
16-Bit 1 MSPS PulSAR Unipolar ADC with Reference AD7667
... When SER/PAR is HIGH, this input, part of the serial port, is used as a digital select input for choosing the internal data clock or an external data clock. With EXT/INT tied LOW, the internal clock is selected on the SCLK output. With EXT/INT set to a logic HIGH, output data is synchronized to an e ...
... When SER/PAR is HIGH, this input, part of the serial port, is used as a digital select input for choosing the internal data clock or an external data clock. With EXT/INT tied LOW, the internal clock is selected on the SCLK output. With EXT/INT set to a logic HIGH, output data is synchronized to an e ...
DC Machines
... saturated). Because flux increases with load, speed must drop in order to maintain the balance between impressed voltage and counter emf; moreover, the increase in armature current caused by increased torque is smaller than in the shunt motor because of the increased flux. The series motor is theref ...
... saturated). Because flux increases with load, speed must drop in order to maintain the balance between impressed voltage and counter emf; moreover, the increase in armature current caused by increased torque is smaller than in the shunt motor because of the increased flux. The series motor is theref ...
Understanding and Configuring the 1
... The internal time base of 1-Wire slaves can vary from 15µs to 60µs. Therefore, a slave device that responds with a 0 can stop pulling the line low as soon as 15µs after it recognizes the beginning of the time slot. With a slew-rate setting of 1.37V/µs (nominal value), the slave might recognize the t ...
... The internal time base of 1-Wire slaves can vary from 15µs to 60µs. Therefore, a slave device that responds with a 0 can stop pulling the line low as soon as 15µs after it recognizes the beginning of the time slot. With a slew-rate setting of 1.37V/µs (nominal value), the slave might recognize the t ...
1 Purpose - OATi Oasis
... negotiations a determination will be made as to which facilities impact OUC’s transmission, and which do not. The specifications listed in this document are the same requirements that OUC facilities meet or exceed. During studies and technical review no preference is made between OUC and non-OUC fac ...
... negotiations a determination will be made as to which facilities impact OUC’s transmission, and which do not. The specifications listed in this document are the same requirements that OUC facilities meet or exceed. During studies and technical review no preference is made between OUC and non-OUC fac ...
$doc.title
... Continuous current through each VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±200 mA Output high sink current, ISK (VO = 5.5 V and VCC CABLE = 3 V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 mA Package thermal impedance, θJA ...
... Continuous current through each VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±200 mA Output high sink current, ISK (VO = 5.5 V and VCC CABLE = 3 V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 mA Package thermal impedance, θJA ...
Making Magnetron Sputtering Work: Reversing the Glow to Arc
... deposition methods exist, virtually all requiring external power (energy) of some type: typically electrical, but perhaps thermal or chemical in some cases. Evaporation-based deposition uses heating elements or electron beams to raise the temperature and hence vapor pressure of the material to be de ...
... deposition methods exist, virtually all requiring external power (energy) of some type: typically electrical, but perhaps thermal or chemical in some cases. Evaporation-based deposition uses heating elements or electron beams to raise the temperature and hence vapor pressure of the material to be de ...
2 Faults, types and effects 2.1 The development of simple distribution systems
... fault current is only limited by the inherent (natural) series impedance of the power system up to the point of fault (Ohm’s law). By design, this inherent series impedance in a power system is purposely chosen to be as low as possible in order to get maximum power transfer to the consumer so that u ...
... fault current is only limited by the inherent (natural) series impedance of the power system up to the point of fault (Ohm’s law). By design, this inherent series impedance in a power system is purposely chosen to be as low as possible in order to get maximum power transfer to the consumer so that u ...
08. Operating Guide and Planning Guide Revisions
... (4) With any single Generation Resource unavailable, and with any other generation preemptively redispatched, the contingency loss of a single Transmission Facility (either without a fault or subsequent to a normallycleared non-three-phase fault) with all other facilities normal should not cause the ...
... (4) With any single Generation Resource unavailable, and with any other generation preemptively redispatched, the contingency loss of a single Transmission Facility (either without a fault or subsequent to a normallycleared non-three-phase fault) with all other facilities normal should not cause the ...
Table of Contents
... with less than 60W exciter drive. In addition, it has automatic antenna impedance matching capability for loads up to 3:1 VSWR (2:1 on 160 meters). It features a Remote Control Unit (RCU), contains nonvolatile memory for settings on up to ten different antennas per frequency segment, and offers comm ...
