MAX8791/MAX8791B Single-Phase, Synchronous MOSFET Drivers General Description Features
... threshold is relatively constant, with only a minor dependence on the input voltage due to the typically low duty cycles. The switching waveforms may appear noisy and asynchronous when light loading activates the pulse-skipping operation, but this is a normal operating condition that results in high ...
... threshold is relatively constant, with only a minor dependence on the input voltage due to the typically low duty cycles. The switching waveforms may appear noisy and asynchronous when light loading activates the pulse-skipping operation, but this is a normal operating condition that results in high ...
UM6K33N
... No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products" ...
... No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products" ...
Dear Valued Customer, We are honored that you chose the P1 Dual
... 1.3 Voltage input impedance loading: helpful guidance from your P1 Manufacturers often specify a recommended loading value or range that best matches their cartridge. This is the optimal impedance that should electrically load the cartridge. If an impedance of that value is simply added in parallel ...
... 1.3 Voltage input impedance loading: helpful guidance from your P1 Manufacturers often specify a recommended loading value or range that best matches their cartridge. This is the optimal impedance that should electrically load the cartridge. If an impedance of that value is simply added in parallel ...
electrically isolated system response to rapid charging events using
... discharge current of 5A, and keeper potential of 26.6V. Figure 5 shows the current supplied by the high voltage power supply reaches its steady state value in approximately 255ms. The current was set to 33mA, but an analysis of figure 5 reveals the average current during the beam firing of 30.6mA. I ...
... discharge current of 5A, and keeper potential of 26.6V. Figure 5 shows the current supplied by the high voltage power supply reaches its steady state value in approximately 255ms. The current was set to 33mA, but an analysis of figure 5 reveals the average current during the beam firing of 30.6mA. I ...
GE 6A Digital PicoDLynx : Non-Isolated DC-DC Power Modules Data Sheet
... Output Ripple and Noise on nominal output (VIN=VIN, nom and IO=IO, min to IO, max Co = 0.1μF // 22 μF ceramic ...
... Output Ripple and Noise on nominal output (VIN=VIN, nom and IO=IO, min to IO, max Co = 0.1μF // 22 μF ceramic ...
Film Capacitors - Power Factor Correction - MKK480-D-20
... In case of the presence of harmonics installation of a de-tuned capacitor bank (reactors) must be considered. Check the discharge resistors/reactors and in case of doubt, check their function: (1) Power the capacitor up and down. (2) After 90 seconds the voltage between the terminals must decl ...
... In case of the presence of harmonics installation of a de-tuned capacitor bank (reactors) must be considered. Check the discharge resistors/reactors and in case of doubt, check their function: (1) Power the capacitor up and down. (2) After 90 seconds the voltage between the terminals must decl ...
353/355 Users Manual
... Remove test leads from the Meter before opening the Meter case. Never operate the Meter with the back cover removed or the case open. Never remove the back cover or open the case of an instrument without first removing the test leads or the jaws from a live conductor. Use caution when working with v ...
... Remove test leads from the Meter before opening the Meter case. Never operate the Meter with the back cover removed or the case open. Never remove the back cover or open the case of an instrument without first removing the test leads or the jaws from a live conductor. Use caution when working with v ...
Synery Operation Manual
... If the units are to be operated in an environment where the airflow is restricted such as sealed racks, the cooling should be supplemented by extra cooling fans to evacuate the heated air and aid the flow of cool air through the unit. ...
... If the units are to be operated in an environment where the airflow is restricted such as sealed racks, the cooling should be supplemented by extra cooling fans to evacuate the heated air and aid the flow of cool air through the unit. ...
MKK525-D-20-02 - B25673A5202A020
... In case of the presence of harmonics installation of a de-tuned capacitor bank (reactors) must be considered. Check the discharge resistors/reactors and in case of doubt, check their function: (1) Power the capacitor up and down. (2) After 90 seconds the voltage between the terminals must decl ...
... In case of the presence of harmonics installation of a de-tuned capacitor bank (reactors) must be considered. Check the discharge resistors/reactors and in case of doubt, check their function: (1) Power the capacitor up and down. (2) After 90 seconds the voltage between the terminals must decl ...
Keysight 1GC1-4268 DC - 12 GHz Packaged Divide-by
... Independent of the bias applied to the package, the backside of the package should always be connected to both a good RF ground plane and a good thermal heat sinking region on the PC–board to optimize performance. For single–ended output operation, the unused RF output pin should be terminated into ...
... Independent of the bias applied to the package, the backside of the package should always be connected to both a good RF ground plane and a good thermal heat sinking region on the PC–board to optimize performance. For single–ended output operation, the unused RF output pin should be terminated into ...
Design Challenges in Backlighting LCD TVs
... are actually electronically controlled light valves that require a backlight source in order to produce a visible image. LCD TVs typically use cold-cathode fluorescent lamps (CCFLs) for this purpose. Other technologies such as light-emitting diodes (LEDs) are being considered, but high cost has limit ...
... are actually electronically controlled light valves that require a backlight source in order to produce a visible image. LCD TVs typically use cold-cathode fluorescent lamps (CCFLs) for this purpose. Other technologies such as light-emitting diodes (LEDs) are being considered, but high cost has limit ...
Film Capacitors - Power Factor Correction - MKK415-D-20
... In case of the presence of harmonics installation of a de-tuned capacitor bank (reactors) must be considered. Check the discharge resistors/reactors and in case of doubt, check their function: (1) Power the capacitor up and down. (2) After 90 seconds the voltage between the terminals must decl ...
... In case of the presence of harmonics installation of a de-tuned capacitor bank (reactors) must be considered. Check the discharge resistors/reactors and in case of doubt, check their function: (1) Power the capacitor up and down. (2) After 90 seconds the voltage between the terminals must decl ...
Film Capacitors - Power Factor Correction - MKK440-D-30
... In case of the presence of harmonics installation of a de-tuned capacitor bank (reactors) must be considered. Check the discharge resistors/reactors and in case of doubt, check their function: (1) Power the capacitor up and down. (2) After 90 seconds the voltage between the terminals must decl ...
... In case of the presence of harmonics installation of a de-tuned capacitor bank (reactors) must be considered. Check the discharge resistors/reactors and in case of doubt, check their function: (1) Power the capacitor up and down. (2) After 90 seconds the voltage between the terminals must decl ...
Lamp Operation Basics
... THD refers to Total Harmonic Distortion. Harmonic distortion is present with most electrical equipment. THD is the measurement of the distortion created from the equipment’s current draw. True resistive loads, such as an incandescent light bulb, do not have THD. Equipment that contains switch mode p ...
... THD refers to Total Harmonic Distortion. Harmonic distortion is present with most electrical equipment. THD is the measurement of the distortion created from the equipment’s current draw. True resistive loads, such as an incandescent light bulb, do not have THD. Equipment that contains switch mode p ...
AD7873
... The AD7873 features direct battery measurement, temperature measurement, and touch pressure measurement. The AD7873 also has an on-board reference of 2.5 V that can be used for the auxiliary input, battery monitor, and temperature measurement modes. When not in use, the internal reference can be shu ...
... The AD7873 features direct battery measurement, temperature measurement, and touch pressure measurement. The AD7873 also has an on-board reference of 2.5 V that can be used for the auxiliary input, battery monitor, and temperature measurement modes. When not in use, the internal reference can be shu ...
DEVINE Spec Submittal
... i. Within rated capacity, dimmers shall be available for direct control of incandescent, halogen, magnetic low voltage, electronic low voltage, and fluorescent. Matching fan-speed controls shall also be available. j. Controls shall be capable of operating at the rated capacity; this includes modifie ...
... i. Within rated capacity, dimmers shall be available for direct control of incandescent, halogen, magnetic low voltage, electronic low voltage, and fluorescent. Matching fan-speed controls shall also be available. j. Controls shall be capable of operating at the rated capacity; this includes modifie ...
Film Capacitors - Power Factor Correction - MKK525-D-20
... In case of the presence of harmonics installation of a de-tuned capacitor bank (reactors) must be considered. Check the discharge resistors/reactors and in case of doubt, check their function: (1) Power the capacitor up and down. (2) After 90 seconds the voltage between the terminals must decl ...
... In case of the presence of harmonics installation of a de-tuned capacitor bank (reactors) must be considered. Check the discharge resistors/reactors and in case of doubt, check their function: (1) Power the capacitor up and down. (2) After 90 seconds the voltage between the terminals must decl ...
Circuit Note CN-0214
... First, the voltage measured between the two wires of the thermocouple (V1). The RTD voltage is measured, converted to a temperature via a lookup table and this temperature is then converted to it’s equivalent thermocouple voltage (V2). V1 and V2 are then added to give the overall thermocouple voltag ...
... First, the voltage measured between the two wires of the thermocouple (V1). The RTD voltage is measured, converted to a temperature via a lookup table and this temperature is then converted to it’s equivalent thermocouple voltage (V2). V1 and V2 are then added to give the overall thermocouple voltag ...