XC2301 Series:DATA SHEET
... ●Reference Value : XC2301C51V (fQ0 = fin/1), XC2301C52V (fQ0 = fin/2) (Unless otherwise stated, VDD=3.3V, No Load, Ta=25℃) ...
... ●Reference Value : XC2301C51V (fQ0 = fin/1), XC2301C52V (fQ0 = fin/2) (Unless otherwise stated, VDD=3.3V, No Load, Ta=25℃) ...
voltage-controlled oscillator for fm broadcast radio receiver
... Figure 5 Diode capacitance as a function of reverse voltage; typical values ...
... Figure 5 Diode capacitance as a function of reverse voltage; typical values ...
AN-3004 - Fairchild
... holding current (IH) which is typically 100 µA. At this time, the detector reverts to the "off" (non-conducting) state. The detector may be triggered "on" not only by IFT but also by exceeding the forward blocking voltage between the two main terminals (MT1 and MT2) which is a minimum of 600 volts f ...
... holding current (IH) which is typically 100 µA. At this time, the detector reverts to the "off" (non-conducting) state. The detector may be triggered "on" not only by IFT but also by exceeding the forward blocking voltage between the two main terminals (MT1 and MT2) which is a minimum of 600 volts f ...
SKY65120-21 数据资料DataSheet下载
... parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device. ...
... parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device. ...
Designing a Qi-compliant receiver coil for wireless power systems
... The choice of wire gauge for the Rx coil is based on cost versus performance. Large-diameter wire or bifilar wire (two parallel wires) can provide high efficiencies but is costly and can result in thick Rx-coil designs. For instance, a PCB coil might be cheaper in overall cost but incurs a much high ...
... The choice of wire gauge for the Rx coil is based on cost versus performance. Large-diameter wire or bifilar wire (two parallel wires) can provide high efficiencies but is costly and can result in thick Rx-coil designs. For instance, a PCB coil might be cheaper in overall cost but incurs a much high ...
Using Oscilloscope
... A. Input Coupling For most applications use DC input coupling. This mode is compatible with the standardaccessory, high-impedance probes and it displays logic levels and dc levels of static signals. Use GND input coupling to show where the 0-volt level will be located when you shift to DC or AC coup ...
... A. Input Coupling For most applications use DC input coupling. This mode is compatible with the standardaccessory, high-impedance probes and it displays logic levels and dc levels of static signals. Use GND input coupling to show where the 0-volt level will be located when you shift to DC or AC coup ...
STEPS tutorial
... sampling rate. For more information see the STEPS User Manual. Measurement parameters are set under 'Excitation sine voltage range' (frequency, start and stop values, linear or logarithmic voltage increase, number of steps). The maximum output voltage is recorded in the 'Stop value' field. This is c ...
... sampling rate. For more information see the STEPS User Manual. Measurement parameters are set under 'Excitation sine voltage range' (frequency, start and stop values, linear or logarithmic voltage increase, number of steps). The maximum output voltage is recorded in the 'Stop value' field. This is c ...
CMP0417AAx-E CMOS LPRAM
... 1. tHZ and tOHZ are defined as the time at which the outputs achieve the open circuit conditions and are not referenced to output voltage levels. 2. At any given temperature and voltage condition, tHZ(Max.) is less than tLZ(Min.) both for a given device and from device to device interconnection. 3. ...
... 1. tHZ and tOHZ are defined as the time at which the outputs achieve the open circuit conditions and are not referenced to output voltage levels. 2. At any given temperature and voltage condition, tHZ(Max.) is less than tLZ(Min.) both for a given device and from device to device interconnection. 3. ...
ADI Water Analysis Solution for pH Meters and Conductivity Meters
... using conductivity measurements. In general, the measurement of conductivity is a rapid and inexpensive way of determining the total concentration of ions in a solution. However, it is a nonspecific technique, unable to distinguish between different types of ions, giving instead a reading that is pr ...
... using conductivity measurements. In general, the measurement of conductivity is a rapid and inexpensive way of determining the total concentration of ions in a solution. However, it is a nonspecific technique, unable to distinguish between different types of ions, giving instead a reading that is pr ...
SR100B_E - Innovative Energies
... Components within the power supply responsible for providing the safety barrier between input and output are constructed to provide electrical isolation as required by the relevant standard. However EMI filtering components could be damaged as result of excessively long high voltage tests between in ...
... Components within the power supply responsible for providing the safety barrier between input and output are constructed to provide electrical isolation as required by the relevant standard. However EMI filtering components could be damaged as result of excessively long high voltage tests between in ...
MAX6457–MAX6460 High-Voltage, Low-Current Voltage Monitors in SOT Packages General Description
... ⎝ VREFD ⎠ where VREF = reference output voltage (2.25V, typ), VREFD = divided reference, VTRIP = desired trip threshold in (in volts). For an active-low power-good output, connect the resistor divider R1 and R2 to the inverting input and the reference-divider network to the noninverting input. Alter ...
... ⎝ VREFD ⎠ where VREF = reference output voltage (2.25V, typ), VREFD = divided reference, VTRIP = desired trip threshold in (in volts). For an active-low power-good output, connect the resistor divider R1 and R2 to the inverting input and the reference-divider network to the noninverting input. Alter ...
b. notes E283C2
... Copper (I2R) Losses – Resistive heating losses in the primary and secondary windings of the transformer. Eddy current Losses – resistive heating losses in the core of the transformer. They are proportional to the square of the voltage applied to the transformer. Hysteresis Losses – these are associa ...
