Supplies

... electrolytic capacitor are inversely proportional to the frequency of the input AC voltage: the lower the AC voltage frequency, the bigger the size of those components and vice-versa. Since linear power supplies still use the 60 Hz (or 50 Hz, depending on the country) frequency from the power grid – ...
MiCOM C264 - Elektronický katalog Schneider Electric
MiCOM C264 - Elektronický katalog Schneider Electric

... MODBUS, while its modular design will make it easy to upgrade in line with future advances in communication technology. ...
Ferroresonant Damping Device Solves Amtrak`s Problem
Ferroresonant Damping Device Solves Amtrak`s Problem

... normal steady state operation of the transformer or of the circuit. The FDD self-activates when a circuit breakers opens to de-energize the OCS. In the transient period following a switching activity, the FDD saturates at an instant before the voltage or distribution transformers in the circuit. The ...
R25400 - Zeftronics
R25400 - Zeftronics

... On the ACU the TSL light is off and on the instrument panel, the LV light is on. A Red TSL indicates a grounded Field or field wire. 2. Turn on the Master switch (BAT & ALT only) and observe: that the LV light is Off, on the ACU the TSL is Green. A Red TSL indicates a ground shorted Field. An off TS ...
Direct­current Circuits
Direct­current Circuits

... 2. If R2=R3=2R1 the potential drops over R1 and  R2 are the same I V 3. for any value of R1,R2 and R3 the potential  drop over R1 must be equal to the potential  drop over R2 4. The current through R1 is equal to the  current through R2 plus the current through  R3  (I1=I2+I3) 1) if R2=R3=2R1 then 1 ...
APPLIED ELECTRONICS Outcome 1
APPLIED ELECTRONICS Outcome 1

OPA2832
OPA2832

... product (75MHz) and slew rate (350V/µs), making the OPA2832 an ideal input buffer stage to 3V and 5V CMOS converters. Unlike earlier low-power, single-supply amplifiers, distortion performance improves as the signal swing is decreased. A low 9.3nV/√Hz input voltage noise supports wide dynamic range ...
MAX15058 Evaluation Kit Evaluates: General Description Features
MAX15058 Evaluation Kit Evaluates: General Description Features

... evaluate the MAX15058 high-efficiency, 3A, step-down regulator with integrated switches. The applications include distributed power systems, portable devices, and preregulators. The EV kit is preset for 1.8V output at load currents up to 3A from a 2.8V to 5.5V input supply. The IC features a 1MHz fi ...
APPLIED ELECTRONICS Outcome 1
APPLIED ELECTRONICS Outcome 1

... Input transducers rarely produce sufficient voltage to operate output transducers, (motors, bulbs, etc.) directly. To overcome this problem, we need to AMPLIFY their output voltage or current. Amplifying devices are said to be active components as opposed to non-amplifying components such as resisto ...
Memory Effect Minimization and Wide Instantaneous
Memory Effect Minimization and Wide Instantaneous

Fault Detection in Induction Machine by Application
Fault Detection in Induction Machine by Application

Harmonic Analysis in Electrical Power System with Electric Arc
Harmonic Analysis in Electrical Power System with Electric Arc

... conditions is studied. Simulation result shows the effect of arc furnace model on voltage/current waveform and percentage harmonic component distribution. Index terms: Electric Arc Furnace, Flicker, Furnace modeling. ...
Control characteristics for quasi-optimal operation of switched
Control characteristics for quasi-optimal operation of switched

... SRM with an induction torque meter. The motor was supplied by a converter that enables the independent regulation of all three control variables: phase voltage Uav (by means of the PWM method), switchon angle  on and conduction angle  z . The rotor position angle, and consequently the rotational s ...
TR102 - BGB741L7 for the 2.3GHz to 3.7GHz WiMAX
TR102 - BGB741L7 for the 2.3GHz to 3.7GHz WiMAX

... Due to technical requirements components may contain dangerous substances. For information on the types in question please contact your nearest Infineon Technologies Office. Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infi ...
< 1 ... 524 525 526 527 528 529 530 531 532 ... 1590 >

Power electronics



Power electronics is the application of solid-state electronics to the control and conversion of electric power. It also refers to a subject of research in electronic and electrical engineering which deals with the design, control, computation and integration of nonlinear, time-varying energy-processing electronic systems with fast dynamics.The first high power electronic devices were mercury-arc valves. In modern systems the conversion is performed with semiconductor switching devices such as diodes, thyristors and transistors, pioneered by R. D. Middlebrook and others beginning in the 1950s. In contrast to electronic systems concerned with transmission and processing of signals and data, in power electronics substantial amounts of electrical energy are processed. An AC/DC converter (rectifier) is the most typical power electronics device found in many consumer electronic devices, e.g. television sets, personal computers, battery chargers, etc. The power range is typically from tens of watts to several hundred watts. In industry a common application is the variable speed drive (VSD) that is used to control an induction motor. The power range of VSDs start from a few hundred watts and end at tens of megawatts.The power conversion systems can be classified according to the type of the input and output power AC to DC (rectifier) DC to AC (inverter) DC to DC (DC-to-DC converter) AC to AC (AC-to-AC converter)
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report