• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
GAC 2.0 ANALOG GALVANOMETER CONTROLLER OPERATOR`S
GAC 2.0 ANALOG GALVANOMETER CONTROLLER OPERATOR`S

... when the motor accelerates then draws very little current at constant position or constant velocity. The current peaks can be as high as ± 8 amps for a few milliseconds, but ± 4 amps for one millisecond are more typical. The required RMS current rarely exceeds 4 amps but the supply(s) must be capabl ...
575A - Ortec
575A - Ortec

... Allow the instrument to dry completely before reconnecting it to the power source. ...
ADM1073 数据手册DataSheet 下载
ADM1073 数据手册DataSheet 下载

... Analog Pin for Soft Start. An external capacitor on this pin sets the ramp rate of the inrush current profile. This pin can be overdriven to alter the current limit control loop threshold. Voltage Input from External Sense Resistor. Ground Supply to Chip (usually a −48 V system supply). Also low-sid ...
Measurement and Error - Gopalan College of Engineering
Measurement and Error - Gopalan College of Engineering

... 5. Many measurements can be carried either simultaneously or in rapid succession. 6. Electronic circuits can detect and amplify very weak signals and can measure the events of very short duration as well. 7. Electronic measurement makes possible to build analog and digital signals. The digital signa ...
EASY2504 / IEC 61131 + CANopen Master / Slave - frenzel
EASY2504 / IEC 61131 + CANopen Master / Slave - frenzel

... The EASY2504 is an all round very high performance automation system for industrial applications. It is based on the powerful CoDeSys run time system, with several library extensions and enhancements. Furthermore a CANopen run time system is implemented. The system can be configured to run either in ...
ADuM3100 数据手册DataSheet下载
ADuM3100 数据手册DataSheet下载

... All voltages are relative to their respective ground. 5 V/3 V operation: 4.5 V ≤ VDD1 ≤ 5.5 V, 3.0 V ≤ VDD2 ≤ 3.6 V. 3 V/5 V operation: 3.0 V ≤ VDD1 ≤ 3.6 V, 4.5 V ≤ VDD2 ≤ 5.5 V. All minimum/maximum specifications apply over the entire recommended operation range, unless otherwise noted. All typica ...
Power Supplies
Power Supplies

... The SDN Series standard options allow for operation in a wide variety of applications. With the addition of an external redundancy module, the SDN can also be used for true redundant operation including 2N and N+x configurations. All SDN units include built in current sharing for parallel and redund ...
DSS60601MZ4 Features Mechanical Data
DSS60601MZ4 Features Mechanical Data

... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
GHTU MPas of V2.6
GHTU MPas of V2.6

... Enter the humidity value at which the output should have 4mA (respectively 0V). 4. Choose the desired value by pressing 2 (down) or 3 (up) key. Max. input range: 0.0...100.0 % (ex works: 0.0%) 5. Enter by pressing key 1 (SET), select next parameter: 'Out.1' without temperature arrow appears in the d ...
PDF
PDF

... transistors of the pull down network to control the PMOS keeper transistor,yielding reduction of the contention between keeper transistor and the pull down network from which previously proposed techniques have suffered. Moreover, using the stacking effect, leakage current is reduced and the perform ...
Weighing Applications for Hazardous Areas
Weighing Applications for Hazardous Areas

... extremely expensive. The main purpose of the surge protection barrier is to limit induced transient voltages across sensitive electrical equipment and to safely divert the surge current to ground. The surge protection barrier incorporates the line to line (differential mode) and line to earth (commo ...
Controller-based system for interfacing selector-less
Controller-based system for interfacing selector-less

... present a multi-port technique for reading accurate analogue cross-point resistance values from devices within a planar, selector-less crossbar array - a markedly stricter criterion than achieving a good digital read margin. We implement the nonintrusive reading and writing techniques on a desktop P ...
MAX481 DS - Part Number Search
MAX481 DS - Part Number Search