... Copper (I2R) Losses – Resistive heating losses in the primary and secondary windings of the transformer. Eddy current Losses – resistive heating losses in the core of the transformer. They are proportional to the square of the voltage applied to the transformer. Hysteresis Losses – these are associa ...
Understanding Ground Loops
... Real grounds are conductors, so there is a certain amount of resistance to Fig. 1: Ground Symbols electrical current between all grounding points. This resistance can change with humidity, temperature, connected equipment and many other variables. The resistance can always allow an electrical voltag ...
... Real grounds are conductors, so there is a certain amount of resistance to Fig. 1: Ground Symbols electrical current between all grounding points. This resistance can change with humidity, temperature, connected equipment and many other variables. The resistance can always allow an electrical voltag ...
TABLE OF CONTENTS
... popular cartridges. All of the adjustments can be made through the access panel on the top of the unit. While the number of switches may at first appear daunting, setting up the Ares is actually quite simple. Figure 4 shows the different switches for setting up the Ares. There are three different ga ...
... popular cartridges. All of the adjustments can be made through the access panel on the top of the unit. While the number of switches may at first appear daunting, setting up the Ares is actually quite simple. Figure 4 shows the different switches for setting up the Ares. There are three different ga ...
ISO150 数据资料 dataSheet 下载
... coupler capable of data rates of 80M Baud, typical. Each channel can be individually programmed to transmit data in either direction. Data is transmitted across the isolation barrier by coupling complementary pulses through high voltage 0.4 pF capacitors. Receiver circuitry restores the pulses to st ...
... coupler capable of data rates of 80M Baud, typical. Each channel can be individually programmed to transmit data in either direction. Data is transmitted across the isolation barrier by coupling complementary pulses through high voltage 0.4 pF capacitors. Receiver circuitry restores the pulses to st ...
unit2
... • An Or-And-Invert (OAI) CMOS gate is similar to the AOI gate except that it is an implementation of product-of-sums realization of a function • The N-tree is implemented as follows: – Each product term is a set of parallel transistors for each input in the term – All product terms (parallel groups) ...
... • An Or-And-Invert (OAI) CMOS gate is similar to the AOI gate except that it is an implementation of product-of-sums realization of a function • The N-tree is implemented as follows: – Each product term is a set of parallel transistors for each input in the term – All product terms (parallel groups) ...
BD9536FV
... transistor. The IC also incorporates a new technology called H Reg , a Rohm proprietary control method which facilitates ultra-high transient response against changes in load. For protection and ease of use, the IC also incorporates soft start, variable frequency, and short circuit protection with t ...
... transistor. The IC also incorporates a new technology called H Reg , a Rohm proprietary control method which facilitates ultra-high transient response against changes in load. For protection and ease of use, the IC also incorporates soft start, variable frequency, and short circuit protection with t ...
XF1001-SC
... App Note [1] Biasing - The XF1001-SC requires power supply sequencing. Negative voltage supply (Vgg) needs to be turned on first and then positive voltage can be applied to the drain (Vdd). When turning off the device, the positive supply (Vdd) should be turned off first and then negative voltage (V ...
... App Note [1] Biasing - The XF1001-SC requires power supply sequencing. Negative voltage supply (Vgg) needs to be turned on first and then positive voltage can be applied to the drain (Vdd). When turning off the device, the positive supply (Vdd) should be turned off first and then negative voltage (V ...
Unit 1 QN Questions Marks Unit No. BLOOMS Level (1
... required signal conditioning so that each of these can be connected to the DAS and so that the indicated variable range corresponds to 00H to FFH. Specify the resolution of each in terms of the change in each variable that corresponds to an LSB change in the ADC output. 24. A digital control systems ...
... required signal conditioning so that each of these can be connected to the DAS and so that the indicated variable range corresponds to 00H to FFH. Specify the resolution of each in terms of the change in each variable that corresponds to an LSB change in the ADC output. 24. A digital control systems ...
Power electronics
Power electronics is the application of solid-state electronics to the control and conversion of electric power. It also refers to a subject of research in electronic and electrical engineering which deals with the design, control, computation and integration of nonlinear, time-varying energy-processing electronic systems with fast dynamics.The first high power electronic devices were mercury-arc valves. In modern systems the conversion is performed with semiconductor switching devices such as diodes, thyristors and transistors, pioneered by R. D. Middlebrook and others beginning in the 1950s. In contrast to electronic systems concerned with transmission and processing of signals and data, in power electronics substantial amounts of electrical energy are processed. An AC/DC converter (rectifier) is the most typical power electronics device found in many consumer electronic devices, e.g. television sets, personal computers, battery chargers, etc. The power range is typically from tens of watts to several hundred watts. In industry a common application is the variable speed drive (VSD) that is used to control an induction motor. The power range of VSDs start from a few hundred watts and end at tens of megawatts.The power conversion systems can be classified according to the type of the input and output power AC to DC (rectifier) DC to AC (inverter) DC to DC (DC-to-DC converter) AC to AC (AC-to-AC converter)