
ics85104i.pdf
... Pd_total = Total Device Power Dissipation (example calculation is in Section 1 above) TA = Ambient Temperature In order to calculate junction temperature, the appropriate junction-to-ambient thermal resistance θJA must be used. Assuming no air flow and a multi-layer board, the appropriate value is 9 ...
... Pd_total = Total Device Power Dissipation (example calculation is in Section 1 above) TA = Ambient Temperature In order to calculate junction temperature, the appropriate junction-to-ambient thermal resistance θJA must be used. Assuming no air flow and a multi-layer board, the appropriate value is 9 ...
SmartWire-DT The System
... All information in this manual was provided by us to the best of our knowledge and belief and in accordance with the current state-of-the-art. However, inaccuracies cannot be totally excluded, and we therefore do not assume any liability for the accuracy or completeness of this information. This inf ...
... All information in this manual was provided by us to the best of our knowledge and belief and in accordance with the current state-of-the-art. However, inaccuracies cannot be totally excluded, and we therefore do not assume any liability for the accuracy or completeness of this information. This inf ...
a comparative analysis of different cmos logic design techniques for
... achieve more and more functionality at higher speed and low power, keeping area and cost low. Circuit design techniques also plays an important role in achieving high performance, low power or low area. Design engineers can consider different logic design techniques according to the need of their de ...
... achieve more and more functionality at higher speed and low power, keeping area and cost low. Circuit design techniques also plays an important role in achieving high performance, low power or low area. Design engineers can consider different logic design techniques according to the need of their de ...
01/04/2010 716KB - AMETEK Programmable Power
... No, this is NOT an indication of a problem. The front panel switch on DHP 2 kW & 3 kW power supplies is a soft enable/disable shutdown and not a circuit breaker. If the input power to the DHP 2 kW & 3 kW is not removed by an external contactor or circuit breaker portions of the internal circuitry re ...
... No, this is NOT an indication of a problem. The front panel switch on DHP 2 kW & 3 kW power supplies is a soft enable/disable shutdown and not a circuit breaker. If the input power to the DHP 2 kW & 3 kW is not removed by an external contactor or circuit breaker portions of the internal circuitry re ...
NPCC Glossary - Northeast Power Coordinating Council
... Cable — An underground or underwater circuit. C-13 Capability, Operating — The maximum load carrying ability of generating equipment or other electrical apparatus under specified conditions for a given time interval. C-1 Capacity — The rated continuous load-carrying ability, expressed in megawatts ( ...
... Cable — An underground or underwater circuit. C-13 Capability, Operating — The maximum load carrying ability of generating equipment or other electrical apparatus under specified conditions for a given time interval. C-1 Capacity — The rated continuous load-carrying ability, expressed in megawatts ( ...
1.0 overcurrent protection
... Virtual Control Switches (43/101) The relay shall include 4 virtual selector switches (x43) and one virtual breaker control switch (101), controllable from both the HMI and communication ports. Relay Logic The relay shall include programmable logic for each output, for all inputs, and at least ten a ...
... Virtual Control Switches (43/101) The relay shall include 4 virtual selector switches (x43) and one virtual breaker control switch (101), controllable from both the HMI and communication ports. Relay Logic The relay shall include programmable logic for each output, for all inputs, and at least ten a ...
Mini-SAM II Layout - Simon
... (7) Trigger Inputs can be set via jumper for high or low or isolated high or low side triggering. Each input has a series limiting resistor of 4.7KΩ 1/4W and the typical isolator diode Vf = 1.15V. The current in the diode is the Idiode (mA) = (Vpullup – 1.15)/4.7 This current must always be set for ...
... (7) Trigger Inputs can be set via jumper for high or low or isolated high or low side triggering. Each input has a series limiting resistor of 4.7KΩ 1/4W and the typical isolator diode Vf = 1.15V. The current in the diode is the Idiode (mA) = (Vpullup – 1.15)/4.7 This current must always be set for ...
Charge Pump Flash LED Driver
... the cathode(s) of the LED package and a low resistance sense resistor (typically 1.25Ω). The ISET pin monitors the voltage at the cathode and signals the charge pump to increase or decrease the output current until the ISET voltage reaches the programmed setting. The resistor value is chosen to ...