... with less than 60W exciter drive. In addition, it has automatic antenna impedance matching capability for loads up to 3:1 VSWR (2:1 on 160 meters). It features a Remote Control Unit (RCU), contains nonvolatile memory for settings on up to ten different antennas per frequency segment, and offers comm ...
128K x 24 Bit Static Random Access Memory MCM6341
... the suitability of its products for any particular purpose, nor does Motorola assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation consequential or incidental damages. “Typical” parameters ...
... the suitability of its products for any particular purpose, nor does Motorola assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation consequential or incidental damages. “Typical” parameters ...
WFPS1 WIND FARM POWER STATION GRID CODE PROVISIONS
... Frequency changes, shall be achieved by proportionately altering the Active Power output of all available WTG as opposed to switching individual WTG on or off, in so far as possible. WFPS1.5.2.2.9 The Frequency Response System shall respond to Frequency changes as close to real-time as possible. The ...
... Frequency changes, shall be achieved by proportionately altering the Active Power output of all available WTG as opposed to switching individual WTG on or off, in so far as possible. WFPS1.5.2.2.9 The Frequency Response System shall respond to Frequency changes as close to real-time as possible. The ...
LME49720 数据资料 dataSheet 下载
... inputs changes the amplifier’s noise gain. The result is that the error signal (distortion) is amplified by a factor of 101. Although the amplifier’s closed-loop gain is unaltered, the feedback available to correct distortion errors is reduced by 101, which means that measurement resolution increase ...
... inputs changes the amplifier’s noise gain. The result is that the error signal (distortion) is amplified by a factor of 101. Although the amplifier’s closed-loop gain is unaltered, the feedback available to correct distortion errors is reduced by 101, which means that measurement resolution increase ...
MAX1538 Power-Source Selector for Dual-Battery Systems General Description
... VCHGIN to GND .................................................-0.3V to +30V VADPPWR to GND...................................-0.3V to (VADPIN + 0.3V) VREVBLK, VADPBLK to GND ...................-0.3V to (VEXTLD + 0.3V) VCHGA, VCHGB, VDISBAT to GND ..........-0.3V to (VCHGIN + 0.3V) VDISA to GND..... ...
... VCHGIN to GND .................................................-0.3V to +30V VADPPWR to GND...................................-0.3V to (VADPIN + 0.3V) VREVBLK, VADPBLK to GND ...................-0.3V to (VEXTLD + 0.3V) VCHGA, VCHGB, VDISBAT to GND ..........-0.3V to (VCHGIN + 0.3V) VDISA to GND..... ...
Chapter 3 Special-Purpose Diodes
... The zener diode is a silicon pn junction devices that differs from rectifier diodes because it is designed for operation in the reverse-breakdown region. The breakdown voltage of a zener diode is set by carefully controlling the level during manufacture. The basic function of zener diode is to maint ...
... The zener diode is a silicon pn junction devices that differs from rectifier diodes because it is designed for operation in the reverse-breakdown region. The breakdown voltage of a zener diode is set by carefully controlling the level during manufacture. The basic function of zener diode is to maint ...
LT230 series Digital Indicating Controller
... Wires and crimping terminal covered by insulation sleeve ...
... Wires and crimping terminal covered by insulation sleeve ...
DRV8809, DRV8810 User`s Guide (Rev. A
... nSLEEP induces low power mode. It also serves the dual purpose of switching from setup mode and operational mode. These two modes differentiate on how the SPI ports and control signals behave. When nSLEEP is low, the SPI_AB port is enabled and allows the user to write to the SETUP and EXTENDED regis ...
... nSLEEP induces low power mode. It also serves the dual purpose of switching from setup mode and operational mode. These two modes differentiate on how the SPI ports and control signals behave. When nSLEEP is low, the SPI_AB port is enabled and allows the user to write to the SETUP and EXTENDED regis ...
DDA-3000 - Biddle Megger
... current measurement methods. By pressing the softkey directly beneath either PEAK or RMS, the user selects which calculation will be used in displaying measured current on the metering display. PEAK measures the highest peak and multiplies it by a constant 0.707. This method of measurement should in ...
... current measurement methods. By pressing the softkey directly beneath either PEAK or RMS, the user selects which calculation will be used in displaying measured current on the metering display. PEAK measures the highest peak and multiplies it by a constant 0.707. This method of measurement should in ...