S-Parameters and Related Quantities
S-Parameters and Related Quantities

Symmetra PX Guide Specifications
Symmetra PX Guide Specifications

... or less at full system, while providing conditioned power to the critical load bus, and charging the batteries under steady-state operating conditions. This shall be true while supporting loads of both a linear or non-linear type. This shall be accomplished with no additional filters, magnetic devic ...
MAX9234/MAX9236/ MAX9238 Hot-Swappable, 21-Bit, DC-Balanced LVDS Deserializers
MAX9234/MAX9236/ MAX9238 Hot-Swappable, 21-Bit, DC-Balanced LVDS Deserializers

... the imbalance of ones and zeros transmitted on each channel. If +1 is assigned to each binary 1 transmitted and -1 is assigned to each binary 0 transmitted, the variation in the running sum of assigned values is called the digital sum variation (DSV). The maximum DSV for the data channels is 10. At ...
UNIT – III Induction Motor Drives
UNIT – III Induction Motor Drives

Starting and control of three-phase asynchronous motors
Starting and control of three-phase asynchronous motors

... solution, as high peak currents influence the electrical supply, and torque surges subject the mechanical components of the machine or system to high levels of stress. The soft starter provides a remedy. It enables a continuous and surge-free increase in torque and also offers the opportunity for a ...
Solid-State Relays Current Limit Performance
Solid-State Relays Current Limit Performance

AD8007
AD8007

... In single-supply operation, with RL referenced to VS, worst case is V VOUT = S ...
Dynamic Characteristics of Mho Distance Relays
Dynamic Characteristics of Mho Distance Relays

AN4304 Application note Introduction
AN4304 Application note Introduction

... signals may be demodulated by the current sensing device, resulting in an error in the current measurement. Consequently, for power supply and DCDC converter applications, it is necessary to filter the input path of the current sensing to improve the accuracy of the measurement. Such filters must be ...
ZA013563570
ZA013563570

... In the traditional form of FM the carrier frequency is changed or modulated by the amplitude of the analog signal. In a fiber optic system, this is not feasible since both are light sources, the LED and the LASER, are fixed frequency devices. In fiber optic systems, FM is achieved by using the origi ...
LT1801/LT1802 - Dual/Quad 80MHz, 25V/µs Low Power Rail-to-Rail Input and Output Precision Op Amps
LT1801/LT1802 - Dual/Quad 80MHz, 25V/µs Low Power Rail-to-Rail Input and Output Precision Op Amps

... Typically, the LT1801/LT1802 have an input offset voltage of less than 100μV, an input bias current of less than 50nA and an open-loop gain of 85 thousand. The LT1801/LT1802 have an input range that includes both supply rails and an output that swings within 20mV of either supply rail to maximize th ...
AN2007-04
AN2007-04

... Providing dead time can on one side avoid bridge shoot through but on the other side it has also adverse effect. To clarify the effect of dead time, let’s consider one leg of the voltage source inverter as shown in Figure. 2. Assuming first that output current flows in direction shown on the illustr ...
< 1 ... 436 437 438 439 440 441 442 443 444 ... 1590 >

Power electronics



Power electronics is the application of solid-state electronics to the control and conversion of electric power. It also refers to a subject of research in electronic and electrical engineering which deals with the design, control, computation and integration of nonlinear, time-varying energy-processing electronic systems with fast dynamics.The first high power electronic devices were mercury-arc valves. In modern systems the conversion is performed with semiconductor switching devices such as diodes, thyristors and transistors, pioneered by R. D. Middlebrook and others beginning in the 1950s. In contrast to electronic systems concerned with transmission and processing of signals and data, in power electronics substantial amounts of electrical energy are processed. An AC/DC converter (rectifier) is the most typical power electronics device found in many consumer electronic devices, e.g. television sets, personal computers, battery chargers, etc. The power range is typically from tens of watts to several hundred watts. In industry a common application is the variable speed drive (VSD) that is used to control an induction motor. The power range of VSDs start from a few hundred watts and end at tens of megawatts.The power conversion systems can be classified according to the type of the input and output power AC to DC (rectifier) DC to AC (inverter) DC to DC (DC-to-DC converter) AC to AC (AC-to-AC converter)
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report