... the cathode(s) of the LED package and a low resistance sense resistor (typically 1.25Ω). The ISET pin monitors the voltage at the cathode and signals the charge pump to increase or decrease the output current until the ISET voltage reaches the programmed setting. The resistor value is chosen to ...
AD7783 数据手册DataSheet下载
... be obtained. The part operates from a single 3 V or 5 V supply. When operating from 3 V supplies, the power dissipation for the part is 3.9 mW. The AD7783 is available in a 16-lead TSSOP. Another part in the AD778x family is the AD7782. It is similar to the AD7783 except it has no integrated current ...
... be obtained. The part operates from a single 3 V or 5 V supply. When operating from 3 V supplies, the power dissipation for the part is 3.9 mW. The AD7783 is available in a 16-lead TSSOP. Another part in the AD778x family is the AD7782. It is similar to the AD7783 except it has no integrated current ...
PPT: The 607 Standard
... ANSI TIA 607B covers grounding and bonding for telecommunications Canadian Electrical Code ...
... ANSI TIA 607B covers grounding and bonding for telecommunications Canadian Electrical Code ...
MELF Resistors - Token Components
... The RFM speciality series of high frequency non-inductance MELF resistor from Token Electronics has been extended to offer more than GHz operation, making the devices more suitable for high frequency RF applications. They are the perfect choice in high frequency circuit designs where the parasitic i ...
... The RFM speciality series of high frequency non-inductance MELF resistor from Token Electronics has been extended to offer more than GHz operation, making the devices more suitable for high frequency RF applications. They are the perfect choice in high frequency circuit designs where the parasitic i ...
BASIC MATHEMATICS FOR ELECTRICITY
... Note that for every increase of one in the power of 10, the decimal point moves one place to the right. For 0, 1, 2, 3, etc., the power is equal to the number of zeros. ...
... Note that for every increase of one in the power of 10, the decimal point moves one place to the right. For 0, 1, 2, 3, etc., the power is equal to the number of zeros. ...
AN113 - Power Conversion, Measurement and Pulse Circuits
... output. Feedback to the regulator stabilizes the loop and the RC at the VC pin provides frequency compensation. The 100k path from L1 bootstraps Q1’s gate drive to about 10V, ensuring saturation.3 The output connected 300Ω-diode combination provides short-circuit protection by shutting down the LT11 ...
... output. Feedback to the regulator stabilizes the loop and the RC at the VC pin provides frequency compensation. The 100k path from L1 bootstraps Q1’s gate drive to about 10V, ensuring saturation.3 The output connected 300Ω-diode combination provides short-circuit protection by shutting down the LT11 ...
A Closed-Loop, Wideband, 100A Active Load
... testing the regulator and associated components under such transient loading conditions. To meet this need, a closed-loop, 500kHz bandwidth, linearly responding, 100A capacity active load is described below. ...
... testing the regulator and associated components under such transient loading conditions. To meet this need, a closed-loop, 500kHz bandwidth, linearly responding, 100A capacity active load is described below. ...
Variable Frequency Drives for conveyor starting
... less controlled manner. A fluid coupling works on the principle of creating a mechanical slip between the motor and the driven load. The motor still provides its normal high starting torque and high starting current. Instead of applying the torque directly to the load though, it is applied to the in ...
... less controlled manner. A fluid coupling works on the principle of creating a mechanical slip between the motor and the driven load. The motor still provides its normal high starting torque and high starting current. Instead of applying the torque directly to the load though, it is applied to the in ...
ADS7835 数据资料 dataSheet 下载
... The internal reference is connected to the VREF pin and to the internal buffer via a 10kΩ series resistor. Thus, the reference voltage can easily be overdriven by an external reference voltage. The voltage range for the external voltage is 2.3V to 2.9V, corresponding to an analog input range of 2.3V ...
... The internal reference is connected to the VREF pin and to the internal buffer via a 10kΩ series resistor. Thus, the reference voltage can easily be overdriven by an external reference voltage. The voltage range for the external voltage is 2.3V to 2.9V, corresponding to an analog input range of 2.3V